• 제목/요약/키워드: Inductance calibration

검색결과 7건 처리시간 0.024초

Influence of Adaptor on the Calibration of Inductance Standards

  • Kassim, Dewi Mohd;Kim, Dan Bee;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.911-917
    • /
    • 2018
  • Influence of the adaptors on the calibration of $100{\mu}H$ inductance standard was studied as a function of torque, applied when tightening the standard inductor terminal with the adaptor. Two different homemade adaptors of BPO gold-plated brass (BPO-Au) and banana-copper (BN-Cu) were made for the connection between the LCR meter and the inductance standard. The measured inductance (L) of the standard inductor and the contact resistance ($R_C$) between the adaptor and the standard inductor terminal showed exponential decreases against the torque increase from $25cN{\cdot}m$ to $150cN{\cdot}m$. The measured L and the calculated equivalence series resistance ($R_S$) were dependent on the adaptor type as well as on the $R_C$. The results of the adaptor analysis imply that the BPO-Au adaptor with the lower $R_C$ is more suitable for the inductance calibration. The calculated inductance of $99.956{\mu}H$ corrected by subtraction of the adaptor inductance and the contact resistance contributions from the measured value using the BPO-Au adaptor agreed well with the certificate ($99.948{\mu}H$) of the PTB within the measurement uncertainty of $140{\mu}H/H$.

RF MEMS 인덕터의 특성 추출을 위한 De-embedding방법 (Accurate De-embedding Scheme for RF MEMS Inductor)

  • 이영호;김용대;김지혁;육종관
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.163-167
    • /
    • 2003
  • In this paper, an air-suspension type RF MEMS inductor is fabricated, and an appropriate de-embedding scheme for 3-dimenstional MEMS structure is applied and verified with inductance calculation algorithm. With the presented de-embedding method, parasitics from contanct pads and feeding lines are effectively and accurately de-embedded using open and short calibration procedure, and only spiral and posts can be characterized as a high-Q inductor structure. The validity of the de-embedding method is verified by the comparison of the measured and calculated inductances of two 1.5 and 2.5 turn square spiral inductors. The open-short de-embedded inductance error is below 5% each case in comparison with the calculated value based on H.M. Greenhouse's algorithm.

  • PDF

실리콘 기판상에서 나선형 인덕터의 최적설계 및 제작 (OPTIMAL DESIGN AND FABRICATION OF SPIRAL INDUCTOR ON SILICON SUBSTRATE)

  • 서종삼;박종욱이성희김영석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.645-648
    • /
    • 1998
  • We used a three-dimensional inductance extraction program, Fasthenry for optimal design of the spiral inductors on silicon substrate. The inductance and quality factor of the spiral inductors with various design parameters were calculated so that the optimal parameter value was determined. The spiral inductors then were fabricated using different foundary processes and were measured using the network analyzer and microwave probes. The pad and other parasitics of measurement system were de-embedded using the y-parameter calibration technique. the inductors fabricated using the LG 0.8um process and HP 0.5um process showed the quality factor of 5.8 and 3, respectively. Finally the equivalent circuit farameters of the spiral inductors on silicon substrate were extracted from the measurement data using the matlab.

  • PDF

교류저항 표준기 제작과 그 특성 (Development and Its Properties of Resistance Standards for Using Alternative Current)

  • 김한준;이상화;강전홍;유광민;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.267-268
    • /
    • 2009
  • Resistance standards from 1 ${\Omega}$ to 100 $k{\Omega}$, with calculable frequency dependencies of up to 1 MHz, have been developed for the calibration of commercial inductance-capacitance-resistance (LCR) meters and impedance analyzers. The resistors are designed on the basis of single bifilar loops. The typical resistance change from dc to 1 MHz is from 200 to $800\;{\mu}{\Omega}/{\Omega}$. According to the measurement results, the frequency dependencies of the resistors are severaltimes lower than the measurement uncertainty of commercial LCR meters.

  • PDF

로고우스키코일을 이용한 과도전류의 측정 (Measurement of Transient Current by using the Rogowski Coil)

  • 이복희;길경석;정승수;정상진
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1206-1213
    • /
    • 1994
  • This paper presents the operation principle and design rule of the Rogowski coil which can measure the transient current and describes the calibration and application experimental results for performance evaluation. It is obtained that the response curves of the Robowski coil with the turns of 300 and the passive integrator to sinusoidal input give a good linearity up to the frequency of 500 [kHz] and the current measurement system gaving the Rogowski coil is the frequency bandwidth of 40 [Hz]~700 [kHz]. As an application experiment for the fabricated modeling power transmission line, the impulse current, which limitates the direct lightning return stroke to overhead ground wire, is measured by the Rogowski coil and its fast Fourier transformation is carried out. The equivalent circuit of the Rogowski coil considering the stray capacitances is proposed, and the theoretical analysis is in good agreement with the measurement results. Also, it is found that for high frequency domain the stray capacitance such as a distributed capacitance to the shield and the capacitance between windings of coil should be considered in designing the Rogowski coils since the resonance originates from the stray capacitance and the self-inductance of the Rogowski coil.

  • PDF

전자장 유도 장치를 이용한 간척지 토양의 염농도 측정 (Use of Electromagnetic Inductance for Salinity Measurement in Reclaimed Saline Land)

  • 정영상;이원호;주진호;유일호;신완식;안열;류순호
    • 한국토양비료학회지
    • /
    • 제36권2호
    • /
    • pp.57-65
    • /
    • 2003
  • 본 연구는 간척지 토양에 대한 염류의 특성 및 분포를 비파괴 전자장 유도장치인 EM38을 이용하여 염류도의 공간변이성 및 분포도 작성을 수행하였다. 또한 EM38의 측정치를 깊이별 포화침출액의 ECe로부터 다중회귀방정식을 구하여 ECe의 값을 산정 하였다. 이러한 예측된 값으로부터 시험포장의 배수가 양호한 지역과 불량한 지역, 암거배수관이 설치된 지역의 염류도의 특성과 용탈층과 집적층의 구분의 활용성에 대해 조사를 수행하였다. 전자장 유도장치인 EM38의 수직적인 EMI측정값인 EMv와 수평적인 EMI측정값인 EMh값으로부터 분포도를 작성한 결과 시험포장의 특성을 정확히 구현할 수 있었다. 전자장 유도장치인 EM38의 수직적인 EMI 측정값인 EMv와 수평적인 EMI측정값인 EMh값을 지면으로부터 0, 10, 30 cm높이에서 측정한 결과 30 cm까지는 높은 상관관계를 보였으나, 50 cm이상에서는 상관관계를 보이지 않았다. 깊이별 가중치를 계산하여 얻은 ECgH, ECgV, ECgM의 값은 지면에서부터 높이 30 cm까지의 측정법에서는 매우 높은 상관관계를 보였고, 지면에서 측정한 EMv 와 EMh 의 ECgM의 회귀관계식이 가장 유의성 ($r2=0.753^{***}$)이 높은 것으로 나타났다. 예측치 회귀방정식 또한 지면으로부터 30 cm까지는 높은 상관관계를 보여주나 그 이상에서는 낮은 상관관계를 나타냈다.

전동력설비의 운전에 의해 발생되는 자계의 측정과 해석 (Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations)

  • 이복희;길경석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권2호
    • /
    • pp.58-67
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]~0.234[mV/$\mu$T]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

  • PDF