• 제목/요약/키워드: Induced Motive Force

검색결과 9건 처리시간 0.027초

Spin-Motive Force Caused by Vortex Gyration in a Circular Nanodisk with Holes

  • Moon, Jung-Hwan;Lee, Kyung-Jin
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.6-9
    • /
    • 2011
  • Spin-motive force has drawn attention because it contains a fundamental physical property. Spin-motive force creates effective electric and magnetic fields in moving magnetization; a vortex is a plausible system for observing the spin-motive force because of the abrupt profile of magnetization. However, the time-averaged value of a spin-motive force becomes zero when a vortex core undergoes gyroscopic motion. By means of micromagnetic simulation, we demonstrates that a non-zero time-averaged electric field induced by spin-motive force under certain conditions. We propose an experimental method of detecting spin-motive force that provides a better understanding of spin transport in ferromagnetic system.

Electric Field Induced by Spin-motive Force in a Perforated Nanodisk

  • Moon, J.H.;Lee, K.J.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2010년도 임시총회 및 하계학술연구발표회
    • /
    • pp.137-138
    • /
    • 2010
  • A model system allowing the experimental determination of the spin-motive force from the vortex gyration motion in a circular nanodisk is presented. It can be one way to get experimental detection of the spin-motive force and it will provide an important tool to study the relationship between the charge and spin transports in ferromagnetic system.

  • PDF

새 도선 감는 방법을 적용한 전기장 이용 스케일 제거 (Prevention of Particulate Scale with a New winding Method in the Electronic Descaling Technology)

  • 손창현;구상모;김창수;김건우
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.658-665
    • /
    • 2002
  • This paper presents a new winding method in electronic descaling (ED) technology. Conventional ED technology Produces an oscillating electric field via Faraday's law to provide the necessary molecular agitation to dissolve mineral ions. However, the proposed method produces an additional agitation force for mineral ions, called Lorentz's force. Experiments were performed using various Renolds numbers. A series of tests was conducted to measure the pressure drop across the test section and the overall heat transfer coefficient as a function of time. In order to accelerate the rate of fouling, artificial hard water, 1000ppm CaCO$_3$, was used throughout the tests. The results show that the new winding method accelerates the collision of the mineral ions, thereby improving the system efficiency. The present study can develope more effective fouling-removing equipment with change of estabishment method of coil.

22.9kV 배전선로와 병행하는 가스배관의 유도성 유도전압 해석 (Analysis of the induced voltage on the GAS pipelines buried in parallel with 22.9kV distribution line)

  • 이현구;하태현;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.130-132
    • /
    • 2002
  • Because of the continuous growth of energy consumption and also the tendency to site power lines and pipelines along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. Therefore there has been and still is a slowing concern about possible hazards resulting from the influence of power lines on metallic pipelines. Underground pipelines that run parallel to or in close proximity to power lines are subjected to induced voltages caused by the time-varying magnetic fields produced by the power line currents. The induced electro- motive force cause currents circulation in the pipeline and voltages between the pipeline and surrounding earth. This paper analyzes the induced voltage on the gas pipelines buried in parallel with 22.9kV distribution lines. Their magnitude depends on the length of parallelism and on the distance between distribution lines and pipeline.

  • PDF

응력확대계수측정을 위한 하중에 의한 자속밀도변화의 실험적 연구 (Experimental Research of Change in Magnetic Flux Density Due to Load for Measuring KI)

  • 이정희
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.129-132
    • /
    • 2004
  • In order to determine the effective way of measuring the Mode I stress intensity factor, $K_I$, by means of the alternating current potential drop(ACPD) technique for a material containing a two-dimensional surface crack, the change in magnetic flux density above the cracked specimen surface was studied experimentally. The change in magnetic flux in the air above the cracked specimen made of aluminum alloy is measured by changing the load by four-point bending. The magnetic flux in the air is almost not changed by increasing the load in teh specimen. The change in potential drop due to load is not caused by the change in electro-motive force induced in the coiled measuring system. This experimental result agree to the result of theoretical analysis in reference 7).

  • PDF

고속 솔레노이드 액츄에이터의 특성 해석 (Chracteristics Analysis of High-Speed Solenoid Actuator)

  • 성백주;이은웅;김형의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.962-964
    • /
    • 2004
  • The plunger speed of solenoid actuator is affected by mass of plunger, magnetic motive force, inductance, and return spring. These factors are not independent but related with each other according to design characteristics of solenoid actuator. So, it is impossible to change the designed value for the purpose of increasing plunger speed. In this study, we have analyzed the characteristics of high-speed solenoid actuator having a non-magnetic ring which plays a role to concentrate the effective magnetic flux into plunger. For more detailed analysis, we have induced characteristic equations and performed FEM analysis and simulation for dynamic characteristics of plunger, and proved the propriety of these by experiments.

  • PDF

3D Transient Analysis of Linear Induction Motor Using the New Equivalent Magnetic Circuit Network Method

  • Jin Hur;Kang, Gyu-Hong;Hong, Jung-Pyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권3호
    • /
    • pp.122-127
    • /
    • 2003
  • This paper presents a new time-stepping 3-D analysis method coupled with an external circuit with motion equation for dynamic transient analysis of induction machines. In this method, the magneto-motive force (MMF) generated by induced current is modeled as a passive source in the magnetic equivalent network. So, by using only scalar potential at each node, the method is able to analyze induction machines with faster computation time and less memory requirement than conventional numerical methods. Also, this method is capable of modeling the movement of the mover without the need for re-meshing and analyzing the time harmonics for dynamic characteristics. From comparisons between the results of the analysis and the experiments, it is verified that the proposed method is capable of estimating the torque, harmonic field, etc. as a function of time with superior accuracy.

와전류의 영향을 고려한 솔레노이드 액츄에이터의 동작특성 해석 (Analysis of Operational Characteristic for Solenoid Actuator Considering Eddy Current Effects)

  • 성백주;이은웅;김형의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.816-818
    • /
    • 2003
  • Solenoid actuator's operating speed is affected by magnetic motive force, plunger mass, inductance, return spring constant, and eddy current. Recently, non-magnetic ring is generally used for improving the operational speed, because it is impossible that changing of any specified design factor and stacking of plunger steel. This paper represents the dynamic equations of solenoid actuator, simulations for the response characteristics, analysis of eddy current effect by using the induced time constant. And, we experiment for the operating characteristics in case of non-magnetic ring is exists and not exists in the plunger.

  • PDF

Study of changes in the kinetic parameters of corrosion on the macrocell current induced by the repair of reinforced concrete structures - Results of numerical simulation

  • Mostafa Haghtalab;Vahed Ghiasi;Aliakbar Shirzadi Javid
    • Computers and Concrete
    • /
    • 제32권3호
    • /
    • pp.287-302
    • /
    • 2023
  • Corrosion of reinforcing bars in reinforced concrete structures due to chloride attack in environments containing chloride ions is one of the most important factors in the destruction of concrete structures. According to the abundant reports that the corrosion rate around the repair area has increased due to the macro-cell current known as the incipient anode, it is necessary to understand the effective parameters. The main objective of this paper is to investigate the effect of the kinetic parameters of corrosion including the cathodic Tafel slope, exchange current density, and equilibrium potential in repair materials on the total corrosion rate and maximum corrosion rate in the patch repair system. With the numerical simulation of the patch repair system and concerning the effect of parameters such as electromotive force (substrate concrete activity level), length of repair area, and resistivity of substrate and repair concrete, and with constant other parameters, the sensitivity of the macro-cell current caused by changes in the kinetic parameters of corrosion of the repairing materials has been investigated. The results show that the maximum effect on the macro-cell current values occurred with the change of cathodic Tafel slope, and the effect change of exchange current density and the equilibrium potential is almost the same. In the low repair extant and low resistivity of the repairing materials, with the increase in the electromotive force (degree of substrate concrete activity) of the patch repair system, the sensitivity of the total corrosion current reduces with the reduction in the cathode Tafel slope. The overall corrosion current will be very sensitive to changes in the kinetic parameters of corrosion. The change in the cathodic Tafel slope from 0.16 to 0.12 V/dec and in 300 mV the electromotive force will translate into an increase of 200% of the total corrosion current. While the percentage of this change in currency density and equilibrium potential is 53 and 43 percent, respectively. Moreover, by increasing the electro-motive force, the sensitivity of the total corrosion current decreases or becomes constant. The maximum corrosion does not change significantly based on the modification of the corrosion kinetic parameters and the modification will not affect the maximum corrosion in the repair system. Given that the macro-cell current in addition to the repair geometry is influenced by the sections of reactions of cathodic, anodic, and ohmic drop in repair and base concrete materials, in different parameters depending on the dominance of each section, the sensitivity of the total current and maximum corrosion in each scenario will be different.