• 제목/요약/키워드: Indoor-Unit

검색결과 337건 처리시간 0.029초

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

Effect of Polycarbonate Covering Sheet on Greenhouse Indoor Environments and Growth Behavior of Cherry Tomatoes

  • Choi, Kyung Yun;Kim, Soo Bok;Bae, Seokhu;Yoon, Jeong-Hwan;Yun, Ju-Ho;Kim, Namil
    • Elastomers and Composites
    • /
    • 제55권2호
    • /
    • pp.114-119
    • /
    • 2020
  • The effect of a greenhouse-covering material on its indoor environment and on the characteristics of cherry tomatoes grown in it was investigated. The conventional polyethylene (PE) film on the greenhouse roof was replaced by a polycarbonate (PC) sheet, while maintaining the main structural frame intact. Color changes and the formation of water droplets on the PC surface were avoided by applying coextrusion and coating layers. When compared to the PE greenhouse, the PC greenhouse enabled increased light transmittance and thus a higher indoor temperature during both summer and winter. The thermal insulating property of the PC sheet effectively reduced the heating loss by approximately 55% during winter. The cherry tomatoes grown in the PC greenhouse exhibited superior fruit characteristics in terms of size, weight, and sugar content. The total amount of cherry tomatoes produced per unit area (1,000 ㎡) in the PC greenhouse was found to be greater by approximately 19% compared to that in the PE greenhouse.

Improved Georeferencing of a Wearable Indoor Mapping System Using NDT and Sensor Integration

  • Do, Linh Giang;Kim, Changjae;Kim, Han Sae
    • 한국측량학회지
    • /
    • 제38권5호
    • /
    • pp.425-433
    • /
    • 2020
  • Three-dimensional data has been used for different applications such as robotics, building reconstruction, and so on. 3D data can be generated from an optical camera or a laser scanner. Especially, a wearable multi-sensor system including the above-mentioned sensors is an optimized structure that can overcome the drawbacks of each sensor. After finding the geometric relationships between sensors, georeferencing of the datasets acquired from the moving system, should be carried out. Especially, in an indoor environment, error propagation always causes problem in the georeferencing process. To improve the accuracy of this process, other sources of data were used to combine with LiDAR (Light Detection and Ranging) data, and various registration methods were also tested to find the most suitable way. More specifically, this paper proposed a new process of NDT (Normal Distribution Transform) to register the LiDAR point cloud, with additional information from other sensors. For real experiment, a wearable mapping system was used to acquire datasets in an indoor environment. The results showed that applying the new process of NDT and combining LiDAR data with IMU (Inertial Measurement Unit) information achieved the best result with the RMSE 0.063 m.

농촌공동주택 단위공간내 주생활방식에 관한 조사연구 (A Study of the Living Modes in the Unit Spaces of the Rural Apartment Houses)

  • 민양관;조일환;최효승
    • 한국농촌건축학회논문집
    • /
    • 제1권2호
    • /
    • pp.39-51
    • /
    • 1999
  • This study aims to obtain new design factors in terms of constructing rural apartment houses fit for the actual farm life. To carry out this study, field studies and personal interviews have been made on the living mode and using realities in the unit spaces of the rural apartment houses. The houses surveyed are the rural apartments in Chungbuk Province which were built by the public program to improve old farm houses. The results are as follows. The living modes .in the unit spaces of the rural apartments are very similar to those of the urban apartment houses. But compared with the urban indoor-living modes, the rural life is keeping more of the traditional sitting way-of-living. Accordingly, it is quite necessary to consider the nature of farm life and the sitting way-of-living in designing the rural apartment houses.

  • PDF

지역냉방 공동주택 적정 냉방부하 산정 (The Estimation of Cooling Load for District Cooling in Apartment Buildings)

  • 김상훈;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.643-649
    • /
    • 2008
  • The purpose of this study is to establish a standard for unit cooling load in central control type apartment applied district cooling. The model of unit household was selected. And the standard of coefficient of overall heat transmission, location of unit household, indoor air temperature, solar radiation & thermal conduction at window and interior load was selected, and region, expansion or non-expansion of balcony, pyeong type, azimuth, rate of window area was applied as parameter. And then cooling load simulation was performed. Based on the result of simulation, the synthetic district cooling load was presented for selecting heat source of apartment applied district cooling, and unit cooling load was analyzed according to design parameter.

  • PDF

이동형 음압기를 적용한 긴급 전환형 임시음압격리병실의 실내 환경 측정 분석 (Measurement and Analysis of Indoor Environment in Emergency Switching Type Temporary Negative Pressure Isolation Ward that Use Portable Negative Pressure Units)

  • 이원석;이세진;김희강;여명석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권4호
    • /
    • pp.89-97
    • /
    • 2022
  • Purpose: Because of the recent COVID-19 pandemic, there have been many cases of using portable negative pressure unit to convert general wards into temporary negative pressure isolation wards. The purpose of this study is to analyze the indoor environment of the switching type wards. Methods: Field measurements and experiments were conducted in a medical facility. Air volume, wind speed and pressure difference were measured in non-occupant state. Dispersion tests were performed with gas and particle matter. Results: The pressure difference between the wards and the corridor was higher than -2.5 Pa in normal situation. However, in the gas and particle dispersion tests, it was found that there were concerns about the spread through leakages in low-airtight walls or ceilings. In addition, it was confirmed that the pressure imbalance in ducts through the non-sealed diffusers could cause back flow during portable unit operation. Furthermore, when there was a pressure difference between adjacent wards planned to be at same pressure level, the possibility of the spread through the leakages was found. Implications: When using portable units for making switching type wards, it is necessary to create airtight space and seal the non-operation diffusers. In case of operating the air handling unit, T.A.B must be performed to adjust the duct balancing.

실내 공기 중 일부 알데하이드류에 대한 위해도 평가 - 일부 주택 및 아토피 환자 주택을 대상으로 (Risk Assessment of Aldehydes in Some Residential Indoor Air Included Atopy Patient's Homes)

  • 문경환;변상훈;최달웅;이은일;오은하;김영환
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.19-26
    • /
    • 2006
  • This study was undertaken to determine the concentrations of 15 aldehydes in air samples collected from 21 households including 9 atopy patient's homes and to assess the extent of exposure and risk for an individual due to inhalation. Of all the aldehydes identified in both indoor and outdoor environment, formaldehyde and acetaldehyde were the most abundant aldehydes, which were occupied $60\%\;and\;17\%$ of total amount, respectively. The geometric mean concentration of formaldehyde and acetaldehyde in indoor air were $170.5\pm1.9\;{\mu}g/m^3\;and\;47.3\pm1.5\;{\mu}g/m^3$, respectively. There existed a strong correlation between formaldehyde, acetaldehyde and other aldehydes. And the ratio of indoor and outdoor concentrations (I/O) exceeded 1.0 for almost every measured aldehydes except m-tolualdehyde... No associations were found between the level of aldehydes and either housing characteristics or living habits in most of the samples with only a few exception. And the concentrations of all aldehydes indoor air between atopy patient's homes and control homes were not significant(p>0.05). Formaldehyde and acetaldehyde exposures and risks were estimated by using the inhalation unit risk, mean concentrations and the 95th percentiles, and which were $2.6\times10^{-3}\;and\;1.1\times10^{-4}$, respectively. The mean and the 95th percentile risk estimates were 25 times higher for formaldehyde than for acetaldehyde in homes.

ISO 12219-5 (Static chamber법)를 이용한 모듈내 구성부품별 VOCs 영향도 분석 (VOCs impact factor analysis of unit components in Part assembly by ISO 12219-5 method)

  • 이신종;장혜진;곽동환;김만구
    • 분석과학
    • /
    • 제27권6호
    • /
    • pp.284-291
    • /
    • 2014
  • 차량 실내 공기질 대응 프로세스는 두 단계의 시험 방법으로 이루어져 있다. 먼저 모듈 부품평가를 통해 차량 실내 VOCs의 주요 원인을 찾고, 절단 시험편을 이용하여 VOCs가 주로 방출되는 소재를 찾는다. 만약 VOCs가 주로 방출되는 소재를 확인 시, 소재 개선을 통해 차량과 모듈 부품에서 방출되는 VOCs를 줄일 수 있다. 하지만 기존의 절단 시험편을 이용한 시험법은 VOCs 원인을 찾는데는 절단면에서의 방출 문제가 있기 때문에, 구성 부품 단위의 평가방법 적용이 필요하다. ISO 12219-5 시험 방법은 부품 절단없이 평가를 하기 때문에 소재 및 표면적의 영향이 함께 고려되어, 모듈 부품에서 구성 부품의 VOCs 영향도 확인이 가능하였다. 트림과 콘솔의 구성부품 평가를 통해 모듈내의 주요 원인 부품을 확인할 수 있었다. 또한 ISO 12219-5 모듈 부품 시험법과 구성 부품 시험법간의 정량적 상관관계 규명을 통해 품질관리를 위한 관리값을 설정할 수 있었다.

Operation Results and Utility of Dynamic Pricing Response Control-Applied VRF System in Summer Season

  • Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • 제19권3호
    • /
    • pp.71-77
    • /
    • 2017
  • Dynamic pricing refers to a system in which a tariff varies, according to a level of charging and applied time depending on time change. The power billing system used in the Korean Electric Power Corporation (KEPCO) is based on time of use (TOU) pricing, which is one of the dynamic pricing systems. This paper aimed to determine the operational results of a variable refrigerant flow system, to which a new control algorithm was applied, in order to respond to dynamic pricing, in summer and the utility of the new control. To do this, real measured data was acquired from a VRF system installed in a building for educational purposes, where dynamic pricing was applied for about 100 days during summer time. At the maximum load operation time period in TOU, the new control minimized operation within the indoor comfort range, an increase in refrigerant evaporation temperature in the indoor unit and the number of revolutions in a compressor in the outdoor unit was limited. As a result, power usage was decreased by 11%, and the operational cost by 14.6%. Furthermore, measurement results using the Predicted Mean Vote (PMV) model, that represented satisfaction of thermal environment, showed that 82.8% to 90.4% of the occupants of the building were satisfied during operation when the new control was applied.

농작업자 자동 추종 운반차 개발(I) - 시작기 제작 및 실내성능시험 - (Development of an Autonomous Worker-Following Transport Vehicle (I) - Manufacture and indoor experiment of the prototype vehicle -)

  • 권기영;정성림;강창호;손재룡;한길수;정석현;장익주
    • Journal of Biosystems Engineering
    • /
    • 제27권5호
    • /
    • pp.409-416
    • /
    • 2002
  • This study was conducted to develop a vehicle, leading or following a worker at a certain distance to assist laborious transporting works in greenhouses. A prototype vehicle, which consisted of the rear driving, the front steering and the console units, was designed and tested in the ideal indoor conditions. Results of this study were summarized as following: 1. The driving unit was designed to travel at the speed ranges of 0.3∼0.8 m/sec depending on the operating modes with a maximum payload of 100 kg. 2. The console unit consisted of a main-board including a 80C196KC microprocessor and peripheral devices, a power-board and safety interlock. Worker-leading, and following modes were available in automatic and manual modes. 3. Steering was achieved by turning the steering motor against the sensed direction. Proper steering angles for correcting travel direction were determined as 5 and 9 degrees when sensing cultivation beds and plants, respectively.