• 제목/요약/키워드: Indoor load

검색결과 260건 처리시간 0.026초

실물실험을 통한 다이나믹 유량밸런싱 적용 공동주택 세대의 에너지소비량 평가 (Evaluation of Energy Consumption through Field Measurement at the Apartment Housing Unit Using Dynamic Flow Rate Balancing)

  • 류성룡;정창헌;조현
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.15-20
    • /
    • 2016
  • Even though the control device of the heating system works well, insufficient water flow rates can degrade control performance and thermal comfort. The water flow rate should be adjusted appropriately to cope with the heating load of each zone. In order to solve these problems, a new balancing concept 'dynamic balancing' was proposed where a balancing valve opening can be automatically modulated according to the heating condition of the room. This study analyzed the effects of dynamic balancing upon indoor thermal environment and energy consumption in a radiant floor heating system through field measurement. Under part-load conditions, the use of a dynamic balancing is a more effective method to reduce energy consumption and to prevent a cavitation. Dynamic balancing is able to help boost the temperature of a room in the start-up period.

트랙터의 기관속도 및 변속비의 최적제어에 관한 연구(II) -최적운전 제어 시스템의 성능- (Automatic Control of Engine Speed and Transmission Ratio for Efficient Tractor Operations(II) -Performance of Optimal System-)

  • 강성봉;류관희;오길근
    • Journal of Biosystems Engineering
    • /
    • 제19권4호
    • /
    • pp.291-300
    • /
    • 1994
  • It is desired to operate tractor engines at or near maximum torque much of the time in field operation to increase fuel efficiency. To do this it is necessary to reduce engine speed and to shift gears to higher ratios as frequently as possible. Because of load variations in most drawbar work and inconvenience in gear shift, however, gear-type transmission are usually set in one ratio at unnecessarily high engine speeds, and engine-torque variations are used to compensate for changes in drawbar load. As a result, the most of time the tractor is not operated efficiently in terms of fuel consumption and work output. The objective of this study was to develop an automatic control system which is able to operate a tractor equipped with gear transmission under the optimal condition in terms of fuel efficiency with automatic governor setting and gear shift. An indoor experimental test set which can be used to simulate tractor operation, control engine speed and transmission ratio was developed in the previous paper. In this paper, the performance of the optimal operation system is reported. Through a series of tests, it was found that the automatic control system for optimal operation of tractors with gear transmission had a satisfactory performance.

  • PDF

미소 루프 마이크로스트립 안테나 (A Microstrip Antenna with a Small Loop)

  • 고영혁;박수봉;류현
    • 한국전자파학회논문지
    • /
    • 제8권4호
    • /
    • pp.354-362
    • /
    • 1997
  • 본 논문에서 용량을 장하하기 위해 좌.우측 평행 평판을 구성한 미소 루프 마이크로스트립 안테나를 제안했다. 제안된 안테나는 용량을 장하하기 위해서 QMSA(Quarter-Wavelength Micorostrip Antenna)에 오른쪽 평행 평판을 구성한 안테나보다 개선된 높은 이득과 대역폭을 얻었다. 또한, 설계. 제작된 안테나는 동작 주파수가 1.5GHz에서 수직 수평 편파를 수신할 수 있다. 그러므로 이 안테나는 무선 전화를 위한 소형화된 안테나로 이용할 수 있고 실내 통신을 위해 아주 유용하다.

  • PDF

해외 주요 도시의 기후특성에 따른 최대공조부하 요소별 분석 (Heating and Cooling Load according to the Climatic Conditions of Foreign Cities)

  • 안승현;김종호;이정훈;이상엽;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.81-87
    • /
    • 2014
  • According to the domestic construction business will continue stagnant, many domestic construction companies are expanding their business into foreign countries. As results, building design guidelines including HVAC design for foreign countries considering the regional climate conditions are needed. Also, green building design strategies to minimize the heating and cooling load are key issue to win a contract in construction business in the world. In this study, peak heating and cooling loads were calculated for the representative cities in the world : Seoul, St. Petersburg, Singapore and Mecca. The analyzed building was a typical high-rise office building and the building envelope properties, indoor heat gain, residence and operating schedules were same in all cases. Only the weather conditions were different by cases.

Energy Saving Potentials of Ventilation Controls Based on Real-time Vehicle Detection in Underground Parking Facilities

  • Cho, Hong-Jae;Park, Joon-Young;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.331-340
    • /
    • 2013
  • The main topic of this paper is to show a possibility of indoor air quality enhancement and the fan energy savings in underground parking facilities by applying the demand-controlled ventilation (DCV) strategy based on the real-time variation of the traffic load. The established ventilation rate is estimated by considering the passing distance, CO emission rate, idling time of a vehicle, and the floor area of the parking facility. However, they are hard to be integrated into the real-time DCV control. As a solution to this problem, the minimum ventilation rate per a single vehicle is derived in this research based on the actual ventilation data acquired from several existing underground parking facilities. And then its applicability to the DCV based on the real-time variation of the traffic load is verified by simulating the real-time carbon monoxide concentration variation. The energy saving potentials of the proposed DCV strategy is also checked by comparing it with those for the current underground parking facility ventilation systems found in the open literature.

건물예냉과 실내온도의 선형상승에 의한 피크냉방수요 저감 (Reducing Peak Cooling Demand Using Building Precooling and Modified Linear Rise of Indoor Space Temperature)

  • 이경호;양승권;한승호
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.86-96
    • /
    • 2010
  • The paper describes development and evaluation of a simple method for determining gradient of modified linear setpoint variation to reduce peak electrical cooling demand in buildings using building precooling and setpoint adjustment. The method is an approximated approach for minimizing electrical cooling demand during occupied period in buildings and involves modified linear adjustment of cooling setpoint temperature between $26^{\circ}C$ and $28^{\circ}C$. The gradient of linear variation or final time of linear increase is determined based on the cooling load shape in conventional cooling control having a constant setpoint temperature. The potential to reduce peak cooling demand using the simple method was evaluated through building simulation for a calibrated office building model considering four different weather conditions. The simple method showed about 30% and 20% in terms of reducing peak cooling demand and chiller power consumption, respectively, compared to the conventional control.

식물공장 이중창호의 하절기 열전달 성능 분석 (Performance Analysis of Summertime Heat Transfer Characteristics of the Double Skin Window for Plant Factory)

  • 소재현;김우태
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.351-357
    • /
    • 2012
  • To reduce the summertime cooling load of a plant factory, a concept design was performed for the double skin window which utilizes the low temperature air from a ground coupled heat exchanger. The design parameters were selected as the number of cavity air inlet, the cavity thickness, the location of cavity air inlet, and the configuration of cavity air outlet. A parametric study was conducted in a systematic way to evaluate the heat transfer characteristics of the double skin window. As the number of cavity air inlet and the cavity thickness increase, the heat flux from outside air to indoor air was decreased. The effect of the location of cavity air inlet was not significant and the larger cavity air outlet area gave us relatively better heat blocking performance from outside hot air. This study demonstrated that it is possible to develop an improved double skin window by utilizing a ground coupled heat exchanger.

교실에 설치된 블라인드의 유형과 색상에 따른 실내 온열환경 평가 (Evaluation of Indoor Thermal Environment according to Type and Color of Blinds Installed in the Classroom)

  • 권대혁;이재로;오주석;위승환;김수민
    • 한국가구학회지
    • /
    • 제28권3호
    • /
    • pp.224-232
    • /
    • 2017
  • Building energy saving have been put effort in a long time since buildings consume about 40.6% of total energy use, where heating, cooling and electrical lighting requirement results in energy consumption of building significantly. The window is an important part of building envelope, it usually brings a certain heat load from solar radiation while it allows light passing through, and properly leads to overheating in summer, hence the cooling load increase sand cause of thermal uncomfortable factor. The purpose of this study was to evaluate internal shade performance according to color and materials. There is growing interest in improving the sense of comfort among students who spend most of their time in the classroom. The study examined thermal environment and light environmental performance according to the color and materials of internal blinds to the school classroom. The results of this study were as follows; Among wooden blinds, aluminium blinds, and polyester blinds, the aluminium blinds were most excellent. In addition, among white blinds, light brown blinds, dark brown blinds, the light brown were most excellent.

화재피해를 받은 철근콘크리트 건축물의 기둥의 영향인자를 고려한 해석적 연구 (Numerical Study on the Fire Damaged Reinforced Concrete Building Structures Considering Influencing Fire Case and Parameters of Columns)

  • 서연우;손희주
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.101-112
    • /
    • 2022
  • Expanding urbanization practices result in high numbers of buildings being developed in city centers. This high building concentration leads to an increased fire risk, resulting in higher casualty rates and increased economic damages compared to fires in the past. The purpose of this study was to analyze the structural behavior of fire-damaged reinforced concrete buildings using analytical methods and to suggest methods of improving fire resistance in the event of a fire. Damage levels were measured using commercial software to apply the finite element method, ABAQUS, and MIDAS GEN to the dataset. Load-deflection curves were calculated using the effective area and moment of inertia of the fire-damaged columns provided by ABAQUS. The results of this analysis indicate that fire-damaged beams with experience greater deflection from indoor fires than they will from outdoor fires. Fires that occurred on the middle floors were more dangerous than those occurring on higher floors, and eccentrically loaded columns experienced more damage than axially loaded columns. The results indicate that these methods accurately predict structural behaviors of fire damaged concrete columns by considering fire exposure area and eccentric loading.

온실내 근권부의 지중냉각부하 추정 (Estimation of Soil Cooling Load in the Root Zone of Greenhouses)

  • 남상운
    • 생물환경조절학회지
    • /
    • 제11권4호
    • /
    • pp.151-156
    • /
    • 2002
  • 지중냉각이나 양액냉각과 같은 근권부 냉각은 뿌리의 활력 증진, 양수분 흡수력의 향상, 작물체온의 강하 및 고온스트레스의 감소 등에 효과가 있는 것으로 알려져 있으며, 또한 온실 전체를 냉방하는것 보다 경제적이다. 따라서 본 연구에서는 지중냉각시스템을 경제적인 고온극복 방법중의 하나로 생각하고, 기술을 체계화하기 위한 시도로 지중냉각시스템의 열전달 특성을 분석하여 냉각부하를 산정하기 위한 실험을 수행하였다. 지중열류 측정자료로부터 힘수비에 따른 토양의 열전도율을 분석하였으며, 함수비 19~36%의 범위에서 열전도율은 0.83~0.96W.m$^{-}$.$^{\circ}C$$^{-}$로 직선적인 증가를 보였다. 일사량, 지표온도 및 기온의 관측치로부터 일사량에 따른 지표온도 상승을 회귀분석한 결과 거의 직선적인 관계를 보였으며, 지표온도는 실내 수평면 일사량 300~800W.m$^{-2}$ 범위에서 작물이 없는 경우 3.5~7.$0^{\circ}C$,작물이 지표면을 거의 덮고 있는 경우 1.0~2.5$^{\circ}C$ 정도 기온보다 상승하는 것으로 나타났다. 실험자료를 이용하여 온실의 설계기온과 냉각설정 지온, 일사량 및 토양의 함수비에 따른 지중냉각시스템의 냉각부하를 구하였다. 실내일사량 300~600W.m$^{-2}$ , 토양함수비 20~40%의 범위에서 기온과 지온의 차이를 1$0^{\circ}C$로 유지하기 위해서는 46~59W.m$^{-2}$ 의 냉각열량이 필요한 것으로 나타났다. 보다 정확한 설계자료의 구축을 위해서는 다양한 조건별 실험을 추가로 수행해야 할 것으로 생각된다.EX>$\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.加的)으로 되거나 과가황(過加黃)이 될 우려가 있는 제조공정(製造工程)에서는 흔히들 이 방법(方法)을 무시(無視)하고 있다. 여기서 강조(强調)해 두어야 할 것은 항상 제품(製品)의 외부(外部)를 완전(完全)히 가황(加黃)시킬 필요(必要)는 없다는 것이다. 다공성(多孔性)이나 기포생성(氣泡生成)을 조장(助長)하는 불량가황상태(不良加黃狀態)와 표면(表面)에서의 과가황상태간(過加黃狀態間)의 균형(均衡)을 취(取)해 줘야 하는데 물론(勿論) 이때는 가황시간(加黃時間)을 단축(短縮)시켜야 한다는 경제적(經濟的)인 측면(側面)도 아울러 고려(考慮)해야 한다. 이것은 고무기술자(技術者)가 당면(當面)해야할 과제(課題)