• Title/Summary/Keyword: Indoor environmental factors

Search Result 292, Processing Time 0.027 seconds

Analysis of Exposure Characteristics and Exposure Rating of Participants with Injuries from CMIT/MIT Humidifier Disinfectants (CMIT/MIT 가습기살균제 사용에 따른 피해구제 신청자의 노출등급 및 노출특성 분석)

  • Gihong Min;Junghyun Shin;Eun-Kyung Jo;Seula Lee;Jihun Shin;Dongjun Kim;Jaemin Woo;Yoon-Hyeong Choi;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.3
    • /
    • pp.169-177
    • /
    • 2023
  • Background: The Korea Centers for Disease Control and Prevention (KCDC) has identified cases of people suspected of suffering lung disease potentially caused by chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) used in humidifier disinfectants (HDs). The Korean Ministry of Environment (MoE) epidemiological investigation and toxicity test study found that HDs caused health damage such as asthma and lung disease. Objectives: The main purposes of this study were to classify the HD exposure rating and to analyze the exposure characteristics that affect exposure to CMIT/MIT HDs. Methods: The exposure characteristics and socio-demographic characteristics of victim participants using CMIT/MIT HDs were investigated through questionnaires. An inhalation no observed adverse effect level (NOAEL) for CMIT/MIT was produced based on inhalation toxicity values. Exposure ratings (class 1~class 2) were cross-tabulated with clinical ratings (acceptable~unacceptable). A correlation analysis was conducted with the main exposure characteristics that affect the exposure concentration of CMIT/MIT HDs. Results: The concentration in indoor air of CMIT/MIT was 8.75±25.40 ㎍/m3, and the exposure concentration was 2.30±6.29 ㎍/m3. The CMIT/MIT exposure rating of 67 participants with high exposures of not more than MOE 100 were evaluated as 14.5%, while the damage participants who matched the clinical rating made up 4.5%. The exposure concentration of CMIT/MIT showed a positive correlation with the daily usage amount and usage frequency, and a negative correlation with volume of the indoor environment. Conclusions: A new exposure rating could be suggested and calculated based on the MOE, and the factors affecting the exposure concentration could be identified.

A Investigation of On-board Thermal Factor (함정 선내의 온열요소에 대한 조사 연구)

  • Jang M.S.;Koh C. D.;Moon I. S.;Lee C. J.;Kim S. H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.1
    • /
    • pp.31-38
    • /
    • 2005
  • This paper is focused on the research of environmental and human factors for a design of PMVbased air conditioning system in the ship. In the results from environmental factor research, it is possible to dissatisfy thermally in the wheel house and communication room of 25 ton and engine room of 100 ton. The clothing and activity in the ship is modified using inland indoor characteristics. Thermal resistance of clothing may be more sensitive to PMV(predicted mean vote) than metabolic rate because of large deviation among maritime polices. The distribution of human factor is right long-tailed than standard normal distribution.

  • PDF

How do they Make Libraries Green?: A Case Based Study on Building Green Libraries (녹색도서관 사례분석을 기반으로 한 국내 녹색도서관 구축방향에 관한 연구)

  • Ahn, In-Ja;Kwak, Chul-Wan;Noh, Young-Hee;Park, Mi-Young
    • Journal of Information Management
    • /
    • v.43 no.1
    • /
    • pp.135-158
    • /
    • 2012
  • Since the 1990s, discussions regarding green libraries started in the U.S.A, in the name of 'library and the environment', 'Green librarians', 'constructing of environmental sources', 'noise and library', 'building libraries as an environmental alternative' and etc. Currently, green libraries certified by an evaluation system are more than 50. This study proposes a direction to build a green library. The study analyzes national and international green libraries certified by the evaluation system. The cases are analyzed based on the six evaluation factors in the LEED certification system; Sustainable Site, Water Efficiency, Energy and Atmosphere, Material and Resources, Indoor Environmental Quality, Innovation and Design Process. Since the evaluation system focuses mainly on the architectural aspects, there was a need of expanding the concept of eco-friendly in this research. The newly expanded eco-friendly concept includes services, content, and supplies of libraries.

The Effect of Dissolved Oxygen on the Estival Mass Mortality of sea squirt, Halocynthia roretzi(Drasche) (여름철 우렁쉥이 대량폐사에 대한 용존산소의 영향)

  • NA Gui-Hwan;LEE Chae-Sung;CHOI Woo-Jeung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.24 no.1
    • /
    • pp.52-58
    • /
    • 1991
  • Mass mortality of Halocynthia roretzi has been occurred in culturing grounds of southern coast of Korea during the long period of summer drought and the unusal high water temperature in 1988. Especially Halocynthia roretzi was damaged severely in 2 years group. Therefore we verified these phenomena by observing the environmental factors of culturing grounds and by evaluating oxygen consumption rate in indoor experiment. In culturing grounds, the mortality rate was high in Namhae Mizo area where water temperature was the highest and the lowest in dissolved oxygen concentration as low as 3.76m/l in field observation. In indoor experiment, the higher the water temperature, the more mortality was occurred and the salinity above 30 had no effect on its mortality. In oxygen consumption rate experiment, the smaller needs more oxygen than larger one, i. e., oxygen demand per unit weight was higher in 2 years group than that of 3 years. The theoretical and the actual minimum oxygen demands(MOB) for preventing asphixation was 3.7ml/kg/h at $20^{\circ}C$ and 6.3ml/kg/h gat $25^{\circ}C$, But actual MOD was 4.3ml/kg/h at $25^{\circ}C$ in indoor experiment. It seemed that mass mortality of Halocynthia roretzi in summer was caused by metabolism disorder due to insufficient oxygen level influenced by the high water temperature and the high density of Halocynthia roretzi, which results in the paucity of oxygen especially in 2 years groups.

  • PDF

A Study on the Housing Choice Behavior of Residents the Plan of Apartment in New Housing Area, Ulsan (울산시 신주거지의 아파트 계획을 위한 거주자 주거선택행동에 관한 연구)

  • Kim Sun-Joong;Kwon Myung-Hee
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.1-13
    • /
    • 2006
  • The purpose of the study was to identify the level of housing choice behavior by using the factors of residential satisfaction level, mobility motivation, and housing needs of potential purchasers in Bukgu New Housing Area, Ulsan. The survey used questionnaire from 326 households living in Bukgu and nearby area and analyzed using descriptive statistics. The research results showed low degree of residential satisfaction in storage space and neighborhood. The mobility motivations were improvement of physical environment improvement, education environment, walking road, view and lighting. The housing needs for indoor spaces showed to want more functional arrangement than the room size. The housing needs for outdoor spaces showed to want neighborhood environment in connection with the education or hospital facilities, the welfare facilities for pre-kindergarten children and elders and the leisure facilities. And the housing needs for facilities were floor furnishing for health, crime prevention system for safety needs, housekeeping appliance against environmental pollution, additional function for energy saving. The housing needs for common spaces showed that the residents preferred playing facilities by age group, exercise facilities, the community hall and the rest room which can do games or meetings.

Efficiency Evaluation of Adsorbents for the Removal of VOC and NO2 in an Underground Subway Station

  • Son, Youn-Suk;Kang, Young-Hoon;Chung, Sang-Gwi;Park, Hyun-Ju;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2011
  • Adsorbent combination studies have been carried out to remove nitrogen dioxide ($NO_2$) and volatile organic compounds (VOCs: BTEX) out of a subway environment characterized by high flow and low concentration. Optimal conditions for the high removal efficiency of the concerned target compounds were obtained through testing a series of control factors such as adsorbent sorts, thicknesses, and superficial velocity. It was found that the efficiencies increased as the specific surface area of activated carbon and its thickness increased, and external void fraction decreased. Furthermore, mixed activated carbon with granular and constructed contents was extensively tested to reduce pressure drop through the carbon bed. It was found that the performance of higher contents of granular activated carbon was better than that of higher contents of the constructed carbon. When the mixed carbon was applied to the subway ventilation system in order to eliminate $NO_2$ and VOC simultaneously, the removal efficiencies were found to be 75% and 85%, respectively.

A Study on Developing the Evaluation Items for the Green Libraries Certification (녹색도서관 인증을 위한 평가항목 개발에 관한 연구)

  • Noh, Younghee
    • Journal of the Korean Society for information Management
    • /
    • v.32 no.3
    • /
    • pp.99-130
    • /
    • 2015
  • This study was conducted to develop and propose the evaluation indicators to evaluate the eco-friendliness of the library, when certified as the eco-friendly Green Libraries. To do this, we extracted the green library components through an analysis of the green library literatures and case studies, and surveyed the perceptions of the library staffs about the assessment factors. Finally, we developed the green library evaluation index with 11 evaluation areas, 31 evaluation items, and 135 evaluation indicators. The 11 evaluation areas are as follows; Land use and transportation, energy and environmental protection, materials and resources, water cycle management, maintenance management, ecological environment, the indoor environment, the library resources, the eco-education programs and campaigns, the staff and operations, and the computerization.

The Combined Environmental Factors on the Human Physiological and Psychological Responses in Indoor Space (실내공간의 복합 환경 조건이 인체의 생리 및 심리반응에 미치는 영향)

  • Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.3
    • /
    • pp.87-94
    • /
    • 2012
  • Kruithof demonstrated the preferred combination of illuminance levels and color temperatures. However, as Benett pointed out, difference of themal variables in such preference may be expected. The purpose of this study is to clarify the combined effects of lighting conditions(illuminance, color temperature), operative temperature on the human physiological and psychological responses. In order to observe operative temperature change in preference of color temperatures for three illumination levels, three subjects were exposed to two different conditions of color temperatures of 2,850K, 4,200K and 6,850K combined with operative temperatures(OT) of $25{\sim}31^{\circ}C$ at 100~1000lx. Thermal sensation vote and comfortable sensation vote, brightness perception vote were reported in each experiment conditions. The following results were obtained : 1) When illuminace level was at 100lx in operative temperatures of OT $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$, Color temperature affect not themal sensation but Warm-cool sensation. 2) Operative temperatures affect not brightness perception vote but visual comfort sensation vote, satisfactive sensation vote, warm-cool sensation vote and themal sensation vote.

A study on sleep environment in bedroom and segmentation of sleepers in Korea (한국인의 침실환경과 침실 사용자그룹 세분화에 관한 연구)

  • Kim, Bi-Na;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.291-296
    • /
    • 2008
  • This paper reports on the results of a questionnaire survey on actual conditions of sleep environment, sleep problems and sleep patterns in bedroom of house. The objectives of survey are: 1) classifying Korean people into several groups by sleep environment condition, sleep problem and life pattern, 2) describing the characteristics of user groups, and 3) searching needs of support for each user group. Despite of several studies about sleep condition that researched in advance, they weren't considered about user's respective characters. So it seems necessary for more studies about users' needs, and segment users to grasp their each detail needs. Therefore, this study conducted questionnaire survey gathering relevant information to classify user groups and to investigate the current bedroom condition. In the result, 702 respondents were divided into six clusters by extracted eight factors. Four clusters of them had some problems for sleep, so it could be seen that they need environmental solution for their good sleep. As the further objective, it will be connected to develop the good sleep system.

  • PDF

A Study of Thermal Comfort by Winter Temperature Humidity Change (겨울철 온도 및 습도변화에 따른 온열쾌적감에 관한 연구)

  • Kim, Se-Hwan;Lee, Sung;Kim, Dong-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.803-809
    • /
    • 2007
  • To those who spend most time within a room, comfortable indoor environment is a very critical element to job performance and health. The comfort technology, which is for enhancing comfort in human living, relates with various factors to ensure human activities efficient, comfortable, safe and satisfactory. Experiments were performed in environmental chamber. Experimental conditions were combinations from three temperatures of 18, 22 and 26C, and two relative humidity levels of 45 and 60%. Air-flow was controlled to 0.1m/s through the experiment. Four male and four female university students participated in the experiments. They had normal blood pressure and their body temperature was under $37^{\circ}C$. From the experiments for evaluating thermal sensation to the air-heating conditions, relationships among TSV, CSV, $SET^*$, PMV were analyzed. Results can be summarized as followings; Thermal neutrality $SET^*$ of man and female was $24.8^{\circ}C$. In air-heating condition, $SET^*$ values for thermal comfort zone were $23.0{\sim}26.5^{\circ}C$. These values were higher than the values from ASHRAE.