• 제목/요약/키워드: Indoor environmental factors

검색결과 292건 처리시간 0.026초

Correlation of Air Pollutants and Thermal Environment Factors in a Confined Pig House in Winter

  • Choi, Hong L.;Kim, Ki Y.;Kim, Hyunook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.574-579
    • /
    • 2005
  • Optimal management of indoor air quality in a confined pig house, especially in winter, is indispensable for preventing infectious respiratory disease to workers and animals. This study was performed to elucidate the correlation of aerial contaminants and climate factors in a confinement. It was observed that indoor air contaminants ion in the confinement was the highest at 2:00-5:00 pm in a day, followed by 8:00-11:00 pm and 8:00-11:00 am. This was attributed to the increase of pig activities in the afternoon. The concentration of total dust and total airborne bacteria was found to have a significant correlation with temperature and relative humidity (p<0.05). Correlation of total dust and total airborne bacteria, total dust and ammonia, and total dust and odor were shown statistically significant at 95% confidence level. In conclusion, temperature and total dust concentration correlated significantly with all the parameters except for hydrogen sulfide ($H_2S$). This could be explained by the fact the dryness of pig feces by increase of interior temperature and resuspension of feed deposited on the floor by the pig activity, resulted in high generation of dust which adsorbed and carried the airborne bacteria and odor compounds in a confined pig house. It was proved that the adsorptive capacity of dust with ammonia ($NH_3$) was higher than that with hydrogen sulfide ($H_2S$).

Trend Analysis of LEED Certifications: Insights and Future

  • Lee, SeungMin;Kwak, Young Hoon
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1009-1016
    • /
    • 2022
  • As environmental concerns grow, people are becoming more aware of energy efficiency, carbon reduction, and sustainable development. Leadership in Energy and Environmental Design (LEED) certification is currently the most widely recognized building environment assessment method connected to energy and the environment worldwide. This study explores trends for six factors (energy and atmosphere, materials and resources, indoor environmental quality, sustainable sites, water efficiency, and innovation in design) to assess four levels of LEED certification (Platinum, gold, silver, and certified) using 11,209 LEED projects in the United States. The study analyzes trends using scores of percentages of maximum points by certification level, ownership type, space type, and climate zones. With the interest in the Environmental, Social, and Governance (ESG) principle on the rise, this study contributes to a better understanding of the trends and future of LEED certification in the built environment sector.

  • PDF

Prediction of Indoor Radon Concentration through the Exhalation from Korean Yellow Residual Soil, Hwangtoh as a Building Material

  • LEE, Ju Yong;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권2호
    • /
    • pp.122-133
    • /
    • 2021
  • The radon gas from nature mainly considers a cause of radon problems, and it is closely affect human life cycle. Korean yellow residual soil, Hwangtoh, widely used as a building material, is considered to be one of major sources of indoor radon. However, there have, as yet, been no studies about radon from Hwangtoh in mass market brands. Here, we investigated the indoor radon concentrations and exhalation rates in four Hwangtohs from different brand names and regional features. The Closed Chamber Method (CCM) conducted by a Continuous Radon Monitor (CRM) has been used for the rates of radon exhalation. Based on equations of previous references, the indoor radon concentrations were deducted. As a result, the radon surface exhalation rates resulted in the 1.4208 to 3.0293 Bq·㎡·h-1 range. Significant differences were found among Hwangtohs according to production regions. Materials with higher radon concentration required a longer time to reach a quasi-steady state in a given environment, in other words, the number of half-life cycles increased from a set starting point. The experimentally identified Hwangtohs demonstrated its safety for construction purposes. There exists, so far, a possibility to exert influence radon emanation due to unidentified factors. Therefore, it is necessary to corroborate with more research by increasing the number of Hwangtohs, considering the other references reported high radon exhalation rates. In addition, it is highly recommended that the radon exhalation rates should be measured for all building materials for preventing human health before the material usage.

울산지역 초등학생의 알레르기비염 유병과 면역반응과의 상관성: 환자-대조군 연구 (Correlation between Allergic Rhinitis Prevalence and Immune Responses of Children in Ulsan: A Case-control Study)

  • 이지호;오인보;김아라;김민호;심창선;김양호
    • 한국환경보건학회지
    • /
    • 제41권4호
    • /
    • pp.249-258
    • /
    • 2015
  • Objectives: This study aims to investigate the correlations between the prevalence of allergic rhinitis (AR) and cytokines among elementary school children in an industrial city, Ulsan, South Korea, and to identify major environmental risk factors associated with AR prevalence. Methods: We conducted a case-control study in June 2009 and February 2010 in order to evaluate the relationship between AR and related cytokines. Data on physician-treated prevalence over the past 12 months and potential risk factors for AR were compiled through a questionnaire from a survey of 339 schoolchildren living in different urban environments. Logistic regression analysis was carried out with propensity score matched data (n=180) to assess the influences of cytokines (IL-13, IL-33, IL-4 and IL-5) on AR prevalence and to determine which environmental factors affected AR. Results: In univariate analysis, the AR prevalence was influenced by family history of AR (mother and siblings), environmental factors (odor condition and irritated symptoms of air pollution), and indoor allergens (D. farinae and D. pteronyssinus). The t-test demonstrated that eosinophils, Immunoglobulin E (IgE), and interleukins (IL-13 and IL-5) were statistically significantly different according to treatment of allergic rhinitis over the preceeding 12 months. The results of the multiple logistic regression analysis showed that a statistically significant association between several factors (such as irritated symptoms of air pollution (OR 4.075, CI 1.735-9.568), IL-13 (OR 0.825, CI 0.734-0.928), odor condition (OR 2.409, CI 0.908-6.389), and AR history of siblings (OR 2.217, CI 0.999-4.921)) and the prevalence of AR was found after adjusting for confounders. Conclusion: These results suggest that AR prevalence is significantly associated with cytokine level, genetic background, and outdoor environmental factors. Although living in a polluted area and genetic background can contribute to an increased risk of childhood AR, cytokine level should be considered as an important factor in the treatment of AR in the last 12 months.

실내 클라이밍 짐 홀드의 관리방법에 따른 미생물 오염에 관한 연구 (A Study on Microbial Contamination according to Effective Management Strategies of Indoor Climbing Gym Holds)

  • 김지인;신혜진;정유정;서해송;오기택;박용후;김성균
    • 한국환경보건학회지
    • /
    • 제50권2호
    • /
    • pp.102-112
    • /
    • 2024
  • Background: Despite the rise in the number of domestic indoor climbing gyms, there is a lack of specific hygiene standards and research on the holds installed in them. Holds can act as vectors for microbial transmission through the hands, posing a risk of infectious diseases, especially with damaged skin. Objectives: The aim of this study is to investigate the contamination level and species of microorganisms on holds according to the management methods practiced in indoor climbing gyms and identify effective strategies for reducing microbial contamination. Methods: We investigated factors that may influence microbial contamination of holds, including hold management methods, user information, and hygiene management at three climbing gyms in Seoul. A total of 72 holds were sampled, 18 for each management method of brushing, high-pressure washing, and ethanol disinfection. Samples were cultured on LB and blood agar at 37℃ for 48 hours to calculate CFUs. PCR assay targeting 16S rRNA was carried out to identify microorganisms. Dunn-Bonferroni was employed to see the microbial reduction effect of the management method and the difference in microbial contamination by management method and climbing gym. Results: As a result of microbial identification, microorganisms such as Bacillus, Staphylococcus, and Micrococcus, which were derived from various environments such as skin and soil, were discovered on the surface of the climbing hold. Among the discovered microorganisms, some species had potential pathogenic properties that could cause food poisoning, gastrointestinal disease, bacteremia, and sepsis. All hold management methods were effective in reducing microorganisms (p<0.05), with ethanol disinfection being the most effective (p<0.001). Conclusions: Our results indicate that there are potential pathogens on holds that demand thorough management for microbial prevention. Proposed methods include regular brushing and ethanol disinfection in addition to high-pressure washing with long cycles, which are the existing forms of hold management. Further studies on shoe management are advised to curb soil-derived microorganisms.

서울시 환경보건정책 로드맵 수립 (Process and Results of Seoul Metropolitan Government's Environmental Health Policy Road Map)

  • 임지애;권호장;김신범;최영은;구슬기;정회성;김명한;최경호
    • 한국환경보건학회지
    • /
    • 제40권5호
    • /
    • pp.425-434
    • /
    • 2014
  • Objectives: The purpose of this study is to introduce the establishment process and results of the Seoul Metropolitan Government's road map on environmental health policy. Methods: The process consisted of expert group meetings, civic participation, research, and questionnaire survey for priority environmental health policy agenda items in Seoul. Results: The announced vision for the environmental health policy was "a healthy environment, safety in Seoul". This policy was established in order to define environment health policy initiatives for a period of five years with an aim to protect Seoul citizens' health from hazardous environmental factors. The resulting Seoul environmental health policy consisted of four areas and 16 key agenda items. The four areas were "Protection for children against hazardous materials", "Enhancement of health and safety of all", "Carcinogen-free and endocrine-disrupting chemical-free Seoul (reducing environmental exposure to hazardous materials), and "Establish the foundation of environmental health policy". Sixteen key agenda items include the enhancement of management of spaces for children, certification of environmental health status at schools, establishment of a unit responsible for the environmental health of children, strengthening environmental health management for susceptible populations (children, the aged, and the socioeconomically vulnerable), management of hazardous materials, physical hazardous factors (noise, radiation, etc.), indoor air quality, and the enhancement of monitoring, research, and regulation of environment health. Conclusion: The Seoul Metropolitan Government established an environmental health policy road map for a five-year period (2013-2017). To implement this environmental health policy, budget allocation, and detailed execution plans are required.

표준실내기후 설정에 관한 기초조사연구 -열환경요소와 착의량이 온냉감반응에 미치는 영향- (A Field Survey on the Standard Establishment of Thermal Indoor Climate - with the effect of thermal environmental factors, and clothing to the thermal sensation -)

  • 최혜선
    • 대한설비공학회지:설비저널
    • /
    • 제16권6호
    • /
    • pp.590-605
    • /
    • 1987
  • The purpose of this study was to investigate thermal environmental factors, thermal clothing properties, and thermal sensation of the office workers in four selected office buildings in Seoul, and to determine the effect of thermal environmental factors and clothing insulation to the thermal sensation of the subjects. The subjects selected from each office were 5 males and 5 females at a time. Thermal environmental factors(DBT, GT, RH, MRT, $ET^{\ast}$) and clothing variables such as clothing weight per body surface $area(g/m^2)$ and estimated clothing insulation values(clo) were significantly different among each seasons(p<0,001). Means of $ET^{\ast}$ and estimated clothing insulation values of each season were as follows; Winter; $20.84^{\circ}C$ $ET^{\ast}$ with 0.72 clo for male and 0.79 clo for female Spring and fall; $23.65^{\circ}C$ $ET^{\ast}$ with 0.59 clo for male and 0.68 clo for female Summer; $26.00^{\circ}C$ $ET^{\ast}$ with 0.47 clo for male and 0.53 clo for female. In comparison these data with ASHRAE Standard, the subjects were predicted to feel comfort-able in spring and fall, and slightly hot in summer and slightly cold in winter because of high and low clo respectively. But the result of this survey showed more than $80\%$ of the occupants were thermally comfortable at a given environmental temperature and clo.

  • PDF

시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정 (Estimation of Ventilation Rates in Korean Homes Using Time-activity Patterns and Carbon Dioxide (CO2) Concentration)

  • 박진현;류현수;허정;조만수;양원호
    • 한국환경보건학회지
    • /
    • 제45권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide ($CO_2$) and $CO_2$ generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of $CO_2$ generation by breathing to estimate the indoor $CO_2$ generation rate. To estimate the ventilation rate, several factors such as the $CO_2$ generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor $CO_2$ concentrations measured by sensors, and outdoor $CO_2$ concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The $CO_2$ generation rate from breathing was $13.9{\pm}5.3L/h$ during sleep and $15.1{\pm}5.7L/h$ in a sedentary state. Indoor and outdoor $CO_2$ concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were $42.1m^3/h$ and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.

박물관 환경 분석을 통한 동산문화재 영향인자에 대한 연구 (Study on Environmental Factors for Movable Cultural Properties in Museum)

  • 김일규;서용수;이주현
    • 대한환경공학회지
    • /
    • 제31권9호
    • /
    • pp.811-816
    • /
    • 2009
  • 최근 문화재의 훼손을 미연에 방지하기 위하여 보존환경 및 훼손영향에 대한 연구가 중요하게 대두되고 있다. 본 연구에서는 국내 박물관 3곳의 환경 중 동산문화재의 보존환경과 관련된 전시실, 전시케이스, 수장고에서 온 습도, 산류, 암모니아, 환원황화합물, 알데히드류를 조사하여 주요 영향 인자를 확인하고자 하였다. 조사 결과 온 습도, 총휘발성유기화합물, 아세트 알데히드는 빈번히 국 내외의 박물관 보존환경 기준 및 실내공기질 기준을 초과하였고, 포름알데히드, 염소, 암모니아는 간헐적으로 기준을 초과하는 특성을 보였다. 빈번히 기준을 초과한 온도, 습도, 총휘발성유기화합물, 아세트알데히드, 동산문화재의 주요 영향인자로써 동산문화재의 효과적인 보존 및 관리를 위해서 이들 인자는 적절한 제어가 필요함을 확인하였다.