• Title/Summary/Keyword: Indoor environment performance

Search Result 590, Processing Time 0.032 seconds

Planning of Apartment Units for Improving Natural Ventilation Performance based on the Analysis of Indoor Pollutant Concentrations (오염농도 분포 해석을 통한 공동주택의 자연환기성능 향상을 위한 평면계획)

  • Kim, Jiyoeng;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.41-48
    • /
    • 2005
  • Before occupation of an apartment housing, the builders are required to inform the test result of IAQ to the public. However, there is no simplified method to predict IAQ before measurement of pollutant concentration. In this study, a simplified way of predicting IAQ based on the distribution of indoor pollutant concentration is proposed. 7 different cases of air change rate have been simulated through CFD analysis to get the distribution ratio of each pollutant material and then simplified functions were used with CRIAQ1 values derived from CFD simulation to evaluate by comparing the influence of each material in the indoor pollutant concentration. Again, a lot of efforts which can improve the indoor air quality have been performed. Materials used in indoor space are labeled with their pollutant emission level. Installation of ventilation system in residential buildings will be regulated by a building codes sooner or later. But it is important to understand the fact that layout of walls, location or size of openings will influence the indoor air flow and pollutant concentration. And location of emitting material influences to indoor air pollutants distribution. But until now there is few recognition and consideration of these factors. Therefore, in this paper the effects of these factors is proved and some kind of guideline is made for designers after a comparison of typical apartment floor plan and a new type plan with their average pollutant concentration and its distribution of each room. CFD(Computational Fluid Dynamics) program was used to show the indoor air flow and pollutant concentration distribution. For this purpose, a typical $100m^2$ apartment floor plan was chosen as a case study model and several alternatives were reviewed to improve the IAQ performance. The simulation took place in the condition of natural ventilation through windows.

Study on the Performance of Wireless Local Area Network in a Multistory Environment with 8-PSK TCM

  • Suwattana, Danai;Santiyanon, Jakkapol;Laopetcharat, Thawan;Charoenwattanaporn, Monton;Goenchanart, Ut;Malisuwan, Settapong
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.549-551
    • /
    • 2002
  • A Wireless Local Area Network (WLAN) is a flexible data communication system implemented as an extension to, or as an alternative for, a wired LAN with in a building or campus. However, communications in an indoor environment present problems not encountered in outdoor wireless communication systems. Since cellular type systems are interference limited, the indoor environment is more hostile than the outdoor environment due to the lower propagation constant. In this paper, the equation for the signal to interference ratio in a multistory building will be derived. Knowing the S/I ratio, the floor frequency reuse can be determined. Finally, the simulation in this research is designed to study the performance (BER) of WLAN system in the multistory environment by applying the 8-PSK Trellis Coded modulation technique. The procedure allows a quick evaluation of BER in Wireless LAN system due to the co-channel interference.

  • PDF

Evaluation of the Indoor Thermal Comfort in Naturally Ventilated Apartment During Summer (자연환기가 가능한 서울시 공동주택의 하절기 실내 온열 쾌적성 평가)

  • Lee, Seung-Jae;Cheong, Chang Heon;Hwang, Suckho;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.59-66
    • /
    • 2010
  • Natural ventilation is major strategy of 'sustainable building'. It aims to supply fresh air to the indoor, and to remove heat from the indoor during summer. In the latter point of view, natural ventilation can be grouped into two main strategies, daytime ventilation and night cooing. If we take advantage of these two natural ventilation strategies, indoor thermal comfort can be significantly improved. This study focused on grasping the current situation and problem of indoor thermal comfort of the naturally ventilated residential buildings to seek for direction of later studies. Additionally, thermal comfort of residence where the interior blind and exterior insulation were applied was analyzed. It was analyzed that the percentage of the time which satisfy the indoor acceptable operative temperature during summer was 90 ~ 95% and the heat control performance of natural ventilation has a limitation. When the interior blind and exterior insulation were applied, indoor thermal comfort was significantly improved. However, it still need more improvement.

Indoor Environment Comfort Evaluation of Public Library Evaluation (공공도서관 열람실의 실내환경 쾌적성 평가)

  • Lee, Ji-Hoon;Seo, Min-Seok;Yun, Jun-Hee;Cha, Jung-Hoon;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.4
    • /
    • pp.317-322
    • /
    • 2011
  • Recently, our society is becoming increasingly enthusiastic to acquire knowledge and quality education. Thus, private houses, schools, public libraries and even subways are becoming places to acquire knowledge. Out of all these places, the library, where people visit most frequently to study, has to be quiet, effective and pleasant in order to provide the most efficient place for maximizing learning performance. Many people use public libraries and the age group of people who visit public libraries are very diverse, which makes it particularly necessary to provide the conditions mentioned above. The purpose of this paper is to measure and analyze the differences of thermal comfort and soundscape of library N, which is located in the quiet woods, and library G, which is located in the city center. The measurement and analysis results will be used to evaluate which library has a more pleasant environment.

  • PDF

Performance Analysis of LoRa(Long Range) according to the Distances in Indoor and Outdoor Spaces (실내·외 공간에서 거리에 따른 LoRa(Long Range) 성능 분석)

  • Lim, Junyeong;Lee, Jaemin;Kim, Donghyun;Kim, Jongdeok
    • Journal of KIISE
    • /
    • v.44 no.7
    • /
    • pp.733-741
    • /
    • 2017
  • LPWAN(Low Power Wide Area Network) technology is M2M (Machine to Machine) networking technology for the Internet of Things. The technology is designed to support low-power, long-distance and low-speed communications that are typical of LoRaWAN(Long Range Wide Area Network). To exchange inter-object information using a LoRaWAN, the link performances for various environments must be known. however, active performance analysis research that is based on an empirical environment is nonexistent. Therefore, this paper empirically evaluates the performance of the LoRa (Long Range) link, a physical communication technology of the LoRaWAN for various variables that may affect the link quality in indoor and outdoor environments. To achieve this, a physical performance monitoring system was designed and implemented. A communication experiment environment was subsequently constructed based on the indoor and outdoor conditions. The SNR(Signal to Noise Ratio), RSSI(Received Signal Strength Indication), and the PDR(Packet Delivery Ratio) were evaluated.

Strategy of Energy Saving and Thermal Environment Improvement for Intermittent Heating System in Apartment Buildings (공동주택 간헐난방시스템의 에너지 절감 및 열환경 개선방안 연구)

  • Ahn Byung-Cheon;Lee Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.88-93
    • /
    • 2005
  • In this study, the operational characteristics on heating performance and energy consumption for intermittent hot water heating system in apartment buildings were research by simulation. The effects of apartment inlet hot water temperature and operation time per day on energy consumption and indoor thermal environment are investigated. The strategy of energy saving and thermal environment improvement is suggested in comparison with the existing ones.

Investigation of the sound insulation performance of balcony window through field measurement (현장측정을 통한 발코니 창호의 차음성능에 관한 연구)

  • Ju, Mun Ki
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.63-68
    • /
    • 2009
  • As with the disappearance of a living room window due to the trend in apartment housing construction that prefers a larger, expanded living room, the sound insulation performance of the balcony window is becoming an important factor to determine the level of indoor noise at an apartment unit. Considering that the indoor noise inside an apartment unit is mandated by law at or below 45dB(A), the balcony window is increasingly assuming an even more important role. Sound insulation performance of the window was measured by examining differences in data involving varying angles of incidence of the sound source as obtained from the same balcony window. Also, acoustic intensity measuring was performed at and around the window to determine its sound insulation quality. Results of measuring on the sound source's angles of incidence indicated that the performance showed some differences in lower frequency ranges, though with no significance. Intensity measuring results showed that the sound insulation performance was reduced near the connection part of the window and the window frame.

Effects of Housing Systems on Behaviour, Performance and Welfare of Fast-growing Broilers

  • Zhao, Zi-Guang;Li, Jian-Hong;Li, Xiang;Bao, Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.1
    • /
    • pp.140-146
    • /
    • 2014
  • This experiment aimed to evaluate the effects of different housing systems on behavioral activities, welfare and meat quality of fast-growing broilers. Two hundred broilers were allocated into two housing systems: indoor housing vs indoor with outdoor access. Their general behavior (feeding, drinking, fighting, standing, lying, walking, investigating, dust-bathing and preening) was observed, and tonic immobility, fluctuating asymmetry of legs and wings were measured, and meat quality was analyzed. The results showed that the indoor-housed broilers with outdoor access had significant higher standing, walking, investigating, dust-bathing and preening than those indoor only. However, farming system was not found to significantly affect their feeding, drinking and fighting activities (p>0.05). The value of FA of tibia length of the broilers with outdoor access was significantly lower than that of the indoor-housed birds ($1.57{\pm}1.30$ vs $2.76{\pm}1.40$, p<0.05), while no difference was found for the value of FA in tibia diameter and wing length (p>0.05). TI of the broilers with outdoor access was 165.5 that was significantly higher than that (147.2) of the indoor birds (p<0.05). However, death rate in the outdoor run groups was significantly higher than that of the indoor ones ($2.0{\pm}0.81$ vs $4.0{\pm}0.82$, p<0.05). Meat quality was not affected by the two farming systems. It can be concluded that the results of this study may suggest that the indoor housing with outdoor access provides enriched environment for broilers and facilitates the expression of natural behaviors of the broilers but resulted in poorer performance and higher death rate.

Verification of the Validity of Moisture Transfer Model for Prediction of Indoor Moisture Generation Rate (실내 수증기 발생량 예측을 위한 습기 전달 모델의 검증에 관한 연구)

  • Lee, Dong-Kweon;Kim, Eui-Jong;Choi, Won-Ki;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • Moisture in a building is one of the most important variables influencing building performance, human health, and comfort of indoor environment. However, there are still lacks in the knowledge of understanding the moisture problem well and controlling moisture. Accordingly, in order to provide the fundamental data to control moisture contents in the indoor air, this study was to predict moisture contents transferred through building envelopes and indoor moisture generation rate. Moisture transfer model was made by physical relations in each node, and the indoor moisture generation rate was gained by comparing the model with experimental analyses. From the study, we found out that moisture generation rate was critical and day-periodic, so that we predicted the indoor moisture content by substituting the constant value gained from the average in a day for the moisture generation rate.

Development of Integrated Control Methods for the Heating Device and Surface Openings based on the Performance Tests of the Rule-Based and Artificial-Neural-Network-Based Control Logics (난방시스템 및 개구부의 통합제어를 위한 규칙기반제어법 및 인공신경망기반제어법의 성능비교)

  • Moon, Jin Woo
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.97-103
    • /
    • 2014
  • This study aimed at developing integrated logic for controlling heating device and openings of the double skin facade buildings. Two major logics were developed-rule-based control logic and artificial neural network based control logic. The rule based logic represented the widely applied conventional method while the artificial neural network based logic meant the optimal method. Applying the optimal method, the predictive and adaptive controls were feasible for supplying the advanced thermal indoor environment. Comparative performance tests were conducted using the numerical computer simulation tools such as MATLAB (Matrix Laboratory) and TRNSYS (Transient Systems Simulation). Analysis on the test results in the test module revealed that the artificial neural network-based control logics provided more comfortable and stable temperature conditions based on the optimal control of the heating device and opening conditions of the double skin facades. However, the amount of heat supply to the indoor space by the optimal method was increased for the better thermal conditioning. The number of on/off moments of the heating device, on the other hand, was significantly reduced. Therefore, the optimal logic is expected to beneficial to create more comfortable thermal environment and to potentially prevent system degradation.