• Title/Summary/Keyword: Indoor dusts

Search Result 23, Processing Time 0.027 seconds

Heavy Metal Contamination of Indoor, Outdoor and Playground in Middle and High School in the Jeonju-City, Korea (전주시내 중고등학교 실내.외 환경의 중금속 오염에 대한 연구)

  • 조규성
    • Journal of Environmental Science International
    • /
    • v.9 no.6
    • /
    • pp.495-503
    • /
    • 2000
  • Dust samples were collected from 17 middle and high schools in the Jeonju-city. heavy metal concentrations were determined for the dry-deposited dusts from indoor and outdoor of classroom and playground of each sampling site. Concentrations of Cd, Cr, Cu, Ni, Pb and Zn in indoor\`s dusts were highly concentrated. Also heavy metal concentrations in outdoor\`s dusts were similar to that of indoor\`s dusts. Concentrations of Cd, Cu, and Zn in the dusts were much higher than the world average contents in soil and environmental orientation value. These levels are similar to those of the dust samples at middle schools located at Kangseo-gu and Yangchon-gu , Seoul. Playground dusts in 6 schools exhibited the enhanced heavy metal pollution with a pollution index (by Kloke) greater than 1.0. Most indoor and outdoor dusts exhibited the enhanced heavy metal pollution with a pollution index(by Cullbard et al.) greater than 1.0.

  • PDF

A Study on the Electrostatic Precipitation as a Function of Resistivity using various Indoor Dusts (실내 분진의 비저항 특성에 따른 전기집진 효율에 대한 연구)

  • Cheong, Seong-Ir;Choi, Young-Min;Ahn, Young-Chull;Lee, Jea-Keun;Kangk, Eun-Chull;Lee, Euy-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.448-453
    • /
    • 2006
  • Electrical resistivity is an important property for the collection efficiency in the electrostatic precipitator. In this paper, electrical resistivities of tobacco dusts, yellow sand dusts and pine pollens are measured using a high voltage conductivity cell based on JIS B 9915. The resistivities of three kinds of indoor dusts are about $1{\times}10^7\;{\Omega}{\cdot}cm^2$ in the normal range and dust collection efficiency using an electrostatic precipitator at to face velocity of 1.0 m/s shows over 99% for the three kinds of indoor dusts.

  • PDF

Effect of indoor environmental factors on the physical symptoms of dental hygienists (실내 환경 요인이 치과위생사의 신체증상에 미치는 영향)

  • Hong, Min-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.2
    • /
    • pp.197-204
    • /
    • 2014
  • Objectives : The purpose of the study is to examine the effect of the indoor environmental factors of dental hygienists on physical symptoms. Methods : The subjects were 210 dental hygienists in dental hospitals and clinics in Seoul, Gyeonggi Province, Incheon and South Chungnam Province from May 1 to June 20, 2013. Results : There were significant differences between the presence or absence of windows in respiratory symptoms and eye symptoms. Room temperature, bad smell, and dry humidity had significant influences on physical and respiratory symptoms. Dermatological and ophthalmological symptoms were affected by dryness, smell and dusts. Dusts and bad smell also had influences on a variety of subjective symptoms. Conclusions : The indoor environments of dental hospitals and clinics affect the respiratory, dermatological, and ophthalmological symptoms because various hazardous materials are generated by the dental treatment. Therefore dental hygienists should have a correct understanding of bacteria, dusts and bio-aerosol in order to ensure the successful environmental control.

Air Contamination in an Underground Commercial Floor assayed by GAseous Pollutants, Dusts and Mutagenicity (빌딩 地下商街의 空氣性狀 및 분자의 變異原性)

  • 兪榮植
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.46-52
    • /
    • 1987
  • There are many factors such as airtighteness and high density of merchandises or passengers that contaminate indoor air in underground commercial floor. So it is very important to know air quality and quantity of contamination in underground market increasing in number lately. It was from these viewpoints that gaseous pollutants, dusts and mutagenicity of organic compounds extracted from dusts in an underground market were investigatd. Organic ompounds (tar) were extracted by Soxhlet extractor with benzene as a solvent. Mutagenicities of these extracts were evaluated by the preincubation method using Salmonella typhimurium TA 100 and TA 98 strains with and without S9mix. The results obtained were as follows: It seemed to be under the influence of outdoor air that the concentrations of $CO, CO_2, NO, NO_2$ and dusts were higher in winter than summer. The concentration of $CO_2$ was higher in indoor than outdoor, but the concentration of NOx was similar in both sampling areas. Metal contents in dusts attached to the ventilation ducts were as follows showing in order of high concentration : Fe (9000-22000ppm), Zn(1200-2300ppm) and Pb (280-590ppm). The contents of tar were 6-33% of dusts, and higher than those from dusts collected by high volume air sampler. The extracts from dusts attached to the inlet duct exhibited lower mutagenicity than those from dusts attached to the outlet duct. This finding seemed to suggest that mutagenic substances were in creasing in underground. There was no seasonal difference of mutagenicity toward TA 98. Toward TA 100 in the presence of S9mix, the mutagenicity was about 3 fold higher in winter than summer. The mutagenicities of tar extracted from dusts collected by high volume air sampler were different from those attached to the ventilation ducts. The former showed 2-3 fold higher mutagenicity than the latter toward TA 100. However no difference showed between the former and the latter toward TA 98 in the absence of S9mix, but the former was 4-5 fold higher than the latter in the presence of S9mix.

  • PDF

Contamination Characteristics of Heavy Metals in Indoor, Outdoor and Playground of Schools in the Gochang-Gun, Chonbuk Province of South Korea (전북 고창지역 학교 실내외 환경의 중금속 오염 특성)

  • Kim, Yong-Hwan;Chung, Duk-Ho;Cho, Kyu-Seong
    • Journal of the Korean earth science society
    • /
    • v.27 no.1
    • /
    • pp.73-82
    • /
    • 2006
  • Dust samples were collected from 10 middle and high schools in the Gochang-Gun, Korea. Heavy metal concentrations were determined for the dry-deposited dusts from indoor and outdoor of classroom and playground of each sampling site. Concentrations of Cd, Cu, Pb and Zn in indoor's dusts were highly concentrated. Also concentrations of Cu, Ni, Pb and Zn in outdoor's dusts were highly concentrated. Concentrations of Cd, Cu and Zn in the dusts were much higher than the world average contents in soil and environmental orientation value. These levels are similar to those of the dust samples at middle schools and high schools located in Jeonju-city, Korea. Compared with concentrations of heavy metals in soils and dusts in Korea, the environment of indoor and outdoor of classroom is highly concentrated except for Cu, Zn. The concentrations of playground is less than that of residential dust and main road dust and playground in Jeonju-city. Playground dusts in 1 school exhibited the enhanced heavy metal pollution with a pollution index (Kloke, 1979) greater than 1.0, but indoor and outdoor dusts in 7 schools exhibited the enhanced heavy metal pollution with a pollution index (by Kloke) yester than 1.0.

Characteristic Assessment of Heavy Metals in Dusts Collected by the Air Filtration System at Subway Stations in Daegu, Korea (대구지역 지하철역사 공기여과필터 포집먼지에 함유된 중금속성분의 특성평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Shin, Dong-Chan;Kwak, Jin-Hee;Lee, Myoung-Sook;Yoon, Ho-Suk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Samples of subway dust were collected by the air filter system of 30 subway stations on Daegu subway line 1 in January 2008. Samples were sieved below 100 ${\mu}m$, and 14 elements were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic sources were significantly affected by indoor dusts than outdoor dusts. Results of pollution indices of heavy metals indicated that indoor dusts were more contaminated with heavy metal ions than outdoor dusts. The correlation analysis among trace elements indicated that components were much correlated in the order of natural sources-anthropogenic sources, anthropogenic sources-anthropogenic sources, natural sources-natural sources in both indoor and outdoor dusts. Trace element components of outdoor dusts were largely correlated than those of indoor dusts. In addition, indoor dusts were significantly affected by outdoor dusts rather than depth from the surface or the average daily number of subway passengers.

Characteristics of the Air-side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners (공기조화기용 열교환기의 공기측 파울링 입자 분석 연구)

  • 안영철;신희수;황유진;이창건;이재근;이현욱;안승표;윤덕현;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.611-617
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the characteristics of the air-side particulate fouling materials in finned-tube heat exchangers of air conditioners. Air conditioners being used in the field such as inns, restaurants, and offices are collected in chronological order in use. Typical fouling materials on the heat exchangers include fibers and dusts ranged from 6.6 to 20.9 ${\mu}{\textrm}{m}$ in mass median diameter.

Student Exposure to Airborne Dusts in Classroom of Middle Schools (중학교 학생들의 분진폭로에 관한 조사연구)

  • 이영길;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.2
    • /
    • pp.25-33
    • /
    • 1987
  • This study was carried out to evaluate student exposures to dust in classroom of middle schools. A total of four schools, such as two in an urban and two in a rural area, were selected for this study. In this study, airborne dust concentrations were measured during a period from July 8 to July 18, 1986. Additional measurements of dust concentrations were conducted from November 4 to 7, 1986 to compare the results by seasonal variation. The results of this study were as follows. 1. Respirable dust concentrations were measured by both filtration method (C mg/m$^3$) and Digital Aerosol Monitor (cpm) to calculate anexchange factor K. K- value was 0.159 as follows. $K=\frac{c}{cpm} = \frac{2.71}{17.09} = 0.159$ 2. In summer when windows were opened, the concentrations of airborne respirable dusts measured by filter sampling method were 0.54-1.37 mg/m$^3$ in the morning and 0.79-1.75 mg/m$^3$ in the afternoon. Thus, higher levels were indicated in the afternoon. Meanwhile, the concentrations of airborne respirable dusts measured in winter were approximately twice as high as those in summer. 3. The highest dust concentrations were determined in School D which is a coeducational school with classroom of concrete floor. Walking roads in School D were not paved and students did not wear indoor-shoes. Dust levels in School D were approximately twice as high as levels in School B. All of the measured dust levels in four schools exceeded Korean Standard for outdoor air, 0.3 mg/m$^3$ for 24 hours. Results by Digital Aerosol Monitor indicated that there was no significant difference in dust levels among grades. The concentration of airborne dusts in the classroom was 1.5-3.0 times higher than that in the hall way. The concentration of airborne dusts during recess was 1.3-1.6 times higher than that during class. In winter, the dust concentrations during clean-up exceeded the permissible exposure limit, 10 mg/m$^3$ (as total dusts), for occupational exposures. 4. The concentrations of total dusts measured in winter were 1.5-2.4 times higher than those of respirable dusts measured simultaneously.

  • PDF

Properties of Fine Dust Adsorption Matrix Based Blast Furnace Slag using Bentonite (벤토나이트를 활용한 고로슬래그 기반 미세먼지 흡착형 경화체의 특성)

  • Kim, Yeon-Ho;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.40-41
    • /
    • 2019
  • Fine dust, which is emerging as a global problem, attracted much attention recently in Korea. One of the reasons is that recent factory relocation and expansion in China affected the increase of domestic fine dust concentration due to the influence of the Yangtze river battalion and westerlies. Fine dust is a big problem not only in outdoor but also indoors. The room requires periodic ventilation and is also essential for improving indoor air quality. The fine dusts are designated as Group 1 carcinogens in WHO and the risk of fine dusts on the human body due to respiratory diseases is also increasing. In this study, the characteristics of the fine dust adsorption matrix are examined and the actual application direction is derived.

  • PDF

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF