• Title/Summary/Keyword: Indoor dust

Search Result 240, Processing Time 0.028 seconds

A Study on the Oil-mist/Smoke Collecting Module for the Pure Energy Recycling (청정에너지 회수용 유증기/매연 포집모듈에 관한 연구)

  • Kim, Myung-Soo;Ohkura, Shigenobu;Ham, Koung-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.279-284
    • /
    • 2009
  • Traditionally, so-called "industrial waste gases", such ad exhaust from boilers at industrial installations and a large quantity of soot discharged from power station, before their release into the atmosphere, have been on occasion subjected to an air cleaning process to remove fine particles that may pollute the atmosphere (such as mist and dust containing various powdery or oily substances and moisture from industrial waste gases). The release of industrial waste gases containing these particles directly into the atmosphere poses a serious threat to the earth environment; and recovery of these noxious substances is required by law in some countries and local governments. in urban areas, air pollution from automobile exhaust and others creates a serious condition. Some homes are equipped with and use indoor air purifiers. In many of the kitchens of restaurants, smoke generated during cooking and otherwise contaminated air are cleansed by air purifiers before being released outside or recycled inside. For the dust collecting devices to recover the fine particles contained in contaminated air, the cause for air pollution and how to purify air, many types based on various principles are known. Specifically, classified based on theories of particle collection, filtration, gravity, inertia, centrifugation, electricity, and cleaning types are cited as available processes. Among them, an appropriate type is selected according to the size or type of fine particles to be collected and conditions for installation. For the efficiency of dust collection, a filtration system (by using bag filters and others) and electric system are particularly outstanding and are therefore used widely in various areas of industry. In this research, rotary type high performance oil mist and smoke collecting system with self auto cleaning device equipped with the cleaning fluid spraying section is investigated.

  • PDF

Lung Function of Grain Millers Exposed to Grain Dust and Diesel Exhaust in Two Food Markets in Ibadan Metropolis, Nigeria

  • Iyogun, Kemi;Lateef, Suraju A.;Ana, Godson R.E.E.
    • Safety and Health at Work
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2019
  • Background: Despite growing concern over occupational exposure to particulate matter (PM) such as grain dust and diesel exhaust, information about the exposure level and health implications among workers in small-scale milling enterprises in developing countries like Nigeria has not been adequately documented. The purpose of this study was to assess the level of exposure to grain dust and diesel exhaust and effect on lung function among grain millers in food markets in Ibadan metropolis, Nigeria. Methods: The study adopted descriptive cross-sectional design with a comparative approach. Sixteen grain milling shops each were randomly selected from two major food markets in Ibadan metropolis for indoor $PM_{10}$ and $PM_{2.5}$ monitoring. Seventy-two respondents each were proportionately selected from grain millers and shop owners for forced expiratory volume in one second and peak expiratory flow rate tests. Results: The $PM_{2.5}$ concentrations for both market locations ranged between 1,269.3 and $651.7{\mu}g/m^3$, while $PM_{10}$ concentrations were between 1,048.2 and $818.1{\mu}g/m^3$. The recorded concentrations exceeded the World Health Organization guideline limit of $50{\mu}g/m^3$ and $25{\mu}g/m^3$ for $PM_{2.5}$ and $PM_{10}$, respectively. As compared with control group (2.1 L), significantly lower forced expiratory volume in one second value (1.61 L) was observed among the exposed group (p < 0.05). Likewise, significantly lower peak expiratory flow rate value (186.7 L/min) was recorded among the exposed group than the control group (269.51 L/min) (p < 0.05). Conclusion: Exposure to grain dust and diesel exhaust accentuated respiratory disorders with declines in lung functions amongst grain millers. Improved milling practices and engaging cleaner milling facilities should be adopted to minimize exposure and related hazards.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

Indoor Environment Control System Utilizing The Internet of Things (사물인터넷을 활용한 실내 환경 제어 시스템)

  • An, Yoon-Jung;Kim, Dong-Hyeok;Lee, Jee-Hyun;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.645-650
    • /
    • 2017
  • It is a system that controls temperature, humidity and fine-dust to make interior environment more comfortable for modern people who spend 90% of the time in indoor. In an experiment of finding which one of temperature and humidity influence more to discomfort index, for a fixed temperature of 21, discomfort index increased by 0.1 with a 1 change of humidity, and for a fixed humidity of 40, discomfort index increased by 1.2 with a 1 change of temperature. As a result, it was found that the temperature is more influential than the humidity to discomfort index. In an experiment of measuring communicational limitation of Bluetooth, the communication was possible for at most 30 meters without obstacles. With high obstacles like walls or steel bars, it was able to penetrate at most 2 obstacles and maximum distance which it can communicate was 10 meters for just one high molecule obstacle.

The Study on Natural Ventilation in Working Places with the Noxious Gas and Dust (유해가스 및 분진이 발생하는 작업장내의 자연환기에 대한 연구)

  • Chu, Byung-Gil;Kim, Chul;Choi, Jong-ook;Yoo, Soo-Yul
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.72-79
    • /
    • 2000
  • In recent, occupational diseases in harmful working places become a social issue. It is the well-known fact that a respiration in polluted working places exert a serious effect on health of workers. Accordingly, the cutting off contaminants air originally is the best way to improve working environments. In these cases, ventilation systems should be essentially installed to dilute or exhaust the contaminated indoor air. In this study, we investigated the characteristics of ventilation system of the noxious gas in working indoor places with natural ventilation by using COMET. The numerical simulations were carried out the natural ventilation with two phase(air, dust). For turbulent flow, Reynolds stresses were closed by the standard $\kappa$-$\varepsilon$ model. The results are as follows ; 1) In the natural exhaust in the working place, the flows of the central region have a more rapid velocity vector than the right and left one. 2) Numerical results show that the distribution of contaminants concentration have greater influence on convection than the case of diffusion by government of velocity vectors. 3) To observe the velocity variation with distance, three location of distance are considered. As results, it shows that the velocity are 0.075(m/s) at y=5(m), 10(m) and mean concentration are raised 10.6% at y=5(m), 10(m). 4) We have presented the useful data for the adequate counterplan in the harmful working places by carrying out the various investigation of the natural ventilation.

  • PDF

A Study for Development the Air Cleaner Using Air Ionizing Phenomena and Optical Catalizer (공기전리 현상과 광촉매를 이용한 공기정화 장치 개발에 관한 연구)

  • Shim, Chung-Han;Lee, Won-Dae;Lee, Dong-Hoon;Jung, Yong-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.28-33
    • /
    • 2006
  • The rapidly advanced industrial society takes advantage of high-technology, but it also suffered from the side effects such as various diseases by contamination. Of these problems, air pollution is considered as the most important problem nowadays. Air contamination is not only limited outdoors, but it also causes more serious effect in our indoor air environment. Depending on the notion that indoor air effects physical health seriously, the needs of the air cleaner is more earnest. Therefore, the main purpose of this study is to develop the air cleaner to meet the standard and get rid of poisonous and harmful material from the atmosphere by using a Corona Discharge. According to the purpose of this study, We set the negative ion generator, the UV, $TiO_{2}$ optical catalyzer, the electrical dust collector and the air filter in series order. It emits a lot of negative ions. We use these ions to purify harmful factors and contaminated materials. We collect the dust using static power that comes from the discharge of corona. At the same time, we try to develop the air cleaner to keep the air quality to meet the standard and kill the various viruses using UV LED and $TiO_{2}$ optical catalyzer. In this study, we use the UV LED that is smaller and efficient than a existing UV lamp. What is more, the UV LED has a features that a stabilizer occupying much space is not needed any more.

Effect of environmental relationship between fungal exposure and asthma in children (천식질환이 있는 영유아가 환경요인 중 곰팡이 노출에 따른 영향)

  • Choi, KilYong;Kim, ChaeBong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.409-410
    • /
    • 2018
  • Background: Asthma is one of the most common chronic diseases and can be affected by environmental factors. It has been reported that exposure to indoor environmental factors can cause infantile asthma during infancy and childhood, but the previous studies are not yet clear. Climate change has recently been shown to increase indoor mold. Exposure to fungi is known to be directly related to the development of aggravation. Methods: This study was conducted from July 20, 2016 to September 30, 2016. The study was conducted on 90 household with children under the age of 7 who attend atopy school. The questionnaire surveyed allergic symptoms, social and demographic characteristics, and environmental characteristics. Environmentally hazardous substances were measured such as temperature, humidity, fine dust, volatile organic compounds, formaldehyde, bacteria, fungus, house dust mite, endotoxin. Results: According to the survey results, 9 patients (10%) were treated with asthma, 6 (6.7%) were asthmatic patients during the past 12 months, and 4 patients (4.4%) were asthmatic patients during the past 12 months. There were statistically significant differences in the direct effect of smokers in the family (P=0.0328). High-filter vacuum cleaners collected $0.4222CFU/m^3$ in subjects without asthma, and $0.2222CFU/m^3$ in subjects with asthma. In addition, various results confirmed that asthma exacerbated by mold exposure. Conclusions: The results of this study suggest that exposure to fungal by infants and toddlers may play an important role in the development of asthma. In this study, we investigated the relationship between asthma and fungal concentration.

  • PDF

Comparison of Intradermal Skin Test and Multiple Allergen Simultaneous Test Results in Canine Atopic Dermatitis

  • Nam, Hyeyeon;Yun, Taesik;Koo, Yunhoi;Lee, Dohee;Chae, Yeon;Park, Jooyoung;Choi, Dongjoon;Kim, Hakhyun;Yang, Mhan-Pyo;Kang, Byeong-Teck
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.120-126
    • /
    • 2021
  • Intradermal skin test (IDST) is generally considered a useful tool in identifying causal allergens in canine atopic dermatitis. Currently, multiple allergen simultaneous test (MAST), an in vitro testing method for allergen-specific immunoglobulin E, is being used as an alternative method. However, there are no reports comparing the IDST and MAST results in the same dogs. This study compared the results of both tests to evaluate the agreement and correlation between them. The sensitivity, specificity, and accuracy of the MAST were 76.2%, 64%, and 66.7%, respectively. Moderate positive predicted value (PPV, 50-75%) or high sensitivity (80-100%) were identified for indoor allergens, such as cat epithelia, house dust, and house dust mites. In contrast, high negative predicted value (NPV, 93.3-100%) and specificity (60-100%) were observed for environmental allergens and fungi. Although the agreement between IDST and MAST for all allergens was fair (κ = 0.301), that for each allergen was poor (κ < 0.01), except for birch (κ = 0.158). Spearman's rank correlation analysis revealed a low correlation between the MAST and IDST results (ρ = 0.308, p = 0.001). As compared to the IDST results, the MAST results did not identify the causative allergens sufficiently. IDST may not be performed for environmental allergens and fungi with high NPV and specificity if the MAST result is negative, but it may have to be performed for indoor allergens with moderate PPV and high sensitivity when the MAST result is positive.

Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station (서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가)

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Jangwon;Jo, Kyung-Ho;Jung, Eulgyu;Kim, Inkyu;An, Yeonsun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

Study on the Evaluation Criteria of Termite Dust for Rapid Control of Wooden Structures Damaged by Termites (흰개미 가해 목조건축물의 급속 방제를 위한 분말형 약제(Termite Dust) 평가 기준 연구)

  • Im, Ik Gyun;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.3
    • /
    • pp.227-235
    • /
    • 2019
  • In Korea, various methods are applied to prevent wooden structures from being damaged by termites. However, since there is no way to quickly bring toxic substances in contact with the termites inside the timber, it leads to the damage of wooden cultural property due to the prolonged period of controlling the termites. Accordingly, an indoor evaluation criteria study was conducted for the introduction of powder-type termiticides in Korea, which produced rapid control effects by drilling wood and directly contacting and transferring toxic substances inside the timber. First, contact toxicity and transfer ability of termite dusts were evaluated to establish the criteria for evaluation of effectiveness against Reticulitermes speratus. The contact toxicity confirmed 100% mortality of fipronil, deltamethrin and cyfluthrin termite dusts within 24 h of contact; however, differences occurred in the active ingredient transfer time to the sublethal. In addition, in the case of transfer ability evaluation, the rate of mortality gradually decreased under 1:9 and 1:25 ratio conditions; however, the difference in the reduction rate was identified depending on the type of termite dust. the results of the evaluation of compressive strength of the wood showed that the difference in the measured values between the control group and the conditions of perforation 1 to 3 times, which does not significantly affect the compressive strength of wood. In this study, the criteria of termite dust selection and evaluation method of dust-type termiticides were presented and the applicability of the method was identified.