• Title/Summary/Keyword: Indoor characteristics

Search Result 1,160, Processing Time 0.022 seconds

An Analysis on Characteristics of the Pollutants and the Real Condition State of the Indoor Air Pollution in Occupied Apartment Units (기존 공동주택의 실내 유해화학물질 오염발생원에 대한 특성 분석)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.11-18
    • /
    • 2010
  • The aims of this study were to grasp the real condition state and clarify the characteristics and influence of pollutants on the indoor air pollution in occupied apartment units. The research method was to measure the pollution levels of indoor air pollution, and investigate characteristics of the pollutants such as the outdoor environment, elapsed time after construction, finished materials, temperature, relative humidity, space extension, purchase with furniture and electric appliances, built-in closets, and method for cleaning the air. And these were made a comparition between industrial and residential area. The VOCs and formaldehyde concentration in indoor air were measured the 6 household in residental area and 5 household in industrial area. In conclusion, the concentration such as benzene, ethylbenzene, toluene, xylene, styrene showed the pollution state within permissible levels, however formaldehyde concentration has need a lot of attention as ever. And it turned out that the influence with reference to emission from building materials on indoor air pollution lessened under 18 months elapsed time after construction.

The Influence of Air Pollution Level on Resident's Evaluation and Cognition for Indoor Environment in Ulsan (울산지역의 대기오염 환경의 차이가 거주자의 실내환경 평가 및 인식에 미치는 영향)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.87-94
    • /
    • 2010
  • The aim of this study was to evaluate the influence of air pollution level in industrial and residential district of Ulsan on resident's evaluation and cognition for indoor environment. The evaluation of air pollution materials (as $SO_2$, $NO_2$, $O_3$, CO, PM10) were investigated to understand the distributional characteristics in survey area, and air quality monitoring data from 2007 to 2009 were used. The data was applied in a realtime measurement of industrial and residential area respected to difference of the pollution level in Ulsan. The questionnaire of this survey for resident's cognition was to find out characteristics on perception of indoor environment and outdoor air quality recognition based on the distinct characteristics of the areas. The results of this study shows that resident's satisfaction at clean level outdoor air and indoor environment were different whether it was residential area or industrial area and outdoor air pollution level has direct influence on resident's satisfaction in indoor environment.

A Review of Scientific Evidence on Indoor Air of School Building: Pollutants, Sources, Health Effects and Management

  • Chithra, V.S;Shiva, Nagendra S.M
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.87-108
    • /
    • 2018
  • Schools are one of the critical social infrastructures in a society, the first place for social activity and the most important indoor environment for children besides the home. Poor IAQ in classrooms can increase the chance of long-term and short-term health problems for students and staffs; affects productivity of teachers; and degrade the student learning environment and comfort levels. The primary objective of this paper is to review and summarize available scientific evidence on indoor air quality of schools and related health effects in children. It was found that the indoor air pollutant levels in school buildings varied over a wide range in different parts of the world depending on site characteristics, climatic conditions, outdoor pollution levels, occupant activities, ventilation type and building practices. Among the indoor air pollutants, particulate matter concentrations were found to be very high in many schools. Outdoor pollutant sources also play a major role in affecting the IAQ of the school building. Hence, scientific knowledge on sources of indoor pollutants, quantification of emissions, temporal and spatial dispersion of pollutants, toxicological properties, chemical and morphological characteristics of the pollutants and associated health risk among children in the school buildings are essential to evaluate the adequacy and cost effectiveness of control strategies for mitigating the IAQ issues.

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement) (교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구))

  • Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

Analysis on Characteristics of Thermal Flow for Heating Indoor Space by Air-heating Collector using Solar Heat (태양열 공기가열 집열기에 의한 난방 실내공간의 열유동 특성 해석)

  • Yang, Young-Joon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.271-278
    • /
    • 2022
  • The solar energy has been widely used to reduce the fossil fuel and prevent the environmental pollution. The renewable energy including solar heat tends to spread due to carbon neutrality for main country of the world. Targets of solar collector are usually acquisitions of hot water or hot air. Especially, air-heating collector using solar heat is known as the technology for obtaining hot air. This study aims to investigate of characteristics of thermal flow when the hot air by air-heating collector using solar heat flows inside of indoor space. The thermal flow of heating indoor space was simulated using ANSYS-CFX program and thus the behaviors of hot air in indoor space were evaluated with standard k-𝜀 turbulence model. As the results, as the inlet velocity was increased, the behaviors of hot air became simple, and temperature range of 25~75℃ had almost no effect on behavior of flow. As the inlet temperature was increased, the temperature curve of indoor space from bottom to top was changed from linear to quadratic. Furthermore, it was confirmed that inlet velocity as well as inlet temperature also should be considered to heat indoor space equally by air-heating collector using solar heat.

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

Actual State and Characteristics of Indoor Noise Including Residents' Living in Apartment Units (아파트 단위주거 내부생활소음의 특성과 실태)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.1
    • /
    • pp.83-90
    • /
    • 2009
  • The present study is a preliminary research improving the dwelling quality of apartment house as a kind of multi-family housing. The purpose of the study is to find out the actual state on characteristics of indoor noise including residents' living in apartment units. The method was field survey consisted of field measurements on equivalent noise level, observation on noise type, and interview on residents' responses. Field survey were carried out in 20 occupied apartment units from January to March 2007. The results are as follows. 1) Averages of indoor noise levels including residents' living noise were measured as $43.9{\sim}62.2\;dB(A)_{Leq5min}$, the average of each house except one was higher than the permissible level, 45 dB(A). 2) The noise types observed were mostly residents' living noise and classified into 'water hammer', 'living equipment noise', 'noise by family', 'hood noise', 'kitchen noise' in own unit, 'walking and talking noise in stairs and corridors', 'noise by neighborhood house', 'noise by the upper story' in building, and outdoor noise. 3) The residents showed slightly non-positive responses at 'noise by the upper story', 'noise by neighborhood house', 'water hammer', and 'noise by family'. Therefore, it is required to plan for preventing deterioration of the dwelling quality by residents' living noise in own unit as well as by neighborhood houses.

Analysis of Indoor Air Quality in vulnerable facilities according to building characteristics (민감시설의 건물 특성에 따른 실내공기질 분석)

  • Cho, Kyunghwa;Kwon, Soonjung;Sung, Minki;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: With the increasing of public-use facilities, there has been a growing concern over Indoor Air Quality(IAQ) of public-use facilities. Because the facilities are easy to be exposed to indoor air pollutants, they needs to be periodically managed the IAQ. Methods: In this study, indoor air pollutant concentrations of 24 vulnerable facilities were measured and compared. The measurements were conducted for pollutants which are defined in 'IAQ Control In Public-Use Facilities, etc. Act'. We took two measurements, the first was carried out in summer and the second was proceeded in winter. We analyzed the values according to the type of facilities and pollutants. Results: There was a difference in pollutant concentrations by the season and in occurrence characteristics by the measurement spot. Therefore, we need to manage pollutant concentrations by characteristics of occurrence. Implications: Based on the comparative analysis of pollutant concentrations, we suggested cause and improvement strategies for IAQ management of Vulnerable facilities.

A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics (바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.