• Title/Summary/Keyword: Indoor and outdoor concentrations

Search Result 182, Processing Time 0.024 seconds

A Survey of Indoor and Outdoor Radon Concentrations by Alpha Track Detector in Korea (Alpha Track Detector를 이용한 실내외 라돈 농도조사에 관한 연구)

  • ;;;Takao Iida
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.71-76
    • /
    • 2002
  • A survey of radon concentrations in both indoor and outdoor atmospheres was carried out using EIRM and Cup Monitor for the period of February 1996 to March 1997. EIRM were used to measure the indoor and outdoor radon concentration at five major cities university. Cup Monitor were also used to measure the indoor radon concentrations at shopping store, office building, apartment, hospital and house in Seoul. The mean indoor and outdoor radon concentrations at the five major cities(Seoul, Daegu, Daejon, Cwangiu and Busan) were 24.1 Bq/m$^3$and 8.62 Bq/m$^3$, respectively. The ratio of indoor to outdoor radon concentrations ranged front 1.7 to 3.9. Inspection of its seasonal distribute pattern indicates the enhancement during winter relative to summer, consistently for both indoor and outdoor air. The results of the survey showed that the concentrations in basements were clearly higher than those in usual living/working places.

A Survey of Indoor and Outdoor Radon Concentrations in Five Major Cities (주요 5개 도시의 실내외 라돈농도 조사연구)

  • ;;;Takao lida
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.75-82
    • /
    • 2002
  • This outline survey of indoor and outdoor radon concentrations in five major cities in Korea was carried out with Electrostatic Integrating Radon Monitor(EIRM) from February to December, 1996 and January to december, 1998. The mean indoor and outdoor radon concentrations in five major cities in 1996 were $21.9{\;}Bq/\textrm{m}^3$ and $9.6{\;}Bq/\textrm{m}^3$, respectively. The mean indoor and outdoor radon concentrations in 1998 were $20.8{\;}Bq/\textrm{m}^3$ and $9.0{\;}Bq/\textrm{m}^3$, respectively. These were below the U.S.EPA radon action level. The range of indoor to outdoor radon concentrations were $0.8{\;}Bq/\textrm{m}^3{\;}~{\;}45.6{\;}Bq/\textrm{m}^3$ in 1996, $0.5{\;}Bq/\textrm{m}^3{\;}~{\;}15.2{\;}Bq/\textrm{m}^3$ in 1998, respectively. The result of our analysis showed that radon concentrations in indoor air were clearly higher than those in outdoor air. Inspection of seasonal distribute pattern indicates the enhancement during winter relative to summer.

Relationship between Indoor and Outdoor Particulate Matter Concentrations in Japan

  • Nakai, Satoshi;Tamura, Kenji
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.68-74
    • /
    • 2008
  • We briefly show the results of indoor and personal $PM_{2.5}$ measurements in an epidemiologic study designed to evaluate the health risks of ambient $PM_{2.5}$ in Japan and the relationship between indoor and outdoor PM concentrations. The impact of indoor and outdoor PM pollution on health is described based on one morbidity study. The results of other studies on indoor $PM_{2.5}$ measurements are also described.

Heavy Metal Contamination of Indoor, Outdoor and Playground in Middle and High School in the Jeonju-City, Korea (전주시내 중고등학교 실내.외 환경의 중금속 오염에 대한 연구)

  • 조규성
    • Journal of Environmental Science International
    • /
    • v.9 no.6
    • /
    • pp.495-503
    • /
    • 2000
  • Dust samples were collected from 17 middle and high schools in the Jeonju-city. heavy metal concentrations were determined for the dry-deposited dusts from indoor and outdoor of classroom and playground of each sampling site. Concentrations of Cd, Cr, Cu, Ni, Pb and Zn in indoor\`s dusts were highly concentrated. Also heavy metal concentrations in outdoor\`s dusts were similar to that of indoor\`s dusts. Concentrations of Cd, Cu, and Zn in the dusts were much higher than the world average contents in soil and environmental orientation value. These levels are similar to those of the dust samples at middle schools located at Kangseo-gu and Yangchon-gu , Seoul. Playground dusts in 6 schools exhibited the enhanced heavy metal pollution with a pollution index (by Kloke) greater than 1.0. Most indoor and outdoor dusts exhibited the enhanced heavy metal pollution with a pollution index(by Cullbard et al.) greater than 1.0.

  • PDF

Personal, Indoor and Outdoor $NO_2$ Measurements in an Urban Area (二酸化窒素의 室內外 濃度 및 個人被暴量에 관한 調査硏究)

  • 金潤信;柳澤 幸雄
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.33-38
    • /
    • 1987
  • A pilot study on indoor air concentrations of nitrogen dioxide $(NO_2)$ was undertaken in the Seoul area, Korea dudring February-April 1986. Indoor and outdoor data on nitrogen dioxide concentrations were obtained for 48 private residences. Personal exposure to $NO_2$ was also investigated. Indoor outdoor ratio of $NO_2$ concentrations was 0.87, while the correlations between the indoor and outdoor levels were less than 0.50 for $NO_2$. Homes with an unvented space heater had average living room $NO_2$ concentrations approximately double those with a vented space heater. Residences with smokers have significantly higher living room $NO_2$ levels than those without smokers.

  • PDF

Measurements of Indoor and Outdoor Volatile Organic Compounds(VOCs) Concentrations in Ambient Air (실내외 공기중 휘발성 유기화학물질(VOCs)의 농도조사에 관한 연구)

  • 신혜수;김윤신;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.310-319
    • /
    • 1993
  • A pilot study was conducted in order to investigate the concentrations of indoor and outdoor VOCs (Volatile Organic Compounds) at ten homes and four building offices in Seoul during March-April, 1993. The five components of VOCs(Benzene, Toluene, Ethylbenzene, o-Xylene, m/p-Xylene) were collected using charcoal tube and were analysed using Gas Chromatography(GC) with a Flame Ionization Detector(FID). The mean concentations of indoor VOCs were shown as Benzene of 38.9 .mu.g/m$^{3}$. Toluene of 165.0 .mu.g/m$^{3}$, Ethylbenzene of 21.7 .mu.g/m$^{3}$, o-Xylene of 11.6 .mu.g/m$^{3}$ and m/p-Xylene of 29.3 .mu.g/m$^{3}$, but those corresponding that indoor levels of VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs concentrations was 0.99 for Benzene, 1.23 for Toluene, 5.86 for Ethylbenzene, 5.23 for o-Xylene, 2.41 for m/p-Xylene in homes, while 2.02 for Benzene, 1.15 for Toulene, 0.96 for Ethylbenzene, 1.41 for o-Xylene, 1.38 for m/p-Xylene in offices, respectively. The mean concentrations of VOCs in homes were higher than those levels in offices, while the mean concentration of VOCs during active hour of occupants in a day were higher 1-3 times than the levels during non-active hour. Comparing VOCs levels by building's age, the mean concentrations of Benzene, o-Xylene and m/p-Xylene were higher in new building than old building, but the mean concentrations of Toluene and Etylbenzene in new building were lower than old building. The mean concentrations in all components of VOCs in smoking area were higher than non-smoking area. These results suggested that the VOC levels were affected by various indoor characteristics and behavioral activity of occupants.

  • PDF

Indoor Air Quality of Acidic Air Pollutants at a Private House in Seoul During the Spring Months

  • Lee, Hak-Sung;Kang, Byung-Wook;Kang, Choong-Min;Yeo, Hyun-Gu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E3
    • /
    • pp.109-115
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality at a private house in Seoul during the spring period. All indoor and outdoor samples were measured simultaneously using an annular denuder system. The data set was collected on twelve different days with a 24-hr sampling period in April and May 1997. The chemical species measured were HN $O_3$, HN $O_2$, S $O_2$ and N $H_3$in the gas phase and P $M_{2.5}$ (dp 2.5 ${\mu}{\textrm}{m}$), S $O_4$$^{2-}$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ in the particulate phase. Indoor concentrations of HN $O_2$, N $H_3$, and P $M_{2.5}$ were greater than outdoor levels. However, indoor concentrations of HN $O_3$, S $O_2$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ were less than those found from outdoors. In the case of S $O_4$$^{2-}$, the indoor and outdoor concentrations were similar. Indoor concentrations of P $M_{2.5}$ , S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were dependent upon the outdoor concentrations. A tracer-gas decay technique with sulfur hexafluoride (S $F_{6}$ ) as the tracer gas was used to estimate the air exchange rate of a private home in the spring. The average air exchange rate was computed to be 2.87 h $r^{-1}$ .X> .

  • PDF

Temporal Characteristics of Selected Volatile Organic Compounds in Urban High-Stories Urban Apartments

  • Shin, Seung Ho;Kim, Ji-Hoon;Jo, Wan Kuen
    • Journal of Environmental Science International
    • /
    • v.24 no.10
    • /
    • pp.1273-1283
    • /
    • 2015
  • In present study, the temporal characteristics of nine selected volatile organic compounds (VOCs), including four alcohol, 2 aldehyde, and 3 ketone compounds, in high-stories urban apartments over a 2-y period were investigated. The indoor VOC concentrations had generally a decreasing trend over the 2-y follow-up period. For examples, the 2E1H indoor concentration decreased from $10.8{\mu}g/m^3$ for the first two months to $5.1{\mu}g/m^3$ for the last two months. In addition, the DCA and ACT indoor concentrations decreased from 5.0 and $14{\mu}g/m^3$ for the first two months to 2.2 and $6.4{\mu}g/m^3$, respectively, for the last two months. The indoor-to outdoor concentration ratios over the 2-y period were much greater than 1, indicating that indoor VOC concentrations were higher than the outdoor VOC concentrations. Similar to those of the individual VOCs, the indoor-to-outdoor concentration ratios of all three VOC groups were higher than 1 over the 2-y follow-up period, suggesting higher indoor concentrations of the three VOC groups than outdoor concentrations. In consistence with the results of VOC indoor concentrations, the VOC emission rates decreased gradually as time passed, due to the decreased VOC emission strengths of indoor sources. Finally, there was an initial sharp decrease in the indoor VOC concentrations followed by a slower decrease, indicating a multi-exponential decay model for the target VOCs, which was demonstrated by comparison of the residuals and the adjusted coefficient of determination associated with the one and two-exponential fits of each data set.

Indoor, Outdoor, and Personal Exposure to Nitrogen Dioxide Comparing Industrial Complex Area with Country Area (공단지역과 시골지역 주택 실내, 실외 및 개인의 이산화질소 노출평가)

  • Yang, Won-Ho;Im, Sung-Guk;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.183-187
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay, and outdoor levels. Various indoor and out-door combustion sources produce nitrogen dioxide ($NO_2$), which is a by-product of high temperature fossil fuel combustion. Especially, the presence of gas ranges and smoking have been identified as major factors contributing to indoor $NO_2$ exposures. In this study, we compared an industrial complex area with a country area by assessing the personal exposure to $NO_2$with measurements of indoor and outdoor $NO_2$ levels in residences and by house characteristics and questionnaire. Personal exposure concentrations were significantly correlated with indoor $NO_2$ concentrations of residences in both the industrial complex area and the country area with correlation coefficients of 0.561 and 0.664, respectively, compared to outdoors. Multiple regression analysis, indicated that indoor $NO_2$ levels in residences were only affected by outdoor levels (p = 0.000) in spite of higher indoor sources such as smoking. Therefore, it is suggested that outdoor air quality as well as indoor air quality should be considered in the reduction of the personal exposure to air pollutants.

Variation of Indoor Air Quality in Museum (박물관 실내공기질 변동에 관한 연구)

  • 이정주;김신도;부문자
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.43-48
    • /
    • 1996
  • Indoor air quality(IAQ) in museum is very important for protection of cultural properties. In our study, we measured air pollutants($NO_x, NH_3, SO_2, O_3$, CO, $CO_2$, TSP), temperature and humidity to evaluate IAQ of national central museum. Indoor carbon dioxide and TSP concentrations were higher than outdoor concentrations. Temperature, huinidity and TSP had large deviation depending on air conditioning operates or not. Indoor gas phase pollutants except $CO_2$ were lower than outdoor concentrations, but $SO_2$ concentration was high in storage. $CO_2$ and TSP were influenced by the number of spectators.

  • PDF