• 제목/요약/키워드: Indoor air quality(IAQ)

검색결과 187건 처리시간 0.023초

실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과 (The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots)

  • 박정호
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

A Numerical Investigation of Indoor Air Quality with CFD

  • Sin V. K;Sun H. I
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.207-208
    • /
    • 2003
  • Increasing interest in indoor air quality (IAQ) control has been found because of its serious effect on human health. To evaluate IAQ, thermal comfort in terms of temperature and velocity distributions of indoor air has to be analyzed in detail. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In this paper, we present a discussion on the proper location of the air-conditioner in order to obtain good thermal comfort for occupant of a typical bedroom in Macao. A set of carefully designed numerical experiments is run with the Computational Fluid Dynamics (CFD) software FLOVENT 3.2 [1]. Reynolds averaged Navier-Stokes equations are solved with finite volume technique and turbulence effects upon the mean flow characteristics is modeled with the k - & model. Assumption of steady state environment is made and only convective and conductive heat transfer from the occupant and air-conditioner are being concerned.

  • PDF

초등학교 교실공기질의 특징과 제어방안에 관한 연구 (Study on the Characteristics of Air quality in the Classroom of Elementary School and Its Control Methods)

  • 정지원;이희관
    • 대한환경공학회지
    • /
    • 제32권4호
    • /
    • pp.311-322
    • /
    • 2010
  • The common life with modern urban residence, spending more than 80~90% of daily life in indoor environment, makes the importance of indoor air quality (IAQ) even higher. Many efforts have made to improve indoor air quality (IAQ), which requires those systematic approaches for field practice. A recent study reported that no general approach cannot be made for IAQ improvement due to the great deal of variety in different indoor environments. Those indoor spaces included in Korean IAQ regulation were classified based on their characteristics and the IAQ guideline was suggested for each group of indoor spaces. Apart from those indoor spaces, the classroom in elementary school has different characteristics. By introducing the systematic approaches, the elementary classroom was surveyed and analyzed to understand its characteristics in due IAQ consideration. Based on the characteristics, there are several IAQ control measures suggested, including ventilation operation, dust mat installation, and white board. $CO_2$ and airborne dust were monitored and analyzed in order to evaluate the effectiveness of each control measure to IAQ. It was found that the general level of $CO_2$ concentration was managed under the IAQ guideline by applying the ventilator operation. The ventilation was also effective to the fugitive airborne particulate in elementary classroom environment.

실내공기질 모델을 이용한 환기 시스템의 공기 정화 효율성 평가 (Evaluation of Ventilation System Performance Using Indoor Air Quality Model)

  • 최성우
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.57-66
    • /
    • 1997
  • Successful energy conservation and good indcfor air quality (IAQ) are highly dependent on ventilation system. Air filtration is a primary solution of indoor air control strategies in terms of reducing energy consumption and improving ihdoor air quality. A conventional system with bypass filter, as it is called variable-air-volume/bypass filtration system (VAV/BPFS), is a variation of the conventional variable air volume (VAV) systems, which is designed to eliminate indoor air pollutant and to save energy. Bypass filtration system equipped with a high-efficiency particulate filter and carbon absorbent provides additional cleaned air into indoor environments and maintain good IAQ for human health. The objectives of this research were to compare the relative total decay rate of indoor air pollutant concentrations, and to develop a mathematical model simulating the performance of VAV/BPFS. All experiments were performed in chamber under the controlled conditions. The specific conclusions of this research are: 1. The VAV/BPFS system is more efficient than the VAV system in removing indoor air pollutant concentration. The total decay rates of aerosol, and total volatile organic compound (TVOC) for the VAV/BPFS system were higher than those of the conventional VAV system. 2. IAQ model predictions of each pollutant agree closely with the measured values. 3. According to IAQ model evaluation, reduction of outdoor supply air results in decreased dilution removal rate and on increased bypass filtration removal rate with the VAV/BPFS. As a results, we recommends the VAV/BPFS as an alternative to conventional VAV systems.

  • PDF

박물관 실내공기질 변동에 관한 연구 (Variation of Indoor Air Quality in Museum)

  • 이정주;김신도;부문자
    • 한국환경보건학회지
    • /
    • 제22권4호
    • /
    • pp.43-48
    • /
    • 1996
  • Indoor air quality(IAQ) in museum is very important for protection of cultural properties. In our study, we measured air pollutants($NO_x, NH_3, SO_2, O_3$, CO, $CO_2$, TSP), temperature and humidity to evaluate IAQ of national central museum. Indoor carbon dioxide and TSP concentrations were higher than outdoor concentrations. Temperature, huinidity and TSP had large deviation depending on air conditioning operates or not. Indoor gas phase pollutants except $CO_2$ were lower than outdoor concentrations, but $SO_2$ concentration was high in storage. $CO_2$ and TSP were influenced by the number of spectators.

  • PDF

공동주택용 환기장치의 실내공기질 개선효과에 대한 현장실험연구 (Field Studies on the Improvement of Indoor Air Quality by Ventilator in Apartment Houses)

  • 성기철;장현재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.202-211
    • /
    • 2007
  • Ventilation system is being recommended as an effective tool to improve indoor air quality (IAQ) in apartment houses. Recently, in Korea, apartment house suppliers must establish ventilation system in apartment houses in law. In this study, improvement of IAQ by establishing mechanical ventilation system at apartment house was investigated by mockup test. Seven apartment houses were arranged for the test and improvement of IAQ was examined under the various conditions of ventilation rates, ventilator type and duct works. The results of this study show that IAQ in the test houses which were established mechanical ventilation system was improved about from 30% to 40% compared with IAQ in the apartment house which was not established ventilation system. However, there were no apparent concentration differences between the cases of changing ventilation rates, ventilator types and ductworks.

Influence Factors and Management based on Phase of Building Construction for the Improvement of Post Occupancy Indoor Air Quality

  • Lim, Hyoung-Chul
    • 한국건축시공학회지
    • /
    • 제11권6호
    • /
    • pp.576-586
    • /
    • 2011
  • In recent years, pollution in residential spaces has been a significant area of concern. In particular, the indoor air quality (IAQ) of an apartment building before occupancy, which is related to the interior material, is a serious problem. Unlike previous research, which has mainly focused on pollution control after construction, this study has derived influencing factors and priority of management with a controlling schedule for IAQ. The objectives of this research are 1) control of schedule or improvement of management for IAQ, 2) distribution of responsibility to the parties concerned (factory, material company, construction company, design and engineering, occupancy). The results show the relative priority of the four major items in wall?based apartment buildings and in column?based apartment buildings. An analysis of the parties responsible for improvement based on the IAQ results shows more efforts to improve IAQ are needed in material factories and engineering/design companies.

주거건축의 IAQ에 관한 연구 (A Study on Evaluation of IAQ in Dwelling House)

  • 박미진
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.108-112
    • /
    • 1997
  • Recently, the use of Dwelling House has been expanded due to the rapid urbainzation and congestion of population in City. Indoor Air Quality in apartment houses was investigated by measuring pollutants such as $CO_2$ gas, dust concentration. In this study, the mesurements of indoor air environment were performed in Dwelling house in Seoul area to investigate indoor air environment and the relation of air contaminative and the response level. Indoor air contamination and living environment of the occupants have been compared & analyzed with practical investigation of IAQ in Seoul, Korea and Tokyo, Japan.

  • PDF

민감시설의 건물 특성에 따른 실내공기질 분석 (Analysis of Indoor Air Quality in vulnerable facilities according to building characteristics)

  • 조경화;권순정;성민기;김선숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권2호
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: With the increasing of public-use facilities, there has been a growing concern over Indoor Air Quality(IAQ) of public-use facilities. Because the facilities are easy to be exposed to indoor air pollutants, they needs to be periodically managed the IAQ. Methods: In this study, indoor air pollutant concentrations of 24 vulnerable facilities were measured and compared. The measurements were conducted for pollutants which are defined in 'IAQ Control In Public-Use Facilities, etc. Act'. We took two measurements, the first was carried out in summer and the second was proceeded in winter. We analyzed the values according to the type of facilities and pollutants. Results: There was a difference in pollutant concentrations by the season and in occurrence characteristics by the measurement spot. Therefore, we need to manage pollutant concentrations by characteristics of occurrence. Implications: Based on the comparative analysis of pollutant concentrations, we suggested cause and improvement strategies for IAQ management of Vulnerable facilities.

교육시설물의 실내공기질 측정 및 개선방안에 관한 연구 (A study on the Measurement and Improving Method of Indoor Air Quality in a Educational Facility)

  • 김성겸;김재온;조창연;김종록;손재호
    • 교육시설
    • /
    • 제14권4호
    • /
    • pp.43-52
    • /
    • 2007
  • People spend more than 90% of their time indoor. Nowadays as they are interested in environment much more than before, indoor air pollution has been regarded as new environmental problems. At present, an air quality check is required prior to the completion of construction. However this study shows that the density level of HCHO and VOCs in a classroom was increased after furnishing the classroom. Thus, to measure the quality of air more effectively and accurately, it should be measured after the indoor space are furnished. Newly-built schools are tested for this study. The building sites were investigated to measure and evaluate the IAQ (Indoor Air Quality) in newly-built schools. The result of this study can be used as a basis to improve the environment air condition of the educational facilities.