초고층 공동주택의 세대별 냉난방부하 시뮬레이션 결과 및 에너지 실사용량과의 비교 분석 (A Comparative Analysis of Energy Simulation Results and Actual Energy Consumption on Super High-rise Apartments)

  • 서혜수;김병선
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.34-40
    • /
    • 2011
  • Apartment Housing has been increasing steadily, particularly our current super high-rise apartment houses that represent the culture has become a trend in Korea. These super high-rise apartment houses' curtain wall system increases heating and cooling loads, it is expected to vary by each unit's thermal properties. In this study, measured indoor environment and energy simulation results were compared to actual energy consumption. As a result, the various factors that affect heating and cooling loads, such as direction, plan type and glazing area, influence each unit's load characteristic. In particular, according to the electricity costs savings behavior, the occupant's thermal discomfort is expected to be large in summer. Therefore, to reduce heating and cooling load for each unit requires a reasonable plan.

PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating)

  • 장민;정동일;정종호;김용찬
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.537-543
    • /
    • 2015
  • Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of $26^{\circ}C$ after adopting the PCM unit for continuous heating during the defrosting operation.

BLE Beacon Plate 기법과 Pedestrian Dead Reckoning을 융합한 실내 측위 알고리즘 (Indoor Positioning Algorithm Combining Bluetooth Low Energy Plate with Pedestrian Dead Reckoning)

  • 이지나;강희용;신용태;김종배
    • 한국정보통신학회논문지
    • /
    • 제22권2호
    • /
    • pp.302-313
    • /
    • 2018
  • 스마트 기기의 생활화와 증강현실 활용 증가로 실내 위치 인식 시스템의 수요가 급증함에 따라, BLE(Bluetooth Lower Energy) 비콘 그리고 UWB(Ultra Wide Band) 등을 이용한 실내 측위 시스템이 개발되고 있다. 본 논문에서는 BLE Beacon을 기반으로 RSSI(Received Signal Strength Indicator)를 이용한 삼변측량(Trilateration) 기법을 사용하여 측위 플레이트(Plate)를 생성한다. 이에 IMU(Inertial Measurement Unit) 센서의 방향, 속도, 이동거리 등의 데이터를 이용하여 PDR(Pedestrian Dead Reckoning) 측위 좌표를 산출하여 정확도를 보정한다. 또, BLE 비콘(Beacon)의 RSSI를 적용한 플레이트(Plate) 기법과 PDR 기법이 융합된 정밀 실내 측위 알고리즘을 제안한다. 본 논문에서 제시한 알고리즘을 실제 대형 실내 경기장과 공항에 BLE 비콘을 설치, 실험하여 평균 2.2m 의 오차로 65%의 정확도가 개선됨을 검증하였다.

Pseudolite/Ultra-low-cost IMU Integrated Robust Indoor Navigation System Through Real-time Cycle Slip Detection and Compensation

  • Kim, Moon Ki;Kim, O-Jong;Kim, Youn Sil;Jeon, Sang Hoon;No, Hee Kwon;Shin, Beom Ju;Kim, Jung Beom;Kee, Changdon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제6권4호
    • /
    • pp.181-194
    • /
    • 2017
  • In recent years, research has been actively conducted on the navigation in an indoor environment where Global Navigation Satellite System signals are unavailable. Among them, a study performed indoor navigation by integrating pseudolite carrier and Inertial Measurement Unit (IMU) sensor. However, in this case, there was no solution for the cycle slip occurring in the carrier. In another study, cycle slip detection and compensation were performed by integrating Global Positioning System (GPS) and IMU in an outdoor environment. However, in an indoor environment, cycle slip occurs more easily and frequently, and thus the occurrence of half cycle slip also increases. Accordingly, cycle slip detection based on 1 cycle unit has limitations. Therefore, in the present study, the aforementioned problems were resolved by performing indoor navigation through the integration of pseudolite and ultra-low-cost IMU embedded in a smartphone and by performing half cycle slip detection and compensation based on this. In addition, it was verified through the actual implementation of real-time navigation.

중소도시 공동주택의 실내공기질(새집증후군) 실측에 관한 연구 (Field Measurements of Indoor Air Quality in Apartment Units at Medium-size Cities)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.81-86
    • /
    • 2010
  • The main sources of the new house syndrome(sometimes it called sick building syndrome) are a concentration of formaldehyde (HCHO) and a concentration of total volatile organic compounds(TVOC). I had field measurements of indoor air quality in the apartment unit at medium-size cities(Y city, C city). I measured indoor air temperature, HCHO concentration in 16 units, TVOC concentration in 6 units and air tightness in 7 units. And I measured outdoor air quality, HCHO concentration and TVOC concentration. Mean concentration of HCHO was $357{\mu}g/m^3$(2006 standard=$120{\mu}g/m^3$), mean concentration of TVOC was $3,092{\mu}g/m^3$ and mean effective air leakage area was 193 cm2. There was a close relation between the indoor air temperature and HCHO concentration, between the indoor air temperature and TVOC concentration. Air tightness also had relation.

모바일로봇의 정밀 실내주행을 위한 개선된 ORB-SLAM 알고리즘 (Modified ORB-SLAM Algorithm for Precise Indoor Navigation of a Mobile Robot)

  • 옥용진;강호선;이장명
    • 로봇학회논문지
    • /
    • 제15권3호
    • /
    • pp.205-211
    • /
    • 2020
  • In this paper, we propose a modified ORB-SLAM (Oriented FAST and Rotated BRIEF Simultaneous Localization And Mapping) for precise indoor navigation of a mobile robot. The exact posture and position estimation by the ORB-SLAM is not possible all the times for the indoor navigation of a mobile robot when there are not enough features in the environment. To overcome this shortcoming, additional IMU (Inertial Measurement Unit) and encoder sensors were installed and utilized to calibrate the ORB-SLAM. By fusing the global information acquired by the SLAM and the dynamic local location information of the IMU and the encoder sensors, the mobile robot can be obtained the precise navigation information in the indoor environment with few feature points. The superiority of the modified ORB-SLAM was verified to compared with the conventional algorithm by the real experiments of a mobile robot navigation in a corridor environment.

컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구 (An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer)

  • 조진호;이대우
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

iPhone의 LiDAR와 Camera를 이용한 실내 공간 안내를 위한 시스템 설계 (Design of Indoor Space Guidance System Using LiDAR and Camera on iPhone)

  • 장준석;성광제
    • 반도체디스플레이기술학회지
    • /
    • 제23권1호
    • /
    • pp.71-78
    • /
    • 2024
  • In indoor environments, since global positioning system (GPS) signals can be blocked by obstacles, such as building structure. the performance of GPS-based positioning methods can be degraded because of the loss of GPS signals. To solve this problem, various localization schemes using inertial measurement unit (IMU) sensors, such as gyroscope, accelerometer, and magnetometer, have been proposed to enhance the positioning accuracy in indoor environments. IMU-based positioning methods can estimate the location of the user by calculating the velocity and heading angle of the user without the help of GPS. However, low-cost MEMS IMUs may lead to drift error and large bias. In addition, positioning errors in IMU-based positioning approaches can be caused by the irrelevant motion of the pedestrian. In this study, we propose an enhanced indoor positioning method that provides more reliable localization results by using the camera, light detection and right (LiDAR), and ARKit framework on the iPhone. Through reliable positioning results and augmented reality (AR) experiences, our indoor positioning system can provide indoor space guidance services.

  • PDF

데이터 기반 모델에 의한 강제환기식 육계사 내 기온 변화 예측 (Data-Based Model Approach to Predict Internal Air Temperature in a Mechanically-Ventilated Broiler House)

  • 최락영;채영현;이세연;박진선;홍세운
    • 한국농공학회논문집
    • /
    • 제64권5호
    • /
    • pp.27-39
    • /
    • 2022
  • The smart farm is recognized as a solution for future farmers having positive effects on the sustainability of the poultry industry. Intelligent microclimate control can be a key technology for broiler production which is extremely vulnerable to abnormal indoor air temperatures. Furthermore, better control of indoor microclimate can be achieved by accurate prediction of indoor air temperature. This study developed predictive models for internal air temperature in a mechanically-ventilated broiler house based on the data measured during three rearing periods, which were different in seasonal climate and ventilation operation. Three machine learning models and a mechanistic model based on thermal energy balance were used for the prediction. The results indicated that the all models gave good predictions for 1-minute future air temperature showing the coefficient of determination greater than 0.99 and the root-mean-square-error smaller than 0.306℃. However, for 1-hour future air temperature, only the mechanistic model showed good accuracy with the coefficient of determination of 0.934 and the root-mean-square-error of 0.841℃. Since the mechanistic model was based on the mathematical descriptions of the heat transfer processes that occurred in the broiler house, it showed better prediction performances compared to the black-box machine learning models. Therefore, it was proven to be useful for intelligent microclimate control which would be developed in future studies.

에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교 (Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units)

  • 신동호;우창규;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.