• Title/Summary/Keyword: Indoor Thermal & Air Environment

Search Result 242, Processing Time 0.024 seconds

The measured field survey for the improvement of the working environment of workers in the plant factory (식물공장 근로자의 작업 환경개선을 위한 현장실측 연구)

  • Kwo, Hyuk-Min;Jeong, Seok-Hwan;Kang, Joo-Won;Yang, Jeong-Hoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.43-52
    • /
    • 2014
  • A plant factory system is getting the spotlight as alternatives to cope with the weather anomaly and food crisis because of the global warming. A study on 'Plant Processing Factory System' has been proceeded to develope 'low-carbon green growth' since our government selected it as the green technologies in 2010. The plant factory has played a major role in growth industries connected to many other fields like low-carbon as well as lighting and automated system. This study is aimed to solve the problems on low productivity and health problem of plant workers caused by highly concentrated carbon dioxide and low temperature in each process in the plant factory. It is aimed to research data to understand the actual conditions of plant workers and improve the thermal environment.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Evaluation of Thermal Comfort during Sleeping in Summer - Part II : About mean Skin Temperatures and Physiological Signals - (여름철 수면시 온열쾌적감 평가 -제 2보 : 평균 피부온도 및 생리신호에 관하여 -)

  • Kim Dong-Gyu;Kum Jong-Soo;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • This study was performed to evaluate sleep efficiencies and conditions for comfortable sleep based on the analysis of EEGs and MST under four thermals conditions. Five female subjects who have similar life cycle and sleep patterns were participated for the sleep experiment. Their age was from 20 to 22 years old. They were healthy, and had regular sleep with consistent bed and wakeup time. It was checked whether they had a good sleep before the night of experiment. Experiments were performed in an environmental chamber of $4.1\times4.9\times2.7m$ size. EEGs were obtained from C3-A2 and C4-Al electrode sites. Sleep stages were classified, then TST, SWS latency and SWS/TST were calculated for the evaluation for sleep efficiencies on thermal conditions. As results, it was concluded that indoor thermal environments of $24\~26^{\circ}C$ was the best for comfortable and deep sleep.

Analysis on Characteristics of Indoor Environment and Satisfaction Level ofUsers of Senior Centers in Jeonju Residential Areas (전주시 단독주택 지역에 위치한 경로당의 실내 환경의 특성과 이용자 만족도에 대한 분석)

  • Jeoong, Insoo;Meng, Xiangwei
    • Journal of the Korean housing association
    • /
    • v.27 no.6
    • /
    • pp.31-43
    • /
    • 2016
  • The purpose of this paper is to gather information and opinions to better guide the direction for implementing improvements of the senior centers' indoor environments located in Jeonju residential areas, by surveying the users about the level of satisfaction and analyzing the result in relation to the current situation. Senior centers located in Jeonju residential areas were operating the facilities with low financial support from the local autonomous entity. According to the results of the survey, most of the users tend to use the facilities between 12p.m. to 6p.m., and the majority have lunch at the senior centers. Most of the senior centers already have cooking facilities, without a dining room, except one place, and even the facilities they have are very poor. In a thermal environment area, the temperature is mostly above in summer or below in winter the appropriate temperature, especially the temperature of the restroom of all senior centers are below $20^{\circ}C$ in winter. The density of carbon dioxide is above average in most indoor areas. However, the users' level of facilities' satisfaction was positive. To improve the seniors' quality of life, the local autonomous entity has to start regular check-ups and repair of the poor indoor environment and facilities, with more financial support and active supervision by senior center the management.

Physiological Responses of the Human Body on a Change of the Floor Temperature in Indoor (인공기후실내의 바닥온도 변화에 의한 인체의 생리적 반응)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.1
    • /
    • pp.21-30
    • /
    • 1998
  • The purpose of this study is to clarify the floor temperature on the human body and to estimate thermal comfort zone in a heated room. In order to evaluate the effects of floor heating, a series of experiments were carried out using Korean subjects. The following experiments were conducted: 1) to obtain the effective radiation area and configuration factors of the person in the sitting posture on a floor to get the mean radiant temperature, 2) to measure contacted area of the person to the floor to calculate conduction heat rate, 3) to measure convective heat transfer coefficient of the body and 4) to know the thermal comfort zone of indoor environment heated by ON-DOL. Subjects were exposed to the following conditions: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$, $25^{\circ}C$, and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $25^{\circ}C$, $27.5^{\circ}C$, $30^{\circ}C$, $32.5^{\circ}C$, $35^{\circ}C$, $37.5^{\circ}C$, $40^{\circ}C$ under still air and 50% relative humidity in the controllable artificial climate chamber. To evaluate the effect of heat conduction between the body and a floor modified mean skin temperature was defined. Weighting coefficient to calculate mean skin temperature were modified with the contacted area. The experiments revealed a positive correlation between the modified operative temperature and the modified mean skin temperature. The modified mean skin temperature can indicate the effect of heat conduction between body and a floor surface.

  • PDF

Subjective Responses to Thermal Stress for the Outdoor Performance of Smart Clothes

  • Kwon, JuYoun;Parsons, Ken
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.169-181
    • /
    • 2017
  • Objective: The aim of this study was to explore the influence of outdoor weather conditions on subjective responses during physical activity. Background: The largest difference between indoor and outdoor conditions is the existence of the sun. The heat load from the sun has an influence on the heat gain of the human body and the intense degree of solar radiation affected thermal comfort. Method: Thirty eight people were exposed to a range of climatic conditions in the UK. Weather in England does not have extremely hot and cold temperature, and the current study was conducted under warm (summer and autumn) and cool (spring and summer) climates. Measurements of the climate included air temperature, radiant temperature (including solar load), humidity and wind around the subjects. Subjective responses were taken and physiological measurements included internal body temperature, heart rate and sweat loss. Results: This study was conducted under four kinds of environmental conditions and the environmental measurement was performed in September, December, March, and June. The values for sensation, comfort, preference, and pleasantness about four conditions were from 'neutral' to 'warm', from 'not uncomfortable' to 'slightly comfortable', from 'slightly cooler' to 'slightly warmer', and from 'neither pleasant nor unpleasant' and 'slightly unpleasant', respectively. All subjective responses showed differences depending on air temperature and wind speed, and had correlations with air temperature and wind speed (p<0.05). However, subjective responses showed no differences depending on the radiant temperature. The combined effects of environmental parameters were showed on some subjective responses. The combined effects of air temperature and radiant temperature on thermal sensation and pleasantness were significant. The combined effects of metabolic rate with air temperature, wind speed and solar radiation respectively have influences on some subjective responses. In the case of the relationships among subjective responses, thermal sensation had significant correlations with all subjective responses. The largest relationship was shown between preference and thermal sensation but acceptance showed the lowest relationship with the other subjective responses. Conclusion: The ranges of air temperature, radiant temperature, wind speed and solar radiation were $6.7^{\circ}C$ to $24.7^{\circ}C$, $17.9^{\circ}C$ to $56.6^{\circ}C$, $0.84ms^{-1}$ to $2.4ms^{-1}$, and $123Wm^{-2}$ to $876Wm^{-2}$ respectively. Each of air temperature and wind speed had significant relationships with subjective responses. The combined effects of environmental parameters on subjective responses were shown. Each radiant temperature and solar radiation did not show any relationships with subjective responses but the combinations of each radiant temperature and solar radiation with other environmental parameters had influences on subjective responses. The combinations of metabolic rate with air temperature, wind speed and solar radiation respectively have influences on subjective responses although metabolic rate alone hardly made influences on them. There were also significant relationships among subjective responses, and pleasantness generally showed relatively high relationships with comfort, preference, acceptance and satisfaction. Application: Subjective responses might be utilized to predict thermal stress of human and the application products reflecting human subjective responses might apply to the different fields such as fashion technology, wearable devices, and environmental design considering human's response etc.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

Mobile Energy Shelter House(MeSH) for victims when a disaster occurs - Focused on Indoor Thermal Environmental Performance - (재난·재해 시 이재민을 위한 이동형 에너지 셜터하우스 (MeSH) 계획 -실내 온열환경 성능을 중심으로-)

  • Shin, Hwayeon;Kim, Jeonggook;Kim, Jonghun;Jeong, Hakgeun;Jang, Cheolyong;Hong, Wonhwa
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.75-80
    • /
    • 2014
  • Development of temporary housing for victims whose house damaged is required. In this study is to plan temporary house space 'Mobile Energy Shelter House ; MeSH' that can be inhabited for a long time. And measure the indoor Environmental performance. 'Mobile Energy Shelter House : MeSH' was made by reflecting Passive Design, Universal Design. Also, thermal insulation that meets the 'Korea standard insulation' for use low energy. Winter season, measuring temperature, humidity, air velocity and radiation temperature when floor heating that temperature controllers ware installed is used. Confirmed the data for the 8:00pm to 8:00am because evening hours are expected as residents live. Average outdoor temperature was $-11.3^{\circ}C$ and Indoor temperature was from $16.09^{\circ}C$ to $20.63^{\circ}C$. Calculated the TDRi of the window surface for checked condensation risk. TDRi value was 0.185. Furthermore, PMV value was -0.08 to -0.85. It was satisfied to ISO comfort criterion ranged.

Operation Performance Evaluation on Auxiliary Heating Device to Prevent Condensation adjacent to Built-in Furniture of Apartment Units in Winter (기존 공동주택 붙박이장에서 겨울철 결로 방지를 위한 보조난방장치 운전 성능 평가)

  • Lee, Chae-Lyn;Lee, Hyun-Hwa;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.567-578
    • /
    • 2018
  • The purpose of this study was to evaluate condensation prevention for condensation vulnerable areas around built-in furniture of apartment buildings by applying auxiliary heating device. Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, auxiliary heating device was developed and could be installed. The aim of paper is to analyze the thermal environment around the built-in furniture which were applied and not applied auxiliary heating device in winter. In results, it was possible to increase the surface temperature of vulnerable areas around built-in furniture by applying auxiliary heating device, and to minimize condensation problems by using the minimum device.

A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser (급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.