• 제목/요약/키워드: Indoor Thermal & Air Environment

검색결과 242건 처리시간 0.028초

옥상녹화시스템의 식재방식에 따른 단열효과의 정량적 분석 (Quantitative Analysis on the Insulating Effect by the Green Roof Planting System)

  • 장희경;조홍제;여인애;윤성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.873-876
    • /
    • 2008
  • The purpose of this study was to investigate Green Roof System's thermal performance using dynamic heat load simulation programs related to architectural environment. In results, it is found out that the thermal performance of Green Roof System is stabler than that of roof slab system which means that it is possible to create pleasant indoor environment and save the heating and cooling load.

  • PDF

온돌 온열환경지표 평가방법 (Evaluation Methods on ONDOL Thermal Environmental Index)

  • 김성조
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.101-110
    • /
    • 2022
  • For this purpose, the authors proposed and proved usefulness of the modified mean skin temperature which is integrated mean radiation temperature and the effect of floor contacted heat conduction. The mean radiation temperature is applied form factor between half cross-legged human body and surrounding wall of indoor. In addition the floor contacted heat conduction is applied heat transfer coefficient of half cross-legged human body. Eight Korean young men were targeted for the experiment. From the experiment the authors excerpted physiological reaction and psychological reaction in Ondol environment which is combined physiccal environmental factor of artificial climate chamber, air and floor temperature. As a result of the experiment it is confirmed that heat conduction has more impact than heat exchange from existing research for the heat exchange between half cross-legged human body and surrounding wall in Ondol thermal environment. Thereby, it is proved the effectiveness of the modified mean skin temperature which is added floor contacted temperature to the Ondol thermal environmental evaluation index.

노후 학교건물의 창호 교체에 따른 부하분석 (Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building)

  • 이예지;김주욱;송두삼
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.

동계에 차양 적용에 의한 실내 환경 측면의 효과에 관한 실험적 연구 (An Experimental Study on the Effect on Indoor Environment by the Application of the Shading Device in Winter)

  • 백주영;김지현;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.854-859
    • /
    • 2006
  • This study aims to evaluate the effect on indoor environment by the application of the shading device on winter season. Therefore, thermal and visual experiments were conducted at two side-by-side mock-Lip test cells which were equipped with the shading device(venetian blind & roll blind) at interior and exterior side of the window. The results of this study are as follows: 1) At night of winter, the shading device can prevent internal heat from going out. 2) Exterior shading device is more effective in winter as well as in summer. 3) At daytime of winter, the shading device can provide the uniformity of illuminance, and the interior shading device is more effective.

  • PDF

아트리움의 수직온도 분포해석 프로그램의 개발에 관한 연구 (A study on the Development of Vertical Air Temperature Distribution Model in Atrium)

  • 김용인;조균형;김광우
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.3-11
    • /
    • 1997
  • Recently the construction of atrium buildings has increased but along with it many problems in thermal environment have arised. since the exterior wall of glass, indoor temperature is greatly influenced by weather conditions and since the space volume is very large, the vertical air temperature is not uniform. So, in this study, a Vertical Temperature Distribution Model was developed to predict the vertical air temperature of an atrium and evaluate the effects of the design parameters on the air temperature distribution of an atrium. To consider the characteristics of the vertical air temperature distribution in an atrium, the Satosh Togari's Macroscopic Model was used basically for the calculation of the vertical air temperature distribution in large space and the solar radiation analysis model and natural ventilation analysis model in atrium. And to calculate the unsteady-state inside wall surface temperature(boundary condition), the finite difference method was used. For the verification of the developed temperature distribution program, numerical evaluation of air flow by the ${\kappa}-{\varepsilon}$ turbulence model and in-situ test was conducted in parallel. The results of this study, the developed temperature distribution program was seen to predict the thermal condition of the atrium very accurately.

  • PDF

웹 및 건물정보모델기반 실내 환경 디지털 시각화 -온습도와 미세먼지 농도 데이터를 중심으로- (Web and Building Information Model-based Visualization of Indoor Environment -Focusing on the Data of Temperature, Humidity and Dust Density-)

  • 황금화;이진국;전규엽
    • 한국콘텐츠학회논문지
    • /
    • 제17권2호
    • /
    • pp.327-336
    • /
    • 2017
  • 최근 실외 및 실내 공기의 질에 대한 사람들의 관심이 증가하면서 다양한 관련기기들이 사용되고 있다. 실내 환경의 여러 요소 중 특히 사람들의 쾌적감에 직접 영향을 주는 온열 환경과 눈에 보이지 않는 실내 공기 환경의 시각화는 그러한 이유로 매우 중요하게 부각되고 있다. 본 연구는 거주자가 공기 질 등과 같은 실내 환경 상태를 기존의 숫자나 그래프 등 보다 쉽고 직관적으로 파악하는 것을 지원하기 위하여 기존의 실내 환경 시각화 사례들을 분석하고 이를 보완하기 위한 개선방법을 모색하여 보다 효과적인 웹 및 건물정보모델기반 시각화 방법을 제안하고자 한다. 본 연구에서 제시하는 해당 실내 환경 시각화 과정은 크게 네부분으로 구성된다. 이는 건물 모델 데이터 생성, 실내 환경 데이터 생성, 시각화 표현 요소 생성, 데이터 매핑 및 시각화 결과 생성 과정으로 요약될 수 있다. 생성된 시각화 결과는 다양한 실내 환경 요소의 동시 파악을 지원할 뿐만 아니라, 대상 공간의 기하학적 모델과 측정된 실내 환경 데이터를 연계하여 시각화함으로써 실내 환경 상태의 파악이 직관적이며 즉각적이다. 본 논문은 IoT 등의 기술로 즉각적이고 자동화된 실내 환경 관리시스템의 개발방향과는 별개로, 실내 환경 데이터를 적절히 가공함으로써 사용자 및 관리자 등에게 관련 시각정보를 효율적으로 제공하는 접근방법을 모색하는 것을 목적으로 한다.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향 (The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House)

  • 김현태;송준익;최홍림
    • 한국축산시설환경학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2012
  • 돈사의 피상부(皮上部) 환경개선을 위한 본 연구에서는 경기도 용인군에 위치한 형제농장의 비육돈사를 실험축사로 선정하여, 외부환경에 따른 돈사환경의 변화, 실내 공기유동을 위한 팬의 유무 등이 실내환경에 미치는 영향을 살펴보았다. 그 결과 다음과 같은 결론을 얻을 수 있었다. 1. 외기온이 $25.7^{\circ}C$인 실험 1의 경우 측벽 윈치커튼을 통하여 유입된 공기는 용마루(ridge)의 윈치커튼를 통하여 배출되었으며, 중앙단연의 속도가 바닥부근 유속의 2~3 배에 이르는 것은 열부력(thermal buoyancy) 때문에 공기유동이 에너지를 얻어 유속이 가속되었으며, 측벽 윈칙커튼으로 유입된 공기유동은 급격히 확산되어 소산(消散)(disssipation)되었다. 그러므로 윈치커튼 돈사의 경우, 외부 바람의 속도가 거의 없거나 있어도 속도가 적다면, 돈사내 공기유동의 형태는 주로 열부력에 의하여 결정됨을 알 수 있다. 2. 실험 1에서는 비교적 균일한 온도분포를 보이고 있으나 실내온도가 외부에 비하여 전반적으로 외기온 보다 높게 나타났으며, 이는 돼지의 현열 및 배출분뇨에 의한 바닥층의 부숙열이 피상부(皮上部) 공간의 현열접적을 환기로 적절히 제거시키지 못한 결과로 판단된다. 따라서 실내에서 발생되는 열을 효과적으로 제거하기 위하여서는 강제환기 시설 또는 측벽 및 용마루 윈치커튼의 개폐정도 등을 포함한 관리논리를 개발할 필요하다. 3. 실험 2는 실험 1과 같이 외기온이 $25.7^{\circ}C$로 비슷하나 복사열의 영향여부를 실험 1과 비교검정하기 위하여 흐린 날을 선택하고 돈사내 강제환기를 위한 팬을 작동시킨 상태에서 중앙단면에서의 유속을 측정한 결과 실험 1에 비해 속도가 대체로 크나, 편차 또한 크게 나타났으며, 팬 작동시 공기유동의 정체지역(dead region)이 발생한 것을 알 수 있었다. 따라서 강제환기시에는 보다 정확한 환기율을 결정하고 설계 시공이 필요할 것으로 판단된다. 또한 바람이 없고 외기온이 매우 높은 여름철에는 열집적을 효과적으로 희석시키기 위해서 연속적인 강제환기가 필요할 것으로 판단된다. 4. 실험 2에서의 유해기체의 농도를 실험 1과 비교해 보면 전체적으로는 편차가 적게 나타났으며, 외부기상의 차이로 인해 암모니아의 농도는 실험 1에 비해서 매우 높게 나타났다. 이는 외부기상에 따른 실내공기 유동의 효율저하, 상대습도의 변화 등으로 판단되며, 외기상의 변화에 능동적으로 대처할 수 있는 환기시스템의 개발도 고려해볼 필요가 있다. 5. 실험 2에서의 온도분포는 거의 편차가 없이 균일하게 나타난 것을 볼 수 있었으며, 비로 인하여 지붕이 받는 부가적인 태양복사열이 없었으며, 실험 1과는 달리 열부력에 의한 상고하저(上高下低)의 전형적인 수직분포가 나타나지 않고, 오히려 지붕을 냉각시키는 효과를 가져와 상저하고(上低下高)의 분포를 나타냈으며, 수평온도분포도 팬에 의한 강제환기에 의해 실내공기를 균일하게 분포시켜 거의 편차가 없음을 알 수 있었다. 그러므로 지붕의 단열이 축사환경제어에 중요한 변수로 작용한다는 것을 알았으며, 이를 위해서 지붕의 단열 및 높이 등의 설계가 매우 중요하다.

플라즈마 공정에 의한 Styrene 처리에 관한 성능 평가 및 부산물 동정 연구 (A Study on the Performance Evaluation and by-product of styrene decomposition by Non-thermal Plasma Processing)

  • 박정욱;전보경;최금찬
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.69-70
    • /
    • 2003
  • 최근 실내공기 질(IAQ : Indoor Air Quality)에 관한 인식이 높아지고 있으며 환경개선에 상응하는 기술 개발의 중요성이 크게 부각되고 있다. 실제 산업체에서는 여러 가스정화기술들이 오염물질제거에 이용되어 왔고, 그 한 분야인 N.T.P(Non-thermal plasma Process) 공정도 다양한 각도에서 연구가 수행되어 왔다. 그러나, 이 기술의 실용화를 위한 설계변수 개념의 연구는 부족한 실정으로, 이에 본 연구는N.T.P 공정에 의한 가스정화의 반 경험식 도출과 이를 이용한 성능 평가 고찰이 주목적이다. 또한, 반응기 통과 후 나오는 부산물을 동정하여, 차후 후단에 사용할 촉매를 결정 하고자 한다. (중략)

  • PDF

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.