충남지역 미적용 다중이용시설의 실내공기질에 관한 연구 (A Study of Indoor Air Quality of Public Facilities in Chung-Nam Area)

  • 홍성철;조혜미;조태진;이치원;정용택;손부순
    • 환경위생공학
    • /
    • 제23권2호
    • /
    • pp.35-45
    • /
    • 2008
  • In order to recommend criteria for the administration law on indoor air quality, this study was conducted to examine the distribution and the concentration of indoor air pollutants ($PM_{10},\;CO_2$, CO, HCHO, TBC, $NO_2$, Rn, VOCs, asbestos, $O_3$) in public facilities in the Chung-Nam area. The concentrations of indoor air pollutants were obtained from sixty seven public facilities such as a cinema, an office, a restaurant, a theater and an academy. This study was performed from August to December, 2005. The results of this study showed that the concentrations of indoor air pollutants such as $PM_{10},\;CO_2$, CO, HCHO, TBC, Rn and $O_3$ were less than the recommended limits. However, the average concentration of VOCs was $521.73{\mu}g/m^3$ (GM : $221.69{\mu}g/m^3$), which was higher than the recommended limit of $400{\mu}g/m^3$. Moreover, the average concentration of $NO_2$ was 345.66ppb (GM : 69.95ppb), which was higher than the recommended limit of 50 ppb. The correlation between the concentrations of indoor air pollutants and the type of facilities with respect to $CO_2$, TBC and Rn was statistically low (p<0.05). However, the correlation was high in terms of the CO and $O_3$ concentrations (p<0.01). No relationship between the indoor air pollutants and the type of facilities was observed for $PM_{10}$, VOCs and $NO_2$. The year of construction was compared to the concentrations of indoor air pollutants. Specifically, when the construction date was less than 3 years, the HCHO, VOCs and TBC concentrations were $44.75{\mu}g/m^3,\;555.07{\mu}g/m^3$ and $337.79CFU/m^3$, respectively. These concentrations were $120{\mu}g/m^3$ and $211.84CFU/m^3$ higher for VOCs and TBC than the concentrations obtained from the facilities more than 3 years. However, the concentration of HCHO was similar between the facilities older and younger than 3 years of age. Year, temperature, humidity and indoor air pollutant correlation analyses showed that temperature and humidity, temperature and TBC, temperature and $O_3,\;PM_{10}$ and $NO_2$, HCHO and VOCs, $CO_2$ and Rn had positive relationships. However temperature and Rn, humidity and $CO_2,\;CO_2$ and $O_3,\;O_3$ and Rn had negative relationships. Accordingly, it will be necessary to manage the factors affecting indoor air quality so that the residents can have a more comfortable and healthier living environment. Ultimately, the results of this study are expected to be utilized as baseline data.

영유아 교육시설에서의 실내공기질 평가 (The Evaluation of Air Quality in Educational Child Care Centers)

  • 임지혜;방승기;손장열
    • 교육녹색환경연구
    • /
    • 제9권1호
    • /
    • pp.1-10
    • /
    • 2010
  • It is indispensable for child care centers to investigate and manage indoor air quality (IAQ) because they perform education and day care for children who usually have weak immunity. Nevertheless, there is insufficient research being done, given its importance. This study aims to investigate indoor pollutants' concentration and to seek the causes in order to improve the air quality conditions. Also it aims to secure data which can be used for further researches. Measurements were performed for air temperature, relative humidity, carbon dioxide, carbon monoxide, fine particle mass, formaldehyde and volatile organic compounds. Temperature, humidity, CO and CO2 were measured 30times(1min/time) and PM10 was measured 10times (3min/time). Formaldehyde and volatile organic compounds were measured and analyzed based on The Indoor Air Quality Official Test Method. The results show that the temperatures were within the comfort zone in over half of the centers. CO2 was found to be the main pollutants as its concentration exceeded the IAQ standard. The concentrations of TVOC and PM10 exceeded the standard, by 32% and 24% respectively, whereas those of HCHO and CO were under the standard. HCHO and CO concentrations were under the guideline. 24% of child care centers for education were found to exceed the standard in 2 or more of the pollutants. 82% of were found to exceed the standard by 1 or more. Therefor it is requested for IAQ to manage and improve in child care center for education.

출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석 (Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin)

  • 권순박;조영민;박덕신;박은영
    • 한국대기환경학회지
    • /
    • 제24권2호
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

서울시 도로변의 $PM3.5/NO_2$ 농도비 및 구두수선대 근로자의 노출평가 ($PM3.5/NO_2$ Concentration Ratio in Roadside and Exposure Assessment of Shoes Repairmen in Seoul)

  • 배현주;양원호;김나리;정문호
    • 환경위생공학
    • /
    • 제16권4호
    • /
    • pp.21-30
    • /
    • 2001
  • Vehicles, especially diesel-using, are a major source of airborne particulate matter(PM), nitrogen dioxide($NO_2$) and so on in metropolitan cities such as Seoul. Therefore workers, who are mainly merchants, near roadside may be highly exposed to air pollutants from exhausted emissions of vehicles. This means that occupational type and location can affect the workers'health by exposure to outdoor pollutions of ambient as well as indoor pollutions of working condition, respectively. In this study, we simultaneously measured the PM3.5 and $NO_2$concentrations in indoor and outdoor of shoes repair shops in Seoul, which were generally located at roadside in Korea. Shoes repairmen were highly exposed to PM3.5 and $NO_2$ both indoor and outdoor of repair shops comparing with other sub-population groups. High exposure to air pollutants for shoes repairmen was considered to be outdoor source from exhausted emission of vehicles and indoor source from working condition. The $PM3.5/NO_2$ concentration ratio was $1.17{\pm}$0.59 in roadside, of which ratio was higher 7han ratios of other studies. This result suggested that major air pollutant in Seoul was fine particle. Also, this PM3.5 to $NO_2$ ratio will be used in environmental exposure and risk assessment by estimation of PM3.5 concentration as measuring the only $NO_2$ concentration with small and accurate $NO_2$ passive sampler.

  • PDF

호남지역의 다중이용시설별 실내공기질 실태 조사 (Indoor Air Quality in Various Type of Public Facilities at Honam Province)

  • 서병량;정만호;전준민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

광촉매와 조합된 코로나 방전 플라즈마 필터의 유해 가스 및 입자 제거 특성 (A Compact Pulse Corona Plasma System with Photocatalyst for an Air Conditioner)

  • 신수연;문재덕
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.151-155
    • /
    • 2007
  • A compact discharge plasma system with a photocatalyst has been proposed and investigated experimentally for application to air conditioners. It was found that there was intense ultra violet radiation with high energy of 3.2 eV from the corona discharge due to the DC-biased pulse voltage applied on a wire. An electrophotochemical reaction took place apparently on the surfaces of the photocatalyst of $TiO_2$ irradiated ultra violet front the discharge plasma in the proposed plasma system. The proposed discharge plasma system with the photocatalyst of $TiO_2$ showed very high removal efficiency of VOCs by tile additional electrophotochemical reactions on the photocatalyst. The proposed discharge plasma system also showed very high removal efficiency of particles such as smokes, suspended bacteria, and pollen and mite allergens by the electrostatic precipitation part. This type of corona discharge plasma system with a photocatalyst can be used as an effective means of removing both indoor pollutant gases and particles including suspended allergens.

신축 아파트의 실내 마감재 변경 및 시공단계별 휘발성유기화합물 발생 특성 (Characteristics of VOCs Emission According Interior Finish Materials and Working Phases of New Apartments)

  • 방승기;조우진;손장열
    • 설비공학논문집
    • /
    • 제18권6호
    • /
    • pp.486-492
    • /
    • 2006
  • In this research, IAQ is measured to evaluate the emission performance of VOCs in three new apartment houses finished by totally EFMs (Environmental Friendly Material), partially installed EFMs and general materials. Among various VOCs, Target pollutants for the IAQ measurement are benzene, ethylbenzene, toluene, xylene, 1,4-Dichlorobenzene and formaldehyde. The measurement is conducted one day after each interior finishing material is worked over by construction schedule. The result of this research concluded that (1) Except toluene, the concentration levels of each pollutant did not exceed the national IAQ standards in all test residences, (2) As the interior finishing work schedule, A toluene level peaked when the furniture installing was ended. (3) The toluene concentration level of the house installed general interior materials as the non-EFMs furniture was one and half higher than other houses. Consequently, installing. the furniture made by EFMs is one of effective methods to improve the IAQ for new apartment houses.

TiO2를 치환율에 따른 투수블록의 흡착 특성 (Adsorption Properties of Permeable Block according to the Replacement Ratio of TiO2)

  • 이혜은;유재균;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.74-75
    • /
    • 2021
  • In the recent 2017 annual average fine dust concentration (PM2.5) statistics released by the Organization for Economic Cooperation and Development (OECD), Korea has a high concentration of 25.14㎍/m3, which is about twice the average of 12.5㎍/m3 in OECD countries. Fine dust (PM2.5) is the main source of secondary pollutant production by the reaction of primary pollutants emitted from automobiles and thermal power plants, mainly composed of sulfates, nitrates, and organic carbon. The permeable block is an eco-friendly product that prevents rainwater from collecting on the surface of the road because it does not penetrate the groundwater properly, and is widely constructed on sidewalks or parking lots to recharge groundwater in case of rain. In addition, the pavement of the permeable block is a fundamental solution to reduce pollution by preventing rainwater from flowing into the stream, and it also has the advantage of easy replacement as well as low replacement costs. Therefore, this study was a basic experiment to produce permeable blocks mixed with TiO2 and diatomite to improve indoor air quality, and intended to analyze the flexural strength and compressive strength of permeable blocks mixed with TiO2.

  • PDF

에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 (Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사 (The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation)

  • 전정인;이혜원;최현진;전형진;이철민
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.