• Title/Summary/Keyword: Indoor Pollutant

Search Result 141, Processing Time 0.023 seconds

Heat Insulation Properties of Lightweight Magnesia Matrix According to Mixing Ratio of Anthracite (안트라사이트 치환율에 따른 경소마그네시아 경화체의 단열특성)

  • Pyeon, Su-jeong;Gwon, Oh-han;Kyoung, In-soo;Lee, Dong-hoon;Lee, Sang-soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.113-114
    • /
    • 2017
  • Recently, Subway workers have died from lung cancer. According to the Epidemiological Survey of the Welfare Corporation Institute of Pulmonary Disease of the Welfare Corporation, the family members applied for industrial accidents. The radon concentration in the subway work area was found to exceed 10 times the recommended standard value of 148 becquerels (Bq/㎥) in domestic multipurpose facilities. In addition, as a result of the national indoor radon concentration survey conducted by the Ministry of Environment in 2010 and 2013, housing was found to be over 100 becquerels (Bq/㎥) in 41% of the surveyed subjects. In addition, it was found that in 2012, 16.3% of villages exceeded the radon standard value in the survey on natural radioactive materials containing groundwater.

  • PDF

A Study on the Emission Characteristics of Gaseous Organic Contaminants from Building Materials and Newly Constructed Apartments (신축 공동주택 및 건축자재에서의 오염물질 방출 특성)

  • Kim Yun-Deok;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.563-570
    • /
    • 2006
  • We investigated the emission characteristics of gaseous organic contaminants from building materials and newly constructed apartments. The emission test for building materials was done with small chamber method, and field measurements in newly constructed apartment were carried out by Korea Standard Test Method for Indoor Air Quality. First, the emission test by small chamber showed that the TVOC emission from building materials was much higher than formaldehyde. On the other hand, as expected, considerably high concentration of both TVOC and HCHO was detected in the new apartment.

An Exploratory Research on Social Workers' Attitude and Related Factors about Indoor Air Quality Management of Social Welfare Facilities (사회복지시설 종사자의 실내공기질 관리에 대한 태도와 관련 요인에 관한 탐색적 연구)

  • Bae, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.5
    • /
    • pp.273-284
    • /
    • 2017
  • As these days people spend most of time at inner space, indoor air quality affect human life seriously. Government manage indoor air quality of various facilities based on different laws. Government released that they would try to protect environment for vulnerable people such children and seniors from indoor air pollutants in 2015. But social welfare facilities are exception under current legal systems. Clients of social welfare residential facilities are the disables, the elderly, homeless and children and they usually stay inner space very long time. The purpose of this study is explore workers' attitude and related factors about indoor air quality management of social welfare facilities. 69.5% of respondents agree to government's indoor air quality management, 80.9% of respondents think social welfare facilities must be included in legal system for indoor air quality management. Environmental awareness and law awareness were related with attitude to indoor air quality management. Based on the results of the analysis, I propose the amendment of law on indoor air quality of the Ministry of Environment, cost burden of central or local government and the necessity of education and research on indoor air quality management in social welfare facilities.

A Study of Development of Evaluation on Source Strength and Deposition Constant of VOCs (주택 실내환경 VOCs의 발생량 및 감소량에 관한 연구)

  • Jung, Soon-Won;Yang, Won-Ho;Kim, Dae-Sun;Song, Mi-Ra;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1019-1026
    • /
    • 2007
  • This study was performed in 30 selected apartments in Seoul, Asan and Daegu area which were constructed within 4 years and over 4 years, to measure the concentration of VOCs(benzene, toluene, xylene) from July, 2004 to September. Mean ratios of indoor to outdoor VOCs concentrations in the construction under 4 years were higher in 1 than average, I/O ratio of over 4 years were lower in 1. This was considered that the VOCs density influences indoor pollutant. For the indoor air quality estimation, the deposition constant and the source strength factor of toluene were $1.49{\pm}2.05\;hr^{-1}\;and\;36.95{\pm}52.26\;ppb/h$, respectively.

Analysis of Natural Ventilation Effect of Seoul Metropolitan Subway by Monitoring Indoor $CO_2$ Concentrations (수도권 전동차 객실 $CO_2$농도관측을 통한 자연환기효과 해석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.965-968
    • /
    • 2007
  • Two major parameters, i.e. carbon dioxide ($CO_2$) and particulate matters smaller than $10{\mu}m\;(PM_{10})$, were selected as the index pollutants in managing indoor air quality. The former pollutant, $CO_2$, is the index that shows the ventilation status and is exhaled by passengers when they breathe in train or subway. It is generally known that high $CO_2$ concentration in the vehicle may be decreased by insufficient air-tightening vehicle bodies and the air is ventilated when vehicles stop at the station and doors open. However, there is no established proof or quantitatively identified data on how much the $CO_2$ concentration is reduced when ventilation is done while doors are opened. In this study, $CO_2$ concentrations were measured in 6 lines of Korail and one line of Seoul Metro subway linesand a theoretical approach was takento predict the changing trend of $CO_2$ concentrations during the operation of vehicle by using $CO_2$ dilution factor through natural ventilation. As a result, the change could be quantified and it was found that app. 35% of indoor $CO_2$ was removed through natural ventilation.

  • PDF

An Investigation of Citizen's Attitude on the Harmful Insects in House (주택에서의 유해생물에 대한 시민 인식도 조사)

  • 김영환;손종렬;문경환;변상훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.36-40
    • /
    • 2002
  • The purpose of study was to suggest an investigation of citizen's attitude on harmful insects in house. This study was consisted of four parts, such as basic investigation (housing shape, housing material, the period of house constructed, a cleaning condition), condition of kitchen, condition of living room condition of bathroom. The environmental pollution was increased by the development of industry and urbanization in modern. And also the clean of house has related with air quality such as pollutants and harmful insects etc. Because dwelling shape of urban come to be crowded, shut tightly and high buildings, the air quality of indoor was gradually polluted by several irregular cause. In one of housing pollution, the harmful insects was important any other than indoor air pollution. The problems of kitchen were the odor of food waste, discharge system of sewage and harmful insects. The important issues of living room were mold and construction materials, then important them of bathroom were easing nature and discharge system of sewage. A kind of the harmful insects in house investigated cockroach> mosquito> ant>fly. Finally, it appeared that the control of harmful insects can be applied to the improvement of indoor air pollutant which are difficult to be controlled in house.

Consideration of Ozone Removal and Control in Built Environment by Building Materials (건축자재에 의한 실내 오존제거 및 제어에 대한 고찰)

  • Chung, Ok-Young;Jeong, Su-Gwang;Kim, Jun-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.467-475
    • /
    • 2012
  • Recently, residents have been spending almost 90% of their time indoors, which presents a higher risk from inhalation of pollutants than when spending time outdoors. Therefore, controlling indoor air quality became important. It is reported that the lung diseases and mortality for occupants are increased when there is high density of ozone which is one of the pollutants among the indoor air. In addition, the reactions between ozone and building materials produce VOCs and formaldehyde. The studies to eliminate the ozone by building materials have been actively investigated. However, ozone removal and secondary pollutants from ozone reactions with building materials have not been reported in Korea. For this reason, the aim of this study is to introduce ozone removal by HVAC filters, various building materials, and eco-friendly building materials including the quantity of secondary pollutant emissions.

Properties of Cement Matrix According to Carbonized Sludge Replacement Ratio (탄화슬러지 치환율에 따른 시멘트 경화체의 특성)

  • Park, Chae-Wool;Kim, Yeon-Ho;Choi, Byung-Cheol;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.143-144
    • /
    • 2020
  • For modern people who spend 80% of the day indoors, indoor air quality is an important factor in their lives. Radon and fine dust, which are indoor air quality pollutants, cause various diseases and lung diseases, so a method is needed to reduce them. Therefore, this study intends to utilize the air pollutant adsorption properties of the carbonized sludge by using the carbonized sludge generated through drying and carbonization of the sludge. As a result of the experiment, it was shown that the concentration of radon and fine dust gradually decreased as the replacement ratio of carbonized sludge increased. The reason is that the carbonized sludge has the ability to adsorb fine dust and radon, so it is considered that it gradually decreases as the replacement ratio increases. Also, the compressive strength and flexural strength tend to decrease gradually. The reason for this is that the carbonized sludge has a number of internal voids, and as the replacement ratio increases, the internal voids increase and the strength decreases. If the refinement and strength of the carbonized sludge replacement ratio are supplemented, it is believed that it will be able to replace the existing finishing materials.

  • PDF

Fine Dust Adsorption of Cement Matrix Using Sepiolite (세피올라이트를 활용한 시멘트 경화체의 미세먼지 흡착 특성 )

  • Jeon, Eun-Yeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.71-72
    • /
    • 2023
  • As industrialization and urbanization accelerate, environmental issues have moved from local concerns to global issues. Among them, air pollution is the most important issue. Modern people spend more than 88% of their day indoors, but the concentration of fine dust and pollutants flowing indoors is increasing. The indoor environment has its own complexity, and various substances used indoors, such as building materials, furniture, electronics, and cleaning agents, emit chemical substances and cause various diseases. Therefore, when selecting building materials and interior finishing materials, the pollutant emission and adsorption capacity must be greatly considered. These considerations will ensure the construction of a sustainable future environment and a healthy life within that environment. Therefore, in order to reduce the generation of indoor air pollutants, this study aims to examine the fine dust adsorption properties of cement hardening materials using sepiolite, which has a porous structure and high absorption power among clay minerals. As a result of the experiment, it was found that the concentration of fine dust decreased as the addition rate of sepiolite increased. It is believed that the fine dust concentration was reduced due to the high porosity due to the microfibrous structure and large specific surface area of sepiolite, which has a porous structure among clay minerals. It is believed that these experimental results can be used as basic research for future use of sepiolite as a construction material.

  • PDF