• 제목/요약/키워드: Indoor Noise

검색결과 429건 처리시간 0.023초

실험실 공기질 개선을 위한 라인디퓨져의 특성 평가 (Characteristic Evaluation of Line Diffusers for Air Quality Improvement of Laboratory)

  • 조수현;이철구
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.14-22
    • /
    • 2008
  • This study is aimed at suggesting a linear-type diffuser which is excellent in terms of range and elegance like existing diffusers in which amount and direction of wind can be freely controled, out of linear-type diffusers with the highest possibility to be adopted for living space of apartments whose height between floors is not so high and utilizing the linear-type diffuser in design. For the purpose, I examined necessary flow and noise properties of linear-type diffusers. Besides, I evaluated its ventilation capacity for persons in there by applying this in the actual living space. I evaluated features and air blast and found that in time of horizontal and vertical effusion, its T/L ratio is 1-1.5, similar to existing cardioid-type linear diffusers, while in time of slope effusion, it is similar to horizontal effusion in terms of range and it has medium figure in terms of pressure drop and effusion speed, indicating it can provide safe and pleasant indoor environment for persons in there in terms of ventilation.

전통주택의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses)

  • 김선우;이태강;김형렬;김항;최은석
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

음장제어용 막재료의 음향 및 단열특성 (Sound Absorption and Thermal Insulation Characteristics of Membrane Used for Sound Field Control)

  • 정정호;김정욱;정재군;조병욱
    • 한국소음진동공학회논문집
    • /
    • 제22권2호
    • /
    • pp.103-114
    • /
    • 2012
  • Nowadays membrane material is widely used for large indoor spaces and long spaces such as traditional market. Thermal insulation and sound field control performance is considered as a main properties for design of such buildings. In this paper sound absorption and thermal insulation properties of membrane material was investigated. Firstly, normal incidence sound absorption coefficient of 10 kinds of glass wool textiles showed that sound absorption coefficient was increased in proportion of thickness and surface density of textile. Sound absorption coefficient of 4 kinds of sound absorptive inner membrane with outer membrane was tested in the reverberation chamber. Sound absorption coefficient of mid frequency range was about 0.4 ~ 0.6. Also, sound absorption coefficient was changed by the air space behind the membrane material. Secondly, sound field control performance was investigated using mock-up space. By the installation of sound absorption membrane material, reverberation time was decreased and speech intelligibility was increased. Finally, thermal resistance and room temperature in two kinds of mock-up rooms were tested, simultaneously. Results of thermal properties showed thermal insulation properties ware increased by adding inner membrane material underneath the outer membrane.

외부광잡음에 의한 실내외 가시광 무선통신 성능 변화 분석 (Performance Analysis of Indoor/Outdoor Visible Light Communication System Influenced by External Noise Light)

  • 양세훈;김덕래;김현승;손용환;한상국
    • 한국통신학회논문지
    • /
    • 제36권12B호
    • /
    • pp.1595-1600
    • /
    • 2011
  • IM/DD 방식을 이용한 가시광 무선 통신의 성능 저하를 발생시키는 인공광과 태양광에 의한 잡음 레벨을 분석하였다. 통신 성능을 확인하기 위해 LED에 QPSK로 변조된 50ksymbol/sec의 신호를 2MHz의 부반송파에 전송하였으며 PD를 통해 수신된 신호의 EVM과 스펙트럼을 분석하였다. 또한 차광막을 이용하여 신호의 성능을 향상시켰으며 이를 통해 IM/DD방식으로 실외 가시광 통신이 가능함을 확인하였다.

음향측정시 실의 종류와 음원에 따르는 음향인자 측정분석에 관한 연구 (A Study on the Acoustical Characteristics of Pistol Impluse and MLS Source Measurements in Room Types)

  • 김정중;손장렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1028-1031
    • /
    • 2004
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, to how exactly through space sound source that wish to deliver from indoor can be passed does quantification sound estimation method is proposing various kinds physical parameter to estimate degree of voice definition (Speech articulation) and reverberation. Result that evaluate sound source about MLS signal and Impluse signal by pistol in this treatise could know that converge in MLS and measurement error extent about reverberation time(RT) of sound benevolent person. And value is thought there is problem showing change irregularly about sound benevolent person of D50, C80 etc. Finally, in case is spread sound field in difference of sound pressure level, when measure about change of sound pressure level, sound benevolent person could know that there is no different effect.

  • PDF

저속 회전 시 배기시스템의 배압이 정숙성에 미치는 영향 (Influence of Back Pressure of an Exhaust System on Quietness at Low-Speed Rotation)

  • 강일석;양성모
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.69-75
    • /
    • 2019
  • In recent years, the driving performance and exhaust sound quality in automobiles have been recognized as important factors, as they maximize the driving fun to fulfil the demands of customers. Therefore, many automobile manufacturers are studying various exhaust pipe shapes to improve sound quality and optimize exhaust pressure. The objective of the exhaust pipe design is to maximize the engine efficiency using optimal exhaust pressure settings. In this study, an exhaust system was fabricated with different junction shapes, and the results were analyzed through various experiments. The exhaust gas pressure acting inside the exhaust pipe was measured using a pressure transducer. Meanwhile, the vibration generated in the vehicle was measured in three axial directions and analyzed. The ground noise generated in the indoor and outdoor of the vehicle was measured, and the noise generated at the maximum output was measured and analyzed.

댐 수차 발전기 소음의 전달특성과 평가에 관한 연구 (A Study on Traveling Characteristics and Evaluation about Noise of Hydraulic Turbine Dynamo in Dam)

  • 윤재현;국정훈;김재수
    • 대한환경공학회지
    • /
    • 제30권7호
    • /
    • pp.705-711
    • /
    • 2008
  • 국내의 경우 1965년 섬진강댐을 시초로 홍수조절 수력발전 관개 상수 공업용수 공급 등의 역할을 하는 14개의 다목적댐을 건설하였다. 이러한 다목적댐의 경우 물의 낙차와 양에 의한 위치에너지를 운동에너지로 전환하여 전기에너지를 생산하게 된다. 그러나 이 과정에서 수차 발전기에 연결된 터빈의 회전시 고소음을 발생시켜 사람들에게 신체적, 정신적 악영향과 효율적인 업무능률의 저하를 초래한다. 이러한 관점에서 본 연구는 16개의 다양한 측정점을 선정하여 대청댐의 수차 발전기에서 발생하는 소음의 전달특성을 측정 분석하였으며, PSIL, NC 등의 평가지수로 실내소음의 정도를 평가해 보았다. 소음평가 결과 대청댐의 경우 여러 공간에서 소음의 피해 정도는 매우 심각하게 나타나 방음대책이 절실히 필요할 것으로 사료된다. 이러한 자료는 향후 수차 발전소의 효율적인 소음 저감대책과 쾌적한 업무 환경 수립을 위한 유용한 자료로 활용될 수 있을 것으로 사료된다.

전기장 왜란을 이용한 비접촉 스마트 TV 제스처 인식 알고리즘 (Non-Contact Gesture Recognition Algorithm for Smart TV Using Electric Field Disturbance)

  • 조정재;김영철
    • 한국멀티미디어학회논문지
    • /
    • 제17권2호
    • /
    • pp.124-131
    • /
    • 2014
  • 본 논문에서는 4-채널 전위계 센서의 배열을 이용한 비접촉 제스처 인식 알고리즘을 제안한다. 주변의 전기장 변화에 민감한 전위계 센서를 스마트기기의 제스처인식에 활용하기 위해서 실내 환경에서 극저주파 대역 EMI(Electro Magnetic Interference) 및 PLN(Power Line Noise) 영향을 최소화하였다. AC 형태의 입력 데이터 값에 10Hz LPF(Low Pass Filter) 및 H/W 샘플링 속도를 고려한 최대 버퍼 값 추출 알고리즘을 적용하여 선형적인 DC 형태의 데이터로 변형한다. 추가적으로 칼만 필터를 적용함으로써 노이즈를 최소화하며, 센서간의 배열을 고려한 데이터 차분 과정을 통해 목표물의 2차원적 움직임 정보를 추출한다. 추출된 데이터 값과 peak 값의 시차정보를 이용하여 DTW(Dynamic Time Warping) 제스처 인식 및 보정 알고리즘을 구현하였으며, 다섯가지 동작 시나리오 테스트 결과 95% 이상의 높은 인식률을 보였다.

다구찌 방법을 이용한 시로코 홴의 최적설계에 관한 실험적 연구 (An Experimental Study on the Optimum Design of Sirocco Fan by Using Taguchi Method)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.761-768
    • /
    • 1999
  • This paper is studied to find the optimum condition of double-inlet Sirocco fan installed in an indoor PAC for low noise operation by the Taguchi method. The goal of this study is to obtain the best combination of each control factor which results in a desired flowrate of Sirocco fan with minimum variability. In this study, the parameter design of the Taguchi method is adopted for robust design by the dynamic characteristic analysis using orthogonal arrays and S/N ratios. The flowrate measurements are conducted by using a multiple-nozzle-type fan tester according to the orthogonal array L9($3^4$). The results of this study can be summarized as follows ; (i) The optimum condition of control factor is a set of where A is an inner to outer diameter ratio($D_1/D_2$), B is a width to outer diameter ratio($L/D_2$), C is a blade attachment angle(${\theta}$) and D is a number of blade(Z), (ii) The flowrate under the optimum condition satisfies the equation $y=0.0384{\cdot}M$ where M is a signal factor, namely number of revolution. The flowrate performance improves about 7.3% more largely as compared with the current condition, which results in about 35RPM reduction of number of revolution for the target flowrate $18.5m^3/min$, and (iii) The sensitivity analysis shows that the major factors in contribution to flowrate performance are A, B, and D ; the percentage contributions of each control factor are 44.01%(Z), 26.77%($D_1/D_2$) and 20.42%($L/D_2$).

초고층 주상복합아파트 거주자의 주거만족도 (The Residential Satisfaction of Residents in High-rise Mixed-use Apartments)

  • 강순주;이수현
    • 대한가정학회지
    • /
    • 제42권6호
    • /
    • pp.1-12
    • /
    • 2004
  • This study investigates residents' living satisfaction with high-rise, mixed-use apartments built in the structures of reinforced concrete construction(RC) and with steel framed, reinforced concrete construction(SRC). The following study results were obtained: 1) Residents expressed below average satisfaction (below 3.0) with the common-area landscape and environmentally-friendly factors, children's playground and its facilities, community service for residents' by the management offices and utility plan. 2) According to the satisfaction of sound environment, residents of the SRC group expressed above average satisfaction. It can be concluded that noise problems around the residential area of the SRC group was well solved in this study. However, the residents of the SRC group expressed low satisfaction with the freshness of indoor air, humidity, and smell in the living quarters. 3) High-rise, mixed-use apartments should accommodate a familial life cycle, be designed as an environmentally friendly resting place in harmony with city life, and provide various communal programs for residents.