• 제목/요약/키워드: Indoor Noise

검색결과 430건 처리시간 0.026초

청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구 (An Experimental Study on the noise Rating of H.D. TV sets by Psycho-acoustic Experiments)

  • 이주엽;박현구;이태강;김희진;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.862-869
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise in residential condition. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

  • PDF

청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구 (An Experimental Study on the Noise Evaluation of H.D. TV sets by Psycho-acoustic Experiments)

  • 이주엽;이태강;김희진;김선우
    • 한국소음진동공학회논문집
    • /
    • 제16권10호
    • /
    • pp.1014-1023
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. Finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

민항기와 군용기가 혼합된 공항 주변지역의 항공기 소음에 대한 거주자 반응 (Subjective Response for the Aircraft Noise in the Region around Airport mixed with Commercial and Military Aircrafts)

  • 백형배;박현구;김선우
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.99-106
    • /
    • 2009
  • This study aims to survey the acoustical environment in the region around airport where there are various transportation noises such as aircraft noise, railway noise and traffic noise, and to analyze the subjective response on the noise to the people who live in house or work in office nearby airport. Measurement and subjective response evaluation were carried out at the same time and outdoor noise level was measured all day long to calculate one day results such as average Leq or one day WECPNL etc. The results showed that the military aircraft produces very high level comparing with commercial aircraft, for instance the sound level of commercial outdoor was lower than that of military aircraft indoor. Double and triple window were more effective for controlling the noise than single window, which showed the possibility of sound insulation treatment by installing windows having higher sound insulation performance. Finally the subjective response was resulted that the most annoying noise is from aircraft and counterplan they hope is 'airport moving out'. Leq 65 dB(A), the criteria value of sound insulation treatment, was corresponding to the subjective response of median annoyance '4' out of 7th scale.

공동주택 단지 내 주민공동시설의 소음 방지를 위한 공기전달음 차단 성능 현장 조사 (Field Measurement of Airborne Sound Insulation for Noise Reduction about Community Facilities in an Apartment Complex )

  • 성요한;김진식;김혜원;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.249-250
    • /
    • 2023
  • The objective of this study is to evaluate the airborne sound insulation performance between housing units and community facilities during the construction phase. Community facilities adjacent to housing units can lead to noise problems, hence it is necessary to minimize noise transmission during the design phase. However, flanking noise transmitted through gaps of structures, windows, pipes, and other openings may result in substandard sound insulation performance falling below the design standards. Therefore, It is crucial to measure airborne sound insulation in the field during the construction phase. The measurement was conducted using the survey method for the field measurement of the airborne sound insulation in accordance with KS F ISO 10052:2021. Although the noise standards caused by community facilities in apartment complexes are not specified in current laws and regulations, desired noise level was set based on international guidelines for indoor noise. First, the level of noise generated in community facilities was estimated, and then the sound insulation performance was evaluated to determine whether the desired noise level was achieved.

  • PDF

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) in Public Facilities, Korea

  • Kim, Ho-Hyun;Lim, Young-Wook;Jeon, Jun-Min;Kim, Tae-Hun;Lee, Geon-Woo;Lee, Woo-Seok;Lim, Jung-Yun;Shin, Dong-Chun;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권2호
    • /
    • pp.72-84
    • /
    • 2013
  • In the study, pollution levels of indoor polycyclic aromatic hydrocarbons (PAHs) in public facilities (vapor phase or particulate phase) were evaluated, and a health risk assessment (HRA) was carried out based on exposure scenarios. Public facilities in Korea covered by the law, including underground subway stations, funeral halls, child care facilities, internet cafes (PC-rooms), and exhibition facilities (6 locations for each type of facility, for a total of 48 locations), were investigated for indoor assessment. For the HRA, individual excess cancer risk (ECR) was estimated by applying main toxic equivalency factor (TEF) values suggested in previous studies. Among the eight public facilities, internet cafes showed the highest average $PM_{2.5}$ concentration at $110.0{\mu}g/m^3$ (range: $83.5-138.5{\mu}g/m^3$). When assuming a risk of facility exposure time based upon the results of the surveys for each public facility, the excess cancer risk using the benzo(a)pyrene indicator assessment method was estimated to be $10^{-7}-10^{-6}$ levels for each facility. Based on the risk associated with various TEF values, the excess cancer risk based upon the seven types cancer EPA (1993) and Malcolm & Dobson's (1994) assessment method was estimated to be $10^{-7}-10^{-5}$ for each facility. The excess cancer risk estimated from the TEF EPA (2010) assessment was the highest: $10^{-7}-10^{-4}$ for each facility. This is due to the 10-fold difference between the TEF of dibenzo(a,e)fluoranthene in 2010 and in 1994. The internet cafes where smoking was the clear pollutant showed the highest risk level of $10^{-4}$, which exceeded the World Health Organization's recommended risk of $1{\times}10^{-6}$. All facilities, with the exception of internet cafes, showed a $10^{-6}$ risk level. However, when the TEFs values of the US EPA (2010) were applied, the risk of most facilities in this study exceeded $1{\times}10^{-6}$.

전력용 변압기 철심소음 저감기술에 관한 연구 (A Study on the Core Noise Reduction Techniques of Power Transformers)

  • 권동진;구교선;조익춘;김유현;김융식
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1962-1969
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint is increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation of the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated core noise reduction techniques to develope a low noise transformer. The techniques to reduce core noise of the transformer are application of high permeability grain oriented silicon sheets, decrease of magnetic flux density of core, application of 6step-lap core stacking method, improvement of core binding method(binding addition, band fixing) and application of rubber damper in oder to reduce transmission of core vibration, etc.

분리형 에어컨의 실내기 냉매 소음 저감 분석 (Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit)

  • 시케오 아오야마;모진용;이재권;송용재;한형석
    • 한국소음진동공학회논문집
    • /
    • 제16권3호
    • /
    • pp.240-246
    • /
    • 2006
  • In the air-conditioner, refrigerant induced noise and vibration can be increased when the airflow rate is reduced in order to decrease the noise at the low mode. Through the test and analysis of this kind of noise, it can be verified that the main reasons of refrigerant induced noise are the velocity and flow Induced force of the refrigerant at the inlet of the evaporator, So, in order to reduce this velocity, quality at the evaporator inlet should be minimized. And, in order to reduce flow induced force of the refrigerant, sudden change of fluid flow must not be occurred. So, in this paper, we will review the characteristics of refrigerant cycle and find how the quality and flow induced force can be minimized.

오피스 건물의 실내 환경 실태 조사 (The Field Survey of Indoor Environment of the Office Building)

  • 양영권;강인성;정민희;문진우;박진철
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.71-76
    • /
    • 2016
  • Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms.

깊이 측정 카메라를 이용한 실내 위치결정 방법 (A Method for Indoor Positioning Utilizing Depth Camera)

  • 김석진;전승현;이태관;김승오;박채린;구본근
    • Journal of Platform Technology
    • /
    • 제12권1호
    • /
    • pp.44-54
    • /
    • 2024
  • 비콘 또는 태그를 이용한 기존 실내 위치결정 방법은 상황에 따라 검출하지 못하거나 잡음에 의한 오차가 증가하는 문제가 있다. 본 논문에서는 위치가 알려져 있는 대상 객체와의 거리와 로봇의 정면 방향에서 대상 개체를 보는 방향 사이의 각도를 이용하여 로봇의 실내 위치를 결정하는 방법을 제안한다. 본 논문에서 제안하는 방법은 거리를 측정하고, 각도를 계산하기 위해 깊이 측정 카메라를 이용한다. 거리는 카메라가 측정한 깊이 정보를 이용하며, 각도는 카메라가 캡처한 이미지를 이용하여 대상 객체의 각도를 결정한다. 본 논문에서 제안한 방법은 거리 정보와 각도 정보를 이용하여 좌표 변위를 계산하고, 이 변위와 대상 객체의 좌표를 이용하여 이동 로봇의 위치를 결정한다. 본 논문에서 제안한 방법이 실내 위치결정에 사용될 수 있음을 보이기 위해 시험 구현하여 실측한 변위 비교하였다. 그 결과 50mm 이내의 오차가 있었지만 이동 로봇의 크기를 고려할 때 본 논문에서 제안한 방법이 실내 위치결정에 충분히 사용될 수 있다고 판단된다.

  • PDF

함정 격실에 적용되는 흡음재와 잔향시간에 따른 실내 소음 분석 (Investigation of the Indoor Noise of Naval Vessel according to the Sound Absorption and Reverberation Time in a Cabin)

  • 한형석;박미유;조흥기;김중길;임동빈;손윤준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.586-591
    • /
    • 2010
  • The sound field can be classified to the direct and reverberant sound field. If the sound absorption material in a room is not applied sufficiently, the reverberant sound field increases and the sound pressure in a room also increases when the sound source exists in a room. Therefore, the reverberation time should be controled in order to reduce the reverberant sound as well as sound pressure level in a room. Even though the reverberation time is specified and researched widely in architectural engineering, it is rarely performed in a marine engineering. Therefore, in this research, the reverberation time in a navel vessel is researched related to the noise reduction in a cabin.

  • PDF