• 제목/요약/키워드: Indoor Noise

검색결과 429건 처리시간 0.03초

Blind Signal Processing for Wireless Sensor Networks

  • Kim, Namyong;Byun, Hyung-Gi
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.158-164
    • /
    • 2014
  • In indoor sensor networks equalization algorithms based on the minimization of Euclidean distance (MED) for the distributions of constant modulus error (CME) have yielded superior performance in compensating for signal distortions induced from optical fiber links, wireless-links and for impulsive noise problems. One main drawback of MED-CME algorithms is a heavy computational burden hindering its implementation. In this paper, a recursive gradient estimation for weight updates of the MED-CME algorithm is proposed for reducing the operations $O(N^2)$ of the conventional MED-CME to O(N) at each iteration time for N data-block size. From the simulation results of the proposed recursive method producing exactly the same results as the conventional method, the proposed estimation method can be considered to be a reliable candidate for implementation of efficient receivers in indoor sensor networks.

현장측정을 통한 발코니 창호의 차음성능에 관한 연구 (Investigation of the sound insulation performance of balcony window through field measurement)

  • 주문기
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.63-68
    • /
    • 2009
  • As with the disappearance of a living room window due to the trend in apartment housing construction that prefers a larger, expanded living room, the sound insulation performance of the balcony window is becoming an important factor to determine the level of indoor noise at an apartment unit. Considering that the indoor noise inside an apartment unit is mandated by law at or below 45dB(A), the balcony window is increasingly assuming an even more important role. Sound insulation performance of the window was measured by examining differences in data involving varying angles of incidence of the sound source as obtained from the same balcony window. Also, acoustic intensity measuring was performed at and around the window to determine its sound insulation quality. Results of measuring on the sound source's angles of incidence indicated that the performance showed some differences in lower frequency ranges, though with no significance. Intensity measuring results showed that the sound insulation performance was reduced near the connection part of the window and the window frame.

공기조화 취출구 소음 평가를 위한 물리지수 분석 (Analysis of Physical Parameters for the Evaluation of HVAC Diffuser Noise)

  • 박현구;김항;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.402-405
    • /
    • 2006
  • The diffuser noise of HVAC(heating ventilating and air-conditioning) uses dB(A) or NC as a indoor noise criteria that ASHRAE represents, and there is no specific guide line for application. According to the previous study, there are some problems like that even though the sound level of sound source is same, the NC shows different values, which makes the noise rating confused. This problem is caused by the frequency characteristics of sound source and its sound level. Therefore, appropriate evaluation method should be considered based on the subjective responses. This study aims to analyze the physical parameters appropriate for the evaluation of HVAC diffuser noise. To achieve this, recording of sound sources, calculation of physical parameters and psycho-acoustic experiment were carried out and the results were derived from the correlation analysis between physical parameters and subjective evaluatio

  • PDF

인공잡음 발생장치를 이용한 초고압 시험선로의 잡음 방사특성 연구 (A Study on the Radiation Characteristics of Noise from HV AC Transmission Lines Using a Gap Noise Generator)

  • 신구용;이동일;김상범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2041-2043
    • /
    • 1999
  • In order to investigate the radiation characteristics of unmixed line noise from overhead high voltage AC transmission lines, a gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by charge simulation method. The capacitance is one of principal parameters related to inject a proper noise current into lines. The field experiments were performed with the noise generator installed in Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines was obtained. Those are lateral profiles the directivity of antenna toward lines, frequency spectra and so on.

  • PDF

도상흡음재의 도상시험에 관한 고찰 (A Study on noise measurement result of track noise absorber)

  • 김진호;한석윤;정장용;문제우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1038-1042
    • /
    • 2008
  • The construction of concrete slab track system is increased recently but the noise level on slab track is 3dB(A) higher than the one on ballast track since most of noise is reflected on slab track. Currently, concrete slab track systems has been designed for Gyungbu high speed line stage 2 and Honam high speed line. For those tracks, noise absorbing blocks are considered. In this paper, noise absorbing blocks were installed at Hwang Hak tunnel for evaluation of noise absorbing blocks and the indoor noise of KTX was measured. The results have done comparative analysis.

  • PDF

아파트의 내부 생활소음레벨 및 소음종류 실태 (Present Condition on Noise Level and Types Including Residents' Living Noise in Apartment Units)

  • 최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.427-430
    • /
    • 2008
  • The present study is a preliminary research improving the dwelling quality of apartment house as a kind of multi-family housing. The purpose of the study is to find out the present condition on noise level and types including residents' living noise in apartment units. The method was field survey consisted of field measurements on equivalent noise level, observation on noise type, and interview on residents' responses. The results are as follows. 1) Averages of indoor noise levels of subject houses were measured as $43.9{\sim}62.2\;dB(A)_{Leq5min}$, the average of each house except one was higher than the permissible level, 45 dB(A). 2) The noise types observed were mostly residents' living noise and classified as 'water hammer', 'living equipment noise', 'noise by family', 'hood noise', and 'kitchen noise' in own unit, 'walking and talking noise in stairs and corridors', 'noise by neighborhood house', 'noise by the upper story' in building, and outdoor noise. 3) The residents show slightly non-positive responses at 'noise by the upper story', 'noise by neighborhood house', 'water hammer', and 'noise by family'. Therefore, it is required to plan for preventing deterioration of the sound environment quality by residents' living noise in own unit as well as by neighborhood houses.

  • PDF

공동주택 급배수 설비소음의 실태 및 저감방안에 관한 연구 (A Study on the Actual Survey and Reduction of Plumbing Noise in Apartment Houses)

  • 김흥식;지용균;윤세철
    • 한국음향학회지
    • /
    • 제9권4호
    • /
    • pp.45-54
    • /
    • 1990
  • 급 배수 설비소음은 공동주택 내부소음의 설문조사 결과, 상하층간 바닥충격음과 함께 거주자에게 두드러진 불만요소로써 나타나고 있다. 본 연구에서는 이러한 공동주택 급배수 설비소음의 실태를 측정하고 실태조사와 급수관의 고체전달음 및 배수음의 저감 모델 실험 결과를 중심으로 급배수 설비소음에 관한 공법상의 저감방안을 제시하였다.

  • PDF

함정의 전투체계 콘솔 냉각 홴 소음저감을 위한 프리넘 챔버 설계 (Design of the Plenum Chamber for Reducing Cooling Fan Noise of the Console for Combat Systems in a Naval Vessel)

  • 한형석;박미유;조흥기;김중길;임동빈
    • 한국소음진동공학회논문집
    • /
    • 제21권6호
    • /
    • pp.529-535
    • /
    • 2011
  • Indoor noise is very important related to the morale and fighting power of the crew as well as environmental condition for them in a navel vessel. Especially, the crew members working in CIC (combat information center) and sonar equipment room require much more quiet environment condition. One of the most serious noise source in CIC is the cooling fan noise installed in the console of the combat system. Therefore, in this paper, the design of the plenum chamber is studied to reduce the noise of the fan from these consoles by numerical analysis and experiment.

함정의 전투체계 콘솔 냉각 팬 소음 저감을 위한 프리넘 챔버 설계 (Design of the Plenum Chamber for Reducing Cooling Fan Noise of the Console for Combat Systems in a Naval Vessel)

  • 한형석;박미유;조흥기;김중길;임동빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.77-82
    • /
    • 2011
  • Indoor noise is very important related to the morale and fighting power of the crew as well as environmental condition for them in a navel vessel. Especially, the crew members working in CIC(Combat Information Center) and sonar equipment room require much more quiet environment condition in order to increase the performance of their combat system. One of the most serious noise source in CIC is the cooling fan noise installed in the console of the combat system. Therefore, in this paper, the design of the plenum chamber is studied to reduce the noise of the fan from these consoles by numerical analysis.

  • PDF

An Experimental Study for Noise Reduction of the Cross-Flow Fan of the Room Air-Conditioners

  • Koo, Hyoung-Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.89-100
    • /
    • 2000
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectra of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed, which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared with and without the bounding fence for various flow rates.

  • PDF