An Enhanced MAC Protocol Based on FDD for Reducing The Delay in Visible LAN Systems (가시광 무선 랜 시스템에서 통신지연 감소를 위한 FDD 기반의 개선된 MAC 프로토콜)

  • Hwang, Junho;Yoo, Myungsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.3-10
    • /
    • 2012
  • The visible light communication takes advantages of LED and PD for communication and is considered as a next generation wireless communication technology. It can support variety indoor applications. Especially, Visible LAN service has drawn much attention due to high data rate and no interference with existing WPAN system as well as high efficiency in illumination. However, existing MAC protocol occurs a high communication delay due to uplink collision and backoff time. In this paper, to reduce packet delay, we propose an enhanced MAC protocol based on FDD where the time difference between uplink frame and downlink frame transmission is utilized. Through computer simulations, we verified that the proposed MAC protocol outperforms the existing MAC protocol in terms of average packet delay.

Design and Implementation of Sensibilities Lighting LED Controller for a Ship (선박용 감성조명 LED 제어기의 설계 및 구현)

  • Lee, Jae-Hong;Park, Ju-Won;Lim, Jin-Kang;Lee, Sang-Bae
    • Journal of Navigation and Port Research
    • /
    • v.34 no.10
    • /
    • pp.763-768
    • /
    • 2010
  • Today the light of mankind since the dawn of mankind and that they were living "lives" on the huge influence across space is a dynamic energy. Because of this, when all human beings with the light and you can feel more comfortable with a stable mind to the beauty and the pursuit of happiness is to have instincts. In this paper, a fuzzy control system using a combination of external environmental factors, respectively, the conversion of quantitative uncertainty information into the LED lighting is designed to express algorithms, available in indoor circadian control circuit was designed and fabricated LED. Factor in the external environment temperature, humidity, and light intensity values to the controller through the sensor to accept these values and the optimal values for lighting the fuzzy control algorithm is converted into human emotion to feel comfortable to express through the dimming control LED lighting.

Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position (확산필름 부착 위치에 따른 광선반 성능개선 연구)

  • Park, Eunsu;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.

Performance Comparison of Skin Color Detection Algorithms by the Changes of Backgrounds (배경의 변화에 따른 피부색상 검출 알고리즘의 성능 비교)

  • Jang, Seok-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.27-35
    • /
    • 2010
  • Accurately extracting skin color regions is very important in various areas such as face recognition and tracking, facial expression recognition, adult image identification, health-care, and so forth. In this paper, we evaluate the performances of several skin color detection algorithms in indoor environments by changing the distance between the camera and the object as well as the background colors of the object. The distance is from 60cm to 120cm and the background colors are white, black, orange, pink, and yellow, respectively. The algorithms that we use for the performance evaluation are Peer algorithm, NNYUV, NNHSV, LutYUV, and Kimset algorithm. The experimental results show that NNHSV, NNYUV and LutYUV algorithm are stable, but the other algorithms are somewhat sensitive to the changes of backgrounds. As a result, we expect that the comparative experimental results of this paper will be used very effectively when developing a new skin color extraction algorithm which are very robust to dynamic real environments.

Study of the Optical System Design of a Reflective LED Stand to Reduce Glare (눈부심 감소를 위한 반사형 LED 스탠드 광학계 설계에 관한 연구)

  • Kong, Mi-Seon;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.334-343
    • /
    • 2020
  • In this paper, a study of the design of a lighting optical system to form indirect light was conducted, to reduce the glare caused by the hot spot of the LED. In the case of using an LED for indoor lighting, glare is caused because of the high luminance and non-uniform luminance distribution. In particular, LED stands are located close to the user's eyes and are used for a long time, so research to reduce glare is essential. Therefore, in this paper an optical system structural study and the design of an LED stand for glare reduction were conducted. Afterward, the luminance analysis and comparison to an existing LED stand product confirmed that the reflective LED stand proposed in this paper had better performance in terms of glare.

Study on the Indoor Environment and Status of Facilities and Equipments of Home Economics Practice Rooms of Middle Schools in Jeju Special Self-Governing Province (제주특별자치도 중학교 가정실의 실내환경 및 시설.설비 현황에 관한 연구)

  • Park, Min-Hye;Kim, Bong-Ae
    • Journal of Korean Home Economics Education Association
    • /
    • v.19 no.3
    • /
    • pp.61-76
    • /
    • 2007
  • The purpose of the study is to identify and understand problems existing in the middle school home economics practice rooms in Jeju Special Self-Governing Province. The findings are based on the examination and the analysis of the indoor environment and the condition of the facilities and equipment. Study method employs on-site research and a survey. The on-site research was conducted about temperature, humidity, intensity of illumination, and status of teaching instrument in 10 out of 41 middle schools in Jeju Special Self-Governing Province from August 16 to September 30, 2006. Meanwhile, the survey was implemented by mail for 95 teachers in charge of manual training and home economics education in 41 middle schools in Jeju from November 1 to 23, 2005. 64 questionnaires out of total 95 were collected, including those collected during the period of on-site research. Finally, 61 questionnaires which were effective among the answered ones were used for analysis. Collected materials were analyzed with the SPSS Win.12.0 program for frequency, percentile analysis. In conclusion, the study determines that the condition of the home economics practice rooms of the middle school in JSSGP in terms of temperature, humidity, lighting and ventilation is very inadequate. The structure of the practice room represents an inefficient work flow pattern. Further, the facilities and equipment are in a very poor condition because the facilities are old and the retention rate of teaching tools is low. Therefore, to address these problems, the study suggests that improvements on the facilities and equipment should be made and teaching tools should be replenished in accordance with the industry standard.

  • PDF

Status of Industrial Environments of Some Industries in Taegu Kyungpook Area (대구지방 산업장에 있어서 건강장애요인과 작업환경검사에 대한 기업인의 수용태도 (ll))

  • Kim, Du-Hui;Seong, Su-Won
    • 월간산업보건
    • /
    • s.8
    • /
    • pp.4-30
    • /
    • 1988
  • Examination of working environments was conducted to get more detailed data about harmful working environments and to make a contribution to more effective management. Study was carried out on 722 factories located in Taegu city and eight counties in Kyungpook Province, Korea, for a period of one year, from February 1 to December 30, 1986. The total number and proportion of workers exposed to harmful material was 37,697, 45.2% among 83,368 workers. The results according to exposed material were as follows: 1. In the case of noise, proportion of exceeding the 8-hour TLV was 59%, Included were nail-cutting in assembly metal manufacturing industry and weaving process in textile. 2. Dust in mill process of coal manufacturing industries exceeded the TLV of second class of dust at all parts and exceeded the TLV at 6% as a whole.: 3. The fields of industry lower than 70 lux of illumination were storage equipment of food, auto-winder of textile, painting of wood wares and coal mixing, and 44% of all cases was lower than standard. 4. As a result of temperature index investigation(WBGT), about 12% of all sujects exceeded limit value. Included parts were rolling machine and reducing room. 5. In the case of organic solvents, TLV was exceeded at about 8%, The parts exceeded TLV according to materials belonged to this category were as follows. 1) Toluene: adhesive work in assembly metal manufacturing 2) Xylene: printing and paint mixing in chemical manufacturing 3) Methyl ethytl ketone: paint mixing in all parts examined and coating machine partially in chemical manufacturing 4) Methyl isobutyl ketone: printing in chemical manufacturing 5) Acetone: vapor polishing in assembly metal manufacturing 6. Among specified chemical materials, the concentration of HC1 in the air in metal assembly manufacturing factory exceeded TLV. in one of three assembly metal manufacturing examined. Others, such as benzene, acetic acid, formic acid, sodium hydroxide, formalin, ammonia, copper, chromate etc. were lower than TLV in its indoor atmospheric concentration. As a whole, the proportion of exceeding TLV was about 0.8% 7. The concentrations of inorganic lead were lower than TLV in all parts examined. The results of this investigation show the fact that current management of working environments is not satisfactory, and so more active management is needed.

  • PDF

Effects of Presown Cold Stratification, $GA_3,\;KNO_3$ and Acetone Treatment on Germination of Crotalaria sessiflora L. (저온, $GA_3,\;KNO_3$ 및 Acetone 처리가 활나물 종자발아에 미치는 영향)

  • Kang, Jin-Ho;Kim, Yu-Jin;Jeon, Byong-Sam
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.2
    • /
    • pp.124-129
    • /
    • 2001
  • Crotalaria sessiflora is one of a few medicinal herbs among the legumes used as antitumor herb medicine but has lower seed germination and afterward seedling emergence. This study was carried out to elucidate the effects of cold stratification as presown treatment as well as $GA_3$, $KNO_3$ and acetone on its seed germination and seedling emergence. Cold stratification, $GA_3$, $KNO_3$ and acetone treatments were performed with different concentrations and period levels. Cold treatment was done under 14 hour red light illumination a day or darkness and the two others under darkness. On the basis of the best germination rate of each treatment, $GA_3$ and cold stratification treatments showed the highest germination rates at 0.1 mM but 12 hours and 2 week periods under darkness, respectively. $KNO_3$ and acetone treatments came out at 400 mM and 200 mM lasted for, respectively. The best germination rates from $KNO_3$ and acetone were comparatively higher than those from the former $GA_3$ and cold treatments. In evaluation of seedling emergence using the last two treatments, $KNO_3$ treated seeds were better performed than acetone treated seeds showed somewhat higher germination rate, implying that presown seed treatments must be evaluated by the combination with indoor and field tests.

  • PDF

Seed Treatment Procedure to Promote Seedling Emergence of Platycodon grandiflorum (도라지의 입묘율 향상을 위한 종자처리의 모형화)

  • Kang, Jin-Ho;Shim, Young-Do;Jeon, Byong-Sam
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.2
    • /
    • pp.75-81
    • /
    • 2002
  • Indoor seed treatments to elevate seedling emergence should be of value. The study was done to model the presown treatments of Platycodon grandiflorum seeds by evaluating the treatment effects of priming,$GA_3$, drying and water imbibition after drying on their germination and then their successive seed treatments on the basis of its seedling emergence. after priming using $Ca(NO_3)_2\;and\;GA_3$ treatment under their different concentrations and light quality illuminated for 12 hours a day were done separately and their two best results were compared to determine the better one, drying of imbibed seeds using the above best result and water imbibition of the dried seeds were successively done to check the rates of germination and emergence. In each treatment of priming and $GA_3$, the former best germination occurred at $Ca(NO_3)_2$ 150 mM done under 2 day darkness but the latter one did at 0.01 mM done under 12 hour a day red light forced for 3 days. Of the two best results from priming and $GA_3$ treatments, the latter result was shown higher germination rate. $GA_3$ treated seeds were best desiccated under $35^{\circ}C$ and 4 hour red light illumination. The germination rate of seeds dried after $GA_3$ treatment was enhanced as imibibed 2 days immediately before sowing. Seedling emergence of all 3 successive treatments, $GA_3$, drying and water imbibition before sowing was the greatest than the two others, only $GA_3$ treatment and the combination of $GA_3$ and drying, in which indicated that its presown seed treatment must follow the successive procedure of the above 3 ones.

Effects of irradiation periods on the Lettuce Growth (광원 조사기간이 상추생육에 미치는 영향)

  • Kim, Dong-Eok;Kim, Bong-Soo;Kim, Hyun-Bae;Yoon, Yong-Cheol;Kim, Chi-Ho;Kim, Hyeon-Tae
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.4
    • /
    • pp.459-466
    • /
    • 2012
  • The objective of this study is to observe growth pattern of grand rapids(lettuce) according to different dexperimental conditions for minimizing its growth period such as composition of nutrient, irradiation time of light source and cultivation mode. The culture of water spray type using seeds of grand rapids was performed during growth period of total 50 days. Experimental conditions consist of five compositions of nutrient (PW 0.5 mS/cm, PW 1.0 mS/cm, PY 0.5 mS/cm, PY 1.0 mS/cm, PW 2.0 mS/cm) and three irradiation times of light source (12h(on) / 12h(off), 18h(on) / 06h(off), 24h(on) / 00h(off)). Illumination was adjusted to ratio of 7:1:1 of red, blue and white color, respectively. Indoor environmental condition for cultivating grand rapids is as follows: temperature (19-$22^{\circ}C$), relative humidity (60-70%) and carbon dioxide (1,000-1,200 ppm). The data were obtained from five iteration tests. The maximum growth level was observed in the experimental condition of 18 hr(on) / 06 hr(off) and PY 1 mS/cm for 1st week of cultivation period, 24 hr(on) / 00 hr(off) and PY 1mS/cm for 2nd week of cultivation period, and 24 hr(on) / 00hr(off) and PW 1 mS/cm for 3rd week of cultivation period, respectively. On the contrary, the minimum growth level was observed in the experimental condition of 18 hr(on) / 06 hr(off) and PW 0.5 mS/cm for 1st week of cultivation period, 12 hr(on) / 12 hr(off) and PW 0.5 mS/cm for 2nd week of cultivation period, and 12 hr(on) / 12 hr(off) and PY 0.5 mS/cm for 3rd week of cultivation period, respectively. Based on the results obtained from this study, it is concluded that the growth level of grand rapids varied with different irradiation time of light source and composition ratio of nutrient according to cultivation period.