• 제목/요약/키워드: Indoor Environmental Items

검색결과 44건 처리시간 0.02초

병원건축의 친환경 성능 향상을 위한 국내외 친환경 건축물 평가항목의 비교 연구 (A Comparative Study of a Domestic and Foreign Green Architecture Evaluation Items for a Green Performance Enhancement of Hospital Architecture)

  • 이호성
    • 한국실내디자인학회논문집
    • /
    • 제18권1호
    • /
    • pp.99-107
    • /
    • 2009
  • In order to prepare future green hospital architecture authentication system, this study is a comparative year report to Korean, the United States, Japanese, British, Canadian and Australian green building authentication systems. Also, the United States and Australian Green hospital authentication systems were examined, and the authentication items of hospitals were compared with those of civil architecture. Though the examination and analysis, the portion of indoor environmental quality section commonly shows the average of 20.7 percent in all 6 countries. Especially, IAQ(Indoor Air Quality) among inside IEQ(Indoor Environment Quality) is overwhelmingly much treated in Korea, the U.S.A, Canada and Australia. In Japan, heat, light and sound are the important factors for authentication evaluation, while in the U.K light are more emphasized for the authentication. 'LEED for Healthcare' as a hospital evaluation authentication system subdivided currently most. The system includes the detailed and extensive evaluation items ranging from hospital management, traffic, emission, water resources utilization to integrated design and furnishing. These overseas systems should be carefully investigated, researched and analyzed for an appropriate improvement of domestic green hospital authentication system. Also the current evaluation method of IEQ section of Korean GBCC needs to be modified. That's why the method puts too much importance on IAQ in IEQ section.

A Study on Lighting Environmental Evaluation of Senior Welfare Centers Based on biophilia

  • Yang, So Yeon;Lee, Tae Kyung
    • Architectural research
    • /
    • 제22권4호
    • /
    • pp.123-133
    • /
    • 2020
  • Light is an essential environmental element for elderly people to do various activities. At senior welfare centers, healthy indoor lighting is especially necessary because the facilities are used by the elderly to perform their mostly indoor activities. The purpose of this study is to evaluate light environments at senior welfare centers for well-being lighting characteristics. We based the study on the 'Biophilia' theory, a concept related to health from happiness. Thus, this study is mainly based on literary review and survey research. For this, we conducted a location focused field study to identify the current state of the lighting environments at senior welfare centers in Busan, South Korea. First, we constructed structural questionnaire to evaluate lighting environment based on 'Light and Space' biophilia theory. Then, to survey subjective evaluation, the participant of research included total of 122 senior welfare center users. Based on the results of this research, the conclusions are as follows; 1) overall, it seems that the overall result of the light environmental evaluation seems to be high because the evaluated facilities in the case survey in large-scale were recently built elderly welfare centers. 2) most of the healing design elements are focused on the introduction of natural light and psychological influence. The satisfaction with actual natural light is evaluated to be high. Although shadow and reflected light are very important in discrimination and recognition of indoor space and wayfinding, the evaluation of reflected light and shadow was low for the study. 3) items that are related to the functionality of the light were highly evaluated, while the items that are related to the spatiality of the light were rated poorly. This study has its significance when examining the effects of light environments within the welfare center form of the perspective of senior citizens. It can be referenced when reconsidering the recognition of light environment as a major consideration factor to establish a desirable senior welfare center environment.

아파트 거주 고령자의 운동실태 및 실내운동시설 평가 (Current Status of Exercise and Evaluation of Indoor Exercise Environment of Seniors Living in Apartment Complex)

  • 오찬옥;권현주
    • 한국실내디자인학회논문집
    • /
    • 제27권2호
    • /
    • pp.166-174
    • /
    • 2018
  • This study examined the indoor exercise environment use and needs of older adults. The target population was seniors aged 60 years and older living in a newly developed apartment complex. Variables include demographic and housing characteristics, status of exercise, and indoor exercise environmental evaluation and needs. A total of 102 data items were analyzed using frequency, t-test and ANOVA. Noteworthy results are as below. First, community centers and community welfare centers were the most desirable exercise environments because of affordability, exercise programs/spaces. Such exercise environments should be developed in more locations for increasing numbers of seniors. Second, indoor exercise environments need to be improved based on seniors' physical capabilities and environmental behavior. Third, supportive spaces such as restrooms, shower rooms, locker rooms should be carefully designed. Fourth, seniors wanted to have walking trails and indoor swimming pools, the most desirable exercise spaces, within ten to 15 minutes walking distance.

Assessment Items of Outdoor Environment through Analysis of SITES - Focused on the Comparison with G-SEED and LEED -

  • Lee, Hyung-Sook
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.11-18
    • /
    • 2014
  • Although assessing outdoor environment and green space in terms of sustainability and environmental performance is perceived as an important issue, most existing green building certification systems are more focused on buildings and indoor environment. Recently, the Sustainable Site Initiatives (SITES) has been developed by American Society of Landscape Architecture in order to evaluate sustainability of site development and outdoor environment. Separate from LEED, the SITES are increasingly receiving attentions as a reliable certification system in the United States. As a preliminary study to develop the items of outdoor environmental assessment, the present study is purposed to analyze the assessment items, grading system and applicability of SITES for better understanding on the system. Also it was compared to existing green building certification criteria, including G-SEED, LEED-NC, and LEED-ND in order to investigate similarities and discrepancies. The results would provide insights and basic data to improve assessment items for outdoor environment of G-SEED.

친환경 학교건축물 인증사례를 통한 실내환경 평가항목에 대한 분석 연구 (A Study on the Analysis about Assessment Items of the Eco-friendly Certified Schools' Indoor Environment through the Cases)

  • 이용환
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.3-10
    • /
    • 2009
  • There are more interests and studies to change the buildings into eco-friendly spaces as the present age recognizes nature-friendly environment more and more. In response to this trend, the government reinforces regulations for the variety of the eco-friendly buildings using a certification system. The eco-friendly certification system which was started only for residing since 2002, and this has been now for schools that are the spaces of the students who will lead the future since March 2005. The purpose of this study is to help understanding of the eco-friendly buildings, and to popularize and activate those as developing and making up for the classification system, evaluation items, detailed standards to evaluate them more precisely by analysing eco-friendly planning features and data of the eco-friendly certificated schools. This study selected 15 eco-friendly certified schools among the schools certified by the Ministry of Land, Transport, and Maritime Affaires since 2005, and analyzed evaluation result. After the analysis, I had a thorough grasp of the point distribution of the each building, analyzed the cause of the low points or no points, and tried to find the improvements. There should be continuing adjustment and complement for the evaluation items and detailed standards, and these should be applied to models as well as certified schools. Active public relations are also needed to educate the public and elevate their participation.

수영장 활동공간 내 유해인자 노출특성 연구 (Characteristics of Exposure Distribution to Hazard Factors in Indoor Swimming Pool Activity Areas in Gwangju)

  • 이윤국;김난희;최영섭;김선정;박주현;강유미;배석진;서계원;김종민
    • 한국환경보건학회지
    • /
    • 제46권2호
    • /
    • pp.150-158
    • /
    • 2020
  • Objective: This study is designed to measure the concentration of DBPs (disinfection by-products) in pool water and in air and to estimate the carcinogenic potential through the evaluation of inhalation exposure. Methods: The subjects were six indoor swimming pools with many users in Gwangju. Samples of pool water and indoor air were taken every one month from August 2018 to August 2019 and analyzed for eight swimming pool standards. Three-liter air samples were collected and the VOCs were analyzed using GC/MS directly connected to thermal desorption. Results: pH was 6.8-7.5 and the concentration of free residual chlorine in pool water was 0.40-0.96 ?/ℓ. Physicochemical test items such as KMnO4 consumption and heavy metal items such as Aluminum met existing pool hygiene standards. No VOC materials were detected except for the DBPs. The concentration of THMs in the pool water was 11.05-41.77 ㎍/L and the THMs mainly consist of Chloroform (63-97%) and BDCM (3-31%). The concentration of indoor air THMs is 13.24-32.48 ㎍/㎥ and consists of Chloroform. The results of carcinogenic assessment of chloroform in the indoor swimming pool via inhalation exposure were 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA. Conclusions: The concentration of THMs in the pool water is 11.05-41.77 ㎍/L, most of which is chloroform. In addition, the concentration of indoor air THMs is 13.24-32.48 ㎍/㎥. The result of carcinogenic assessment of chloroform was 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA.

네일샵 종사자의 휘발성유기화합물 노출실태와 건강에 미치는 영향 (Health effects on workers and actual exposure of VOCs in the nail shops)

  • 김난희;민경우;조광운;서동주;임경훈;정원삼;조영관;양진석
    • 한국산업보건학회지
    • /
    • 제27권1호
    • /
    • pp.59-69
    • /
    • 2017
  • Objectives: The objective of this study is to evaluate the exposure of VOCs and effects of the chemicals on the nail technicians whose works in a nail shop. Methods: For four month from May to August in 2016, we measured twenty-two kinds of VOCs in ten nail shops and carried out health examinations on thirty-four workers in there. Results: The TVOC concentration in indoor air of nail shops is $0.487mg/m^3$ at a minimum and $33.236mg/m^3$ at a maximum where it consists of 70.5% of Ketones, 25.4% of Alcohols, 2.6% of Esters, 0.8% of Aldehydes and 0.7% of Aromatics. The VOCs concentration during nail art works shows an increase in average ratio 1.8 compared to the concentration of indoor air quality and also the concentration of Isopropanol rose with 3.2 of the highest ratio. The results of Spearman correlation between TVOC concentration in indoor air and environmental factor was like that has significance level of correlation(${\rho}$<0.05, r=0.682) in case of number of customers per day, but the other factors were not meaningful in correlation. Correlation between VOCs and medical check-up items was like that has positive significance level(${\rho}$<0.01, r=0.638) between isopropanol and GPT, but the others have not meaningful. The exposure level of VOCs was not exceed the criteria exposure level 1 of working environment measuring method which announced by labor ministry in all ten nail shop indoor air quality. Conclusions: In this study although it was not significant correlation between harmful substances and medical check-up items in the nail shop indoor air quality, it is necessary to do more ventilation and to install exhaust facilities because of existing high VOCs concentration in the nail shop indoor air.

서울시 환경보건정책 로드맵 수립 (Process and Results of Seoul Metropolitan Government's Environmental Health Policy Road Map)

  • 임지애;권호장;김신범;최영은;구슬기;정회성;김명한;최경호
    • 한국환경보건학회지
    • /
    • 제40권5호
    • /
    • pp.425-434
    • /
    • 2014
  • Objectives: The purpose of this study is to introduce the establishment process and results of the Seoul Metropolitan Government's road map on environmental health policy. Methods: The process consisted of expert group meetings, civic participation, research, and questionnaire survey for priority environmental health policy agenda items in Seoul. Results: The announced vision for the environmental health policy was "a healthy environment, safety in Seoul". This policy was established in order to define environment health policy initiatives for a period of five years with an aim to protect Seoul citizens' health from hazardous environmental factors. The resulting Seoul environmental health policy consisted of four areas and 16 key agenda items. The four areas were "Protection for children against hazardous materials", "Enhancement of health and safety of all", "Carcinogen-free and endocrine-disrupting chemical-free Seoul (reducing environmental exposure to hazardous materials), and "Establish the foundation of environmental health policy". Sixteen key agenda items include the enhancement of management of spaces for children, certification of environmental health status at schools, establishment of a unit responsible for the environmental health of children, strengthening environmental health management for susceptible populations (children, the aged, and the socioeconomically vulnerable), management of hazardous materials, physical hazardous factors (noise, radiation, etc.), indoor air quality, and the enhancement of monitoring, research, and regulation of environment health. Conclusion: The Seoul Metropolitan Government established an environmental health policy road map for a five-year period (2013-2017). To implement this environmental health policy, budget allocation, and detailed execution plans are required.

휴대용 XRF를 이용한 서울시 학교 내 어린이용품 중 일부 유해물질 함량 조사 (Measurement of Hazardous Substances in Children's Goods at Schools in Seoul)

  • 김규상;박현경;최길용;임완령;신규진
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.176-184
    • /
    • 2017
  • Objectives: Excluding in their homes, children spend most of their time at an elementary school, daycare center, and/or kindergarten. For educational or recreational purposes, they make use of many children's goods at these places. Some children's goods contain phthalates and heavy metals with polyvinyl chloride (PVC), so due to their physiological and behavioral characteristics children are exposed to high concentrations of phthalates and heavy metals. This study aims to measure PVC and heavy metals, which are harmful substances in children's goods which can have an effect on children's health. Methods: Six samples of children's goods were selected through cases of detected harmful substances and the results of previous research, including assembly blocks, model toys, household toys, bags, indoor play equipment, and floor mats. The selected items were measured using X-Ray Fluorescence (XRF), and the presence and content of environmentally harmful substances such as PVC or heavy metals in the materials of children's goods were examined. Results: The highest detection rate for PVC was observed in floor mats, and bags and indoor play equipment were higher than other goods in this regard. The highest detection rate for heavy metals was found in bags, followed by indoor play equipment, assembly blocks, household toys, model toys and floor mats. Except for bags containing heavy metals, five goods showed the highest level of Pb compared to other heavy metals. Floor mats contained the highest level of Pb, Cr, and Cu among all goods. Conclusion: Many children's goods contain PVC and heavy metals, and high levels of heavy metals have been detected in some goods. It is necessary to manage children's goods to support their health.

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.