• Title/Summary/Keyword: Indoor Environmental Design

Search Result 230, Processing Time 0.031 seconds

A Basic Study on the Variability of Indoor Spaces for Local Children's Centers - Focused on the Analysis of Design Guideline - (지역아동센터 실내공간 가변방안을 위한 기초연구 - 디자인가이드라인 사례분석을 중심으로 -)

  • Kim, Mi-Young;Moon, Jeong-Min
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.75-82
    • /
    • 2015
  • Although the government has revised the child welfare act, institutionalized the establishment of local children's centers, and given financial support for them, there are a number of problems with respect to their operation. Specifically, one of main problems is their limited space. Diverse problems that go with the arrangement of limited space and usability have occurred, however there are only a few strategies to use limited space flexibly. This study assumed variability as one of the methods to solve spatial problems. As a basic research for the assumption, Analyzing the variable method and characteristics of domestic and foreign child-care facility guidelines was performed trying to take advantage of as a basic data in order to seek a variable scheme of local children centers' indoor space. For this purpose, study analysed the methods and characteristics of variability centering on aspects related to variability which are environmental design elements required by local children's centers as suggested in previous studies. The results are as follows. First, the variability of space should be planned according to activity and time, and consider the methods of division, storage, and other facilities necessary. Second, methods of variability in space can be classified into creating areas and structures that are variable. Third, as a result of analysing the environmental design elements required by local children's centers, this study discovered the following characteristics: multi-purpose usability through a combination of variable devices, transition through a variable space medium and setting up areas and expansion of indoor variability assuming usability through internal and external connections.

Green Design Principles and Techniques of Korean Folk Houses in Rural Area (전통농촌주택의 환경친화성에 관한 연구)

  • Han, Dong-wook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.1 no.2
    • /
    • pp.15-27
    • /
    • 1999
  • The Korean folk house, especially in rural area, has created the comfortable indoor environment with passive control of outdoor climate as environmental architecture. This study aims to identify the peculiar elements of sustainable architecture in folk houses in rural areas of Cheju Island and Ullŭng Island through the field experiments. The elements of environmental control of folk houses in both islands could be developed as the design elements of modern rural architecture. This effort can play major role to find the green design principles and techniques of environmental control of the building which have been neglected in the design of modern architecture.

  • PDF

Design and Development of Remote Monitoring System for Confirmation of Indoor Environment (실내 환경 확인을 위한 원격 모니터링 시스템의 설계 및 개발)

  • Lee, Keonha;Kim, Suyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.5-8
    • /
    • 2019
  • Recently, we have been demanding the comfort of the indoor environment due to environmental problems such as fine dust and yellow dust. In addition it is pursuing the most pleasant indoor environment for humans. In this study, we designed and implemented monitoring systems and mobile applications to enable information such as room temperature and humidity. Open source software and open source hardware are required to design and implement the systems proposed in this study. In this study, the systems implemented used a bluetooth module, a light sensor, and a temperature and humidity sensor. In the future, we expect to be a basic study of systems that can operate dehumidifiers, warm-air fans, fans and humidifiers using motors and optimize indoor environment.

  • PDF

Present Condition of Indoor Noise Level in One-Room Type Multi-Family Housings around Campus (대학주변 원룸형 다가구주택의 실내소음수준 실태)

  • Choi Yoon-Jung
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.3 s.50
    • /
    • pp.191-198
    • /
    • 2005
  • The present study is a preliminary research improving the dwelling quality of one-room type multi-family housings around the university campus. The purpose of the study is to investigate the present condition of Indoor noise level using · residents' responses and field measurements. The respondents are 104 residents living in one-room type multi-family housings. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the $26th\~28th$ of November 2002. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of indoor noise. 2) They answer 'living equipment foise' and 'water hammer' as major types of indoor noise of house unit. 3) Outdoor noise levels, basic factor of noise environment in 6 subject buildings were distributed $52.8\~65.3dB(A)Leq_{5min}$ and were inappropriate to the standard for environmental noise, $55 dB(A)Leq_{5min}$. 4) Indoor noise levels of subject house units were measured as $27.5\~63.5dB(A)Leq_{5min}$, the average of each house unit except one house unit was higher than the level feeling as noise, 40dB(A). 5) It was found that the differences of indoor noise levels between subject house units were caused by 'residents' living noise', 'living equipment noise', 'water hammer', and 'walking and talking noise in stairs and corridors'. 6) Therefore, it is required to plan for improving the quality of noise environment in one-room type multi-family housing around the campus. For example, soundproof construction (including double window with pair glass and balcony), outdoor garden with trees and water for increasing natural sound, interior materials with sound absorbing power to absorb living noise, soundproof pipe or double surface pipe for decreasing 'water hammer', and noiseproof floors, etc. are required.

A Pilot Study of Improving the Atmospheric Environment of Classroom for Students' Learning Activities

  • Kim, Tae-Han;Lee, Hanju;Choi, Boo-Hun;Hyun, Hye Sun
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.2
    • /
    • pp.179-194
    • /
    • 2021
  • Background and objective: Plant-based biofilter system has become a promising candidate for improving indoor air quality due to its eco-friendly and sustainable nature. However, it remains controversial whether indoor air purification using a biofilter is effective. Methods: This study used the one-group pre- and post-test design to analyze the effects of the operation of the plant-based biofilter system on indoor air quality, students' perception of indoor air quality, health effects, and subjective and objective attentiveness. Results: Results of this study show that the application of the plant-based biofilter system changed the air environment in the classroom. The operation of the plant-based biofilter system significantly decreased PM2.5 and PM10 and slightly increased temperature and humidity. Satisfaction with air quality and subjective attentiveness were significantly improved but objective attentiveness and health effects were not improved. Conclusion: Further studies need to be conducted for improving indoor air quality of schools and evaluating the health effects and attention of occupants to present the objective performance of the plant-based biofilter system.

A Farm Scale Study on the Modified Ventilation System for Improving Environmental Factors in a Confined Nursery Pig Building (무창자돈사의 환경요인 개선을 위한 변형환기시스템의 현장 평가 연구)

  • Kim, H.T.;Ko, H.J.;Kim, K.Y.;Nishizu, T.;Choi, H.L.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.175-181
    • /
    • 2006
  • Nursery pig building is imperative to provide environmental conditions favorable to maintenance of piglet health and the efficiency of growth rate. To meet the ultimate goal, it is necessary to apply proper ventilation design and construction to a confinement livestock building. This study was conducted to investigate the performance of a modified ventilation system in terms of devised slot-inlet (modification I) and exhaust fan (modification II) to improve air change rate in a confined nursery pig building, with dimension of 5.9 m(W) ${\times}$ 12.6 m(L) ${\times}$ 2.2 m(H) in an Darby Genetic Station. The experiment was carried out in August, especially when the outdoor peak temperature were above $30^{\circ}C$ and the measured indoor environmental factors were temperature, air velocity, humidity and ammonia concentration which have been known to affect the piglet health and growth. There was no difference in indoor temperature between the original and modified ventilation systems, however the air velocity and ammonia concentration in confined nursery pig building with modified ventilation system were, in most cases, better performance than original ventilation system. Therefore, it was concluded that the slot-inlet system that kept indoor environmental factors pertinent and had an economic advantage, should be considered as a ventilation system for decreasing sensible heat from piglet in confined nursery pig building during extreme summer season.

Design and Implementation of an Indoor Particulate Matter and Noise Monitoring System (실내 미세먼지 및 소음 모니터링 시스템 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • As the COVID-19 pandemic situation worsens, the time spent indoors increases, and the exposure to indoor environmental pollution such as indoor air pollution and noise also increases, causing problems such as deterioration of human health, stress, and discord between neighbors. This paper designs and implements a system that measures and monitors indoor air quality and noise, which are representative evaluation criteria of the indoor environment. The system proposed in this paper consists of a particulate matter measurement subsystem that measures and corrects the concentration of particulate matters to monitor indoor air quality, and a noise measurement subsystem that detects changes in sound and converts it to a sound pressure level. The concentration of indoor particulate matters is measured using a laser-based light scattering method, and an error caused by temperature and humidity is compensated in this paper. For indoor noise measurement, the voltage measured through a microphone is basically measured, Fourier transform is performed to classify it by frequency, and then A-weighting is performed to correct loudness equality. Then, the RMS value is obtained, high-frequency noise is removed by performing time-weighting, and then SPL is obtained. Finally, the equivalent noise level for 1 minute and 5 minutes are calculated to show the indoor noise level. In order to classify noise into direct impact sound and air transmission noise, a piezo vibration sensors is mounted to determine the presence or absence of direct impact transmitted through the wall. For performance evaluation, the error of particulate matter measurement is analyzed through TSI's AM510 instrument. and compare the noise error with CEM's noise measurement system.

Analyzing Therapeutic Design Characteristics in the Indoor Atrium of the Outpatient Areas in Children's Hospitals Overseas (해외 어린이병원 외래진료부의 실내 아트리움에 적용된 치유적 계획특성 분석)

  • Seo, Jae-Yeon;Cho, Min-Jung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.9
    • /
    • pp.65-75
    • /
    • 2019
  • This study aims at analyzing the therapeutic design characteristics implemented in the indoor atriums of the outpatient areas in four children's hospitals in London and San Francisco. A mixed-method approach was used to examine the spatial configurations and design elements in the atriums, while a literature review was conducted to understand the therapeutic design characteristics relevant to atrium spaces and children's healthcare facilities. The spatial design and the pattern of use of the atrium in each hospital were studied during field visits and interviews with the hospital management staff. Based on the literature review and the observations from the field study, a Visibility Graphic Analysis was chosen to examine the visibility, accessibility, and intelligibility of the spatial configurations in the atriums of each hospital. In addition, the openness, restfulness, and vibrant ambience of the design elements in the atriums of each hospital were investigated by surveying fifty-two design professionals on the quality of the design elements in the atriums. A spatial configuration analysis, confirmed that all the atrium spaces had high visibility, accessibility, and intelligibility due to their high connectivity, integration, intelligibility, and because the atriums were laid out in the open lobby space, along the major circulation axis, or in the circulation intersection. In the survey of the design element evaluation, all atriums proved to be appropriate in terms of openness, while the adequacy of restfulness and vibrant ambience differed depending on the hospitals. Notably, location and orientation, access, natural light, outdoor view, and play facilities were found significant environmental design elements determining the successful implementation of the therapeutic design in the atriums. The observations from the aforementioned are further discussed to enhance the therapeutic design quality of atrium spaces in children's hospitals.

A Comparative Study of a Domestic and Foreign Green Architecture Evaluation Items for a Green Performance Enhancement of Hospital Architecture (병원건축의 친환경 성능 향상을 위한 국내외 친환경 건축물 평가항목의 비교 연구)

  • Lee, Ho-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.99-107
    • /
    • 2009
  • In order to prepare future green hospital architecture authentication system, this study is a comparative year report to Korean, the United States, Japanese, British, Canadian and Australian green building authentication systems. Also, the United States and Australian Green hospital authentication systems were examined, and the authentication items of hospitals were compared with those of civil architecture. Though the examination and analysis, the portion of indoor environmental quality section commonly shows the average of 20.7 percent in all 6 countries. Especially, IAQ(Indoor Air Quality) among inside IEQ(Indoor Environment Quality) is overwhelmingly much treated in Korea, the U.S.A, Canada and Australia. In Japan, heat, light and sound are the important factors for authentication evaluation, while in the U.K light are more emphasized for the authentication. 'LEED for Healthcare' as a hospital evaluation authentication system subdivided currently most. The system includes the detailed and extensive evaluation items ranging from hospital management, traffic, emission, water resources utilization to integrated design and furnishing. These overseas systems should be carefully investigated, researched and analyzed for an appropriate improvement of domestic green hospital authentication system. Also the current evaluation method of IEQ section of Korean GBCC needs to be modified. That's why the method puts too much importance on IAQ in IEQ section.

Analysis on Characteristics of Indoor Environment and Satisfaction Level ofUsers of Senior Centers in Jeonju Residential Areas (전주시 단독주택 지역에 위치한 경로당의 실내 환경의 특성과 이용자 만족도에 대한 분석)

  • Jeoong, Insoo;Meng, Xiangwei
    • Journal of the Korean housing association
    • /
    • v.27 no.6
    • /
    • pp.31-43
    • /
    • 2016
  • The purpose of this paper is to gather information and opinions to better guide the direction for implementing improvements of the senior centers' indoor environments located in Jeonju residential areas, by surveying the users about the level of satisfaction and analyzing the result in relation to the current situation. Senior centers located in Jeonju residential areas were operating the facilities with low financial support from the local autonomous entity. According to the results of the survey, most of the users tend to use the facilities between 12p.m. to 6p.m., and the majority have lunch at the senior centers. Most of the senior centers already have cooking facilities, without a dining room, except one place, and even the facilities they have are very poor. In a thermal environment area, the temperature is mostly above in summer or below in winter the appropriate temperature, especially the temperature of the restroom of all senior centers are below $20^{\circ}C$ in winter. The density of carbon dioxide is above average in most indoor areas. However, the users' level of facilities' satisfaction was positive. To improve the seniors' quality of life, the local autonomous entity has to start regular check-ups and repair of the poor indoor environment and facilities, with more financial support and active supervision by senior center the management.