• Title/Summary/Keyword: Indoor Environmental Design

Search Result 230, Processing Time 0.026 seconds

An Empirical Study on Public Child Care Center for the Necessity of the Eco-Environmental Space (친환경공간의 필요성에 따른 구립 어린이집의 사례 연구)

  • Han, Hae-Ryon;Park, Young-Ki
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.91-94
    • /
    • 2007
  • The change of modern society arouse the issue of the family structure and the demand of upbringing. According to the issue, the need of the upbringing is the big interest in society. This study is on the necessity of the eco-environmental space in public child care center. The study progressed with the result of the prior study, the demand of the parents of students in eco-environmental space in child care center. The results of the study are first, the natural light source can import in sky light, side light and atrium in child care center. Second, the indoor garden and interior plants would give the natural feelings. Third, the ponds and waterways in indoor and outdoor would give the empirical experiences. And the last, the stone and clay would give the tender feelings in interior and the sand play in outdoor would give the activities. This study would be the foundation on the upcoming study of the needs of the eco-environmental spaces in child facilities.

  • PDF

A Study on the condition of Indoor environmental safety in kindergarten (유아교육기관의 실내 환경 안전 실태에 관한 연구)

  • Choi, Eun-Jin;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.242-246
    • /
    • 2008
  • This study is to research on the condition of safe environment of kindergartens. This study is to supplement the preceding study which was based only on survey to show the result and analyze the condition and problems of the safety of kindergartens to suggest the basic database of indoor environment that cause accident. First as a theoretical study, we analyze the preceding studies according to the related regulations. And we made checklist based on this and visited and investigated two kindergartens where applied for the case study As the result, we could understand factors that can cause accidents from classroom, corridor, door, stairs, balustrade, toilet, kitchen, front door, and fire exit/shelter. Especially, in case of fire exit/shelter, the whole renewal of kindergarten was necessary which is difficult. But, though it can not be advanced right away, they should try to have facility expansion and repair works gradually. And for more study on this, active cooperation from kindergartens are in need.

  • PDF

A numerical Study for Improvement of Indoor Air Quality of Apartment House (공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.521-530
    • /
    • 2009
  • This study has been made to execute a research in order to lead the improvement of indoor air quality, examining the indoor ventilation characteristics by using a numerical analysis method. To this end an extensive parametric investigation are made according to various external flow variables such as main wind direction and wind speed by season, building layout design, and location of ventilators, etc. in Daedeok Techno Valley, one of large-scaled apartment in Daejeon. It is observed there was a significant difference of main wind direction between summer and winter. The main wind direction in summer was a south wind, and on the contrary the direction in winter is northnorthwest, which is similar to the average main wind direction for 10 years. One of the important calculation results is that the change of wind direction causes a significant effect on the apartment ventilation by the change of pressure difference around each complex of apartment. In case of favorable area of ventilation, the indoor ventilation rate can meet 0.7 ACH from the standard value only with natural ventilation. On the contrary, in other area the value was much lower than the standard value. If the calculation result applies to the design of layout apartment or placement of ventilators, it will be greatly helpful to the energy saving because it can be parallel with the natural ventilation to help securing ventilation rate, not much depending on the mechanical ventilation.

The Study on Concentration of PM10 and Heavy Metal in Public Schools at Chung-Nam Area (충남 지역 일부 학교의 PM10과 중금속 농도에 관한 연구)

  • Son, Bu-Soon;Song, Mi-Ra;Kim, Jung-Duk;Cho, Tae-Jin;Yang, Won-Ho;Chung, Tae-Woong
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.1005-1013
    • /
    • 2008
  • In this study, in order to analyze the air quality of the indoor environments of schools, we measured the indoor, outdoor and personal exposure concentration level of $PM_{10}$ for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003. 1. Old classrooms contained more dust than new classrooms; the average of respirable dust is $43.27\;{\mu}g/m^3$ for new classrooms while $53.38\;{\mu}g/m^3$ for old one. The exposure concentration level of respirable dust in new classrooms were in summer higher outdoors than indoors. The values were indoors $46.71\;{\mu}g/m^3$, outdoors $50.46\;{\mu}g/m^3$, and personal $41.62\;{\mu}g/m^3$. Meanwhile in winter indoors had a higher concentration level than outdoors, the values being indoors $39.11\;{\mu}g/m^3$, outdoors $34.86\;{\mu}g/m^3$, and personal $49.01\;{\mu}g/m^3$. 2. Cr concentration level within dust was slightly higher in summer indoors ($101.50{\pm}32.10\;ng/m^3$) and outdoors ($100.89{\pm}35.18\;ng/m^3$) than winter indoors ($85.80{\pm}48.95\;ng/m^3$) and outdoors ($74.43{\pm}38.93\;ng/m^3$), but in personal concentration level, winter was higher. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. As such, a logical and systematic education program for students about the importance of indoor air quality should be carried out. Also the results of $PM_{10}$ concentration level measurements emphasize the need for regular measurements of indoor / outdoor and personal concentration level. New classrooms in particular needs to be used after measuring pollutants and safety, and requires installation of a ventilation device in all classrooms to improve air quality.

Calculation of the Theoretical Total Amount Ratio of Di(2-ethyl-hexyl) Phthalate in Indoor Air and Floor Dust in a Test House (모의 실험주택 모니터링 결과를 활용한 실내공기 및 바닥먼지 중 Di(2-ethyl-hexyl) phthalate (DEHP)의 이론적 총량 비율 산출)

  • SaHo Chun;Khawon Lee;SeungJung Kim;SeungPyo Jung;DaYoung Kang;Ki-Tae Kim
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.324-333
    • /
    • 2023
  • Background: Human exposure to phthalates in indoor environments occurs via dermal absorption, oral ingestion of indoor dust, and inhalation of indoor air. However, systematic studies to investigate the exposure rate to phthalates among the three exposure routes in indoor environments are currently limited. Objectives: A theoretical exposure ratio between inhalation and oral exposure was calculated based on the total amount of di(2-ethyl-hexyl) phthalate (DEHP) emitted into indoor air and deposited into floor dust in a test house. Methods: Flooring and wallpaper containing DEHP were installed in a test house and the concentration of DEHP in both indoor air and floor dust were monitored for five months. Based on the measured DEHP concentrations, the theoretical total amount ratio of DEHP that could be exposed through inhalation and oral ingestion was calculated. Results: Considering the period of operation in the test house, the theoretical total amount of DEHP through inhalation and oral ingestion exposures in the entire test house space was calculated to be 0.014 mg and 5.5 mg, respectively. The exposure ratio of the two routes between inhalation and oral exposure corresponding to the total DEHP amount in flooring and wallpaper was 6.0×10-7% and 2.3×10-4%, indicating that theoretical oral exposure to DEHP is approximately 380 times higher than inhalation. Conclusions: Monitoring results from a test house has shown that oral exposure is the main exposure route for DEHP in indoor environments. The experimental design employed in this study and theoretical exposure ratio obtained can be applied to investigate actual exposure to DEHP and to determine the exposure characteristics of various types of semi-volatile organic compounds.

A Study on the Design of Planterior to Reduce and Purify Indoor Particle Matters (PM) (실내 미세먼지 저감을 위한 플랜테리어 디자인 연구)

  • Ahn, SeungWon;Jeong, Jun Hyun
    • Journal of the Korean Society of Floral Art and Design
    • /
    • no.44
    • /
    • pp.3-31
    • /
    • 2021
  • To verify the types of effects that plants have in our general living conditions, I examined an air quality in living rooms of the three, 129.78m2 size, apartments that were with and without plants. and the findings of the study were as addressed below. 1) Experiments showed no statistically significant differences in Case A. However, in Case B and Case C, the standard deviation of PM10, PM2.5 and PM 1.0 verified that each had statistically significant (p<.01) differences. 2) It is believed that the effect of reducing particle matters due to the installation of plants in the indoor space is to vary significantly depending on the indoor environmental conditions, the cleanliness of the room, and the amount of furniture and may also differ depending on the daily dietary cooking method. In addition, it is believed that the planterior will not only reduce indoor fine dust, but also reduce the psychological comfort and eye fatigue of the residents. Nevertheless, supplementary research is needed. 3) In the planterior design for reducing indoor particle matters, various measures were examined. Among them, the vertical wall design method was tested and suggested through empirical experiments. In addition, maintenance methods were proposed depending on the type of indoor plant.

Analysis of Differences in Indoor Environment and Fatigue Response According to Ventilation in Lecture Hall (대형강의실의 환기여부에 따른 실내환경과 피로감 반응의 차이분석)

  • Oh, Ye-Seul;Hwang, Jin-A;Choi, Yoon-Jung
    • Korean Journal of Human Ecology
    • /
    • v.19 no.2
    • /
    • pp.417-428
    • /
    • 2010
  • The purpose of this study was to analyze differences of the indoor environment and student's fatigue response according to ventilation in university lecture hall. The experiments consisted of measuring the indoor environmental parameters and a survey of student's responses. The experiments were in the lecture hall that the actual lecture was conducted in on the $25^{th}$ of May 2009 (not opening windows and door- A) and the $1^{st}$ of June 2009 (opening windows and door- B). The experimental variable was ventilation by opening the windows and door, and the controlled conditions were indoor temperature by air conditioner, volume of the microphone and VTR, lighting conditions and teaching method. The results are as follows: 1) The indoor temperature was maintained in controlling A, B but the $CO_2$ and relative humidity of A (average 3579ppm, 62.6%) was higher than B (average 1697ppm, 48.1%). 2) There were differences in the student's subjective responses and student's fatigue responses between A and B. 3) Therefore, it was found that ventilation by opening the windows and door was a valid way to improve the relative humidity and to reduce $CO_2$ in the lecture hall.

Evaluation of Indoor Environment Characteristics through Field Measurement in Large-sized Discount Stores (현장측정을 통한 대형 할인매장의 실내환경 평가)

  • Park Byung-Yoon;Jung Yong-Ho;Ham Heung Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.863-872
    • /
    • 2005
  • It is important to control indoor environment for influence on health and comfort of occupants in large-sized discount stores. On the other hand large-sized discount stores have a large number of visitors, vestibules, open spaces, high energy consumption and increasing of outside air intake. This study aims to offer the design data of building services system that can save energy and control environment through field measurement selecting two large-sized discount stores. Indoor environment factors such as temperature, relative humidity, air velocity and concentrations of $CO_2$, CO gas and TSP were measured and evaluated. In each case of $CO_2$, and CO gas, its maximum values were 2,800 ppm and 20 ppm. So proper strategy for the indoor air quality is indispensable in this type of building. Dry bulb temperature varies from $18^{\circ}C$ to $28^{\circ}C$ according to a measuring point and time. From this results, it is inferred these buildings had excessive equipment capacity. In terms of economical and environmental points, these data will be utilized to the design of HVAC system of retail facilities.

Critical Factor on Selection Indoor Air Quality improving alternatives for healthcare projects (병원의 실내 공기 질 솔루션 선택에 영향을 미치는 요인들)

  • Dang Nguyen-Hong Anh;Ahn, Yong-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.63-64
    • /
    • 2023
  • Indoor Air Quality is crucial in hospital projects to ensure the health and safety of patients, staff, and visitors. The research methodology comprises an comprehensive literature review, then a comprehensive questionnaire survey conducted among stakeholders involved in Vietnamese hospital projects. 15 variables were identified and categorized into four distinct groups, elucidating their influence on the adoption of advanced IAQ-enhancing technology. This study uses factor analysis, a mean score method and hypothesis test to analyze the factor result from the survey. two-step process, including an in-depth literature review and questionaire survey. The study's findings culminated in the ranking, examination, and categorization of these 15 variables, which were clustered into four essential categories: economic factors, design elements, governance strategies, and technical requirements. Additionally, the research explored viable solutions to improve indoor air quality in Vietnam's unique environmental context, examining the factors that impact the selection of such solutions. The study's outcomes yield practical recommendations for architects, engineers, and hospital administrators in enhancing IAQ within healthcare facilities. Furthermore, it presents a framework attuned to local environmental factors and building materials, contributing significantly to the existing body of knowledge on IAQ within hospital projects, particularly in the Vietnamese context.

  • PDF

A Study on the Improvement of Comfortable Living Environment by Using real-time Sensors

  • KIM, Chang-Mo;KIM, Ik-Soo;SHIN, Deok-Young;LEE, Hee-Sun;KWON, Seung-Mi;SHIN, Jin-Ho;SHIN, YongSeung
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.4
    • /
    • pp.19-31
    • /
    • 2022
  • Purpose: This study was conducted to identify indoor air quality in various living spaces using sensors that can measure noise, vibration, fine dust, and odor in real time and to propose optimal indoor air quality maintenance management using Internet of Things(IoT). Research design, data and methodology: Using real-time sensors to monitor physical factors and environmental air pollutants that affect the comfort of the residential environment, Noise, Vibration, Atmospheric Pressure, Blue Light, Formaldehyde, Hydrogen Sulfide, Illumination, Temperature, Ozone, PM10, Aldehyde, Amine, LVOCs and TVOCs were measured. It were measured every 1 seconds from 4 offices and 4 stores on a small scale from November 2018 to January 2019. Results: The difference between illuminance and blue light for each measuring point was found to depend on lighting time, and the ratio of blue light in total illumination was 0.358 ~ 0.393. Formaldehyde and hydrogen sulphide were found to be higher than those that temporarily attract people in an indoor office space that is constantly active, requiring office air ventilation. The noise was found to be 50dB higher than the office WHO recommendation noise level of 35 ~ 40dB. The most important factors for indoor environmental quality were temperature> humidity> illumination> blue light in turn. Conclusions: Various factors that determine the comfort of indoor living space can be measured with real-time sensors. Further, it is judged that the use of IoT can help maintain indoor air quality comfortably.