• 제목/요약/키워드: Indoor Airflow Distribution

검색결과 14건 처리시간 0.018초

The Impact of Double-Skin Façades on Indoor Airflow in Naturally Ventilated Tall Office Buildings

  • Yohan, Kim;Mahjoub M. Elnimeiri;Raymond J. Clark
    • 국제초고층학회논문집
    • /
    • 제12권2호
    • /
    • pp.129-136
    • /
    • 2023
  • Natural ventilation has proven to be an effective passive strategy in improving energy efficiency and providing healthy environments. However, such a strategy has not been commonly adopted to tall office buildings that traditionally rely on single-skin façades (SSFs), due to the high wind pressure that creates excessive air velocities and occupant discomfort at upper floors. Double-skin façades (DSFs) can provide an opportunity to facilitate natural ventilation in tall office buildings, as the fundamental components such as the additional skin and openings create a buffer to regulate the direct impact of wind pressure and the airflow around the buildings. This study investigates the impact of modified multi-story type DSFs on indoor airflow in a 60-story, 780-foot (238 m) naturally ventilated tall office building under isothermal conditions. Thus, the performance of wind effect related components was assessed based on the criteria (e.g., air velocity and airflow distribution), particularly with respect to opening size. Computational fluid dynamics (CFD) was utilized to simulate outdoor airflow around the tall office building, and indoor airflow at multiple heights in case of various DSF opening configurations. The simulation results indicate that the outer skin opening is the more influential parameter than the inner skin opening on the indoor airflow behavior. On the other hand, the variations of inner skin opening size help improve the indoor airflow with respect to the desired air velocity and airflow distribution. Despite some vortexes observed in the indoor spaces, cross ventilation can occur as positive pressure on the windward side and negative pressure on the other sides generate productive pressure differential. The results also demonstrate that DSFs with smaller openings suitably reduce not only the impact of wind pressure, but also the concentration of high air velocity near the windows on the windward side, compared to SSFs. Further insight on indoor airflow behaviors depending on DSF opening configurations leads to a better understanding of the DSF design strategies for effective natural ventilation in tall office buildings.

돔경기장의 공조방식에 따른 겨울철 열환경 분석 (The Analysis of Indoor Thermal Environment for Air Condition System in Dome Stadium)

  • 석호태;양정훈;채문병
    • 한국공간구조학회논문집
    • /
    • 제9권2호
    • /
    • pp.53-63
    • /
    • 2009
  • 본 연구에서는 국내 돔경기장을 해석대상공간으로 선정하여 기존 공조방식과 국외 돔경기장에서 사용한 공조방식을 적용하여 겨울철 실내기류 및 온도분포를 분석하고, 열고온층을 해소하기 위한 방안으로 설치된 기류유인팬의 적절성을 검토하였다.

  • PDF

대형 강의실의 실내 열환경 실측 및 컴퓨터시뮬레이션 비교 연구 (Field Measurements and CFD Simulations of Indoor Thermal Environments in the Assembly Hall)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.179-186
    • /
    • 2004
  • The evaluation of the indoor environment of the Assembly Hall in the University, which is designed to be a large space, requires efficient design of its heating system that takes into consideration natural convection and the characteristics of the occupant's spaces. Indoor thermal environment was measured in the field and simulated with CFD code. The estimations of temperature distribution and indoor airflow distribution must be carried out simultaneously, as the thermal stratification is induced by natural convection flows. In order to simulate the even distribution of factors affecting the indoor environment, including temperature and airflow, Phoenics is used. The turbulent flow model adopted is the RNG k- model. The inlets and outlets of the air-conditioning systems, material and thermal properties, and the size of the test room ($35m{\times}18m{\times}10m$) are used for the simulation. Since the Assembly Hall is symmetric, half of the space is simulated. A Cartesian grid is used for calculation and the number of grids are respectively $60{\times}45{\times}35$. The results of the computer simulation during winter conditions are compared with the measurements at the typical points in the assembly hall with the heating system. After evaluating the results of the computer simulations, the methods of the heating system and layout are suggested.

돔경기장의 급배기방식에 따른 기류분포 및 실내온도 특성 (The Characteristics of Indoor Temperature and Airflow Distribution for Air Supply and Return System in Dome Stadium)

  • 채문병;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.434-439
    • /
    • 2008
  • Dome stadiums give thermal unpleasant feeling to occupants because of the radiant heat and the indoor and outdoor haet exchange from roogs or lightweight building envelopes of sidewalls. This study analyzed the indoor temperature and velocity distribution according to various air supply and return sustems in dome stadiums in summer.

  • PDF

매크로 모델에 의한 실내온열환경 검토 (An Analysis of Indoor Thermal Environment by Macro Model)

  • 정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.584-589
    • /
    • 2008
  • It is known that slab thermal storage which uses concrete slab as thermal material is effective in the load leveling and using the nighttime electric power. The temperature distribution is not constant in plenum in thermal storage time by beams, ducts such as several factor. It is considered that this fact will effect on efficiency of thermal storage and indoor thermal environment. The purpose of this paper is to examine the thermal environment inside plenum. A macro model was made for the analysis of indoor thermal environment as the first step. The flow rate distribution and temperature distribution of object room model was examined by use of basic equations such as airflow by the pressure difference between unit cells, heat flow by air and heat transfer.

  • PDF

전열교환기의 세대내 풍량 분배를 위한 CFD를 이용한 최적설계방안 (Optimal Design for Airflow Distribution of Total Heat Exchanger in House Using CFD)

  • 김진호;송난정;이건태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.701-705
    • /
    • 2009
  • After revision of law of architecture in 2006, all houses which have more 100 households must has ventilation unit for the indoor air quality. Optimal design of the natural and the mechanical ventilation has being considered. In this paper, it is carried out about optimal design for airflow distribution of total heat exchanger in houses using CFD. As the result, first design of ventilation has some problem in porch area. Adding diffusers in porch area and changing diffuser schedule make more efficient ventilation than original design.

  • PDF

생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석 (Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory)

  • 황지현;홍진관
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.

외부바람과 연돌효과의 상호작용에 의한 고층주거 건물의 연간 침기량 분포 (The annual infiltration distribution caused by wind and stack effects in high-rise residential buildings)

  • 박주현;윤성민;송두삼;김용식
    • 도시과학
    • /
    • 제8권1호
    • /
    • pp.25-31
    • /
    • 2019
  • Infiltration affects indoor environmental and air quality and energy consumptions in buildings. Especially, airflow and the infiltration are more remarkable in high-rise buildings due to the air-driving forces (stack and wind effects). Thus, it is important to understand infiltration distributions in high-rise residential buildings. In this study, the weather-driven infiltration is characterized from the viewpoint of interactions between external wind and stack effect in high-rise residential buildings. To calculate accurately the annual infiltration distributions, this study also suggests an airflow and thermal simulation method with a two-step calibration of air-leakage data. The simulated results show (1) how the interaction between stack and wind effects induce infiltration types (outdoor and interzone air infiltration) and (2) how much the interzone air infiltration (being ignored in previous studies) occurs due to the stack effect, as well as the outdoor air infiltration rates.

탑상형 아파트의 여름철 통풍성능 개선에 대한 연구 (A Study on the Improvement of Cross Ventilation Efficiency in a Tower Type Apartment in Summer Season)

  • 조근제;장현재
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.299-304
    • /
    • 2012
  • In terms of plane structure, tower-type apartments have several disadvantages compared to flat-type apartments in the aspect of ventilation rate. Such disadvantages may not produce good indoor cooling effects with natural ventilation inside the heated apartments in hot summer days, so they may cause high energy consumption by an increase in cooling load. The purpose of this study is to investigate ways for improving the indoor thermal environment of tower-type apartments in summer by conducting quantitative evaluations of the airflow distribution in households.

  • PDF

PFT법에 의한 수직적 3 ZONE 분할 조건에서의 환기량 측정 (Ventilation Measurement with PFT in Three-storied Detached House)

  • 김훈
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.506-515
    • /
    • 2013
  • The PFT (PerFluorocarbon Tracergas Technique) is of advantage to field surveys for evaluating the ventilation condition, due to its simplicity and convenience. On the other hand, it requires researchers to make some additional considerations that include uncertainties, such as the substance concentration distribution in indoor air, representativeness of a sampler, deviation of emission sources, and analysis error. In this study, the PFT and $CO_2$ tracer gas methods were applied simultaneously, to evaluate the accuracy of PFT on six ventilation conditions in the three-storied detached house. The air exchange and the outdoor air introduction a between and into zones were measured. As the results, deviations of PFT concentration distributions were observed at a sufficiently low level for an accurate determination for a house where the interior height was large, and there were relatively many partition walls. However, when a uniform airflow appeared in the indoor air, it was also validated that the indoor air would be exhausted without sufficient mixing, and consequently the measurement error of the PFT would be large.