• Title/Summary/Keyword: Indoor Air Flow

검색결과 270건 처리시간 0.029초

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

해수 열원 및 폐열 이용 고성능 열펌프 시스템 모사 (Simulation for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy)

  • 최광일;오종택;오후규
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.59-66
    • /
    • 2003
  • The purpose of this study is to analyze the characteristics (COP) of the heat pump system for various operating conditions with the use of seawater heat source and exhaust energy. To accomplish the goal, first of all, the computer simulation for heat pump system is carried out. The heat pump system model is made of a waste heat recovery system and a vapor compression refrigeration system, and the working fluid is R-22. The model calculated the change of COP with the variation of temperature and flow rate. The COP and the plate heat exchanger (PHE) area of the heat pump system are considered moderately high in the condensation temperature of $25^{\circ}^C$ and the evaporation temperature of $2^{\circ}^C$ in indoor culture system. The simulation results will be used effectively for the design and the performance prediction of heat pump system using unused energy in a land base aquaculture system.

배기열회수 알루미늄 열교환기의 공조시스템 적용에 관한 연구 (The Study on the Application of Heat Recovery Aluminium Heat Exchanger in HVAC System)

  • 박용효;김동규;김근오;정용환;금종수;정석권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1272-1276
    • /
    • 2009
  • The purpose of this study is to introduce wasted heat recovery heat exchanger for different kind of material in HVAC systems in field. For the purpose of estimating the large volume rotary heat exchanger and cross flow plate heat exchanger in heat recovery ventilator.

  • PDF

온돌 실내공간의 온도제어 (Temperature Control of Ondol Indoor-Space)

  • 신찬배;이재원;사종엽;이상천;조성환;서항석
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.538-545
    • /
    • 1995
  • The heat transfer model of ondol heating system is derived in the linear form. The step responses of On-Off controller, PID controller and Position type fuzzy controllers are compared in the sense of several aspects : variation of temperature feedback variable, variation of supplied heat quantity by the boiler, variation of flow rate, variation of thickness of the base, variation of the outdoor temperature.

  • PDF

대규모 실내경기장의 성능위주 방재계획에 관한 연구 (A Study on Perfomance Based Evacuation Plan for a Large Indoor-Arena)

  • 최용석;김형근;이규일
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.687-698
    • /
    • 2011
  • In this study, it was analyzed by a numerical analysis that plan/design considerations for ensuring the spectator safety of large arena audiences in a fire emergency evacuation plan. The latest issue, the 'performance-based design', fire and evacuation plan is important. But nowadays 'Specification-based design' is in common. In evacuation simulation, congestion of exit and aisle is ignored because only evacuation time of large-space is mainly analyzed. In smoke flow,'smoke filling effect' tends to be overrated. From now on, when design a field house, it is needed not 'smoke filling effect' and 'large-space evacuation' analysis, but analyzing 'whole building evacuation time' for ensuring fire evacuation safety of spectator.

CFD해석에 의한 침실 호흡역의 환기효율 분석 (Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room)

  • 유복희;윤정숙
    • KIEAE Journal
    • /
    • 제2권3호
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

분리형 에어컨의 실내기 냉매 소음 저감 분석 (Analyzing for Refrigerant Induced Noise for Split type Air Conditioner Indoor Unit)

  • 한형석;시게오 아오야마;모진용;이재권;송용재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.421-426
    • /
    • 2005
  • For the air-conditioner, refrigerant induced noise and vibration should be the problem when it reduced airflow rate in order to reduce the noise at low mode. With the test, it could be verified that one of the main reason for refrigerant induced noise were the velocity and flowing induced force of the refrigerant at the inlet of evaporator. So in order to reduce this velocity with same mass flow rate of refrigerant, quality at the evaporator inlet should be minimized. And in order to reduce flowing induced force of the refrigerant, flowing direction change should be eliminated. So in this paper, it would like to review the characteristics of refrigerating cycle at first and find how the quality and flowing induced force can be minimized.

  • PDF

이산화티탄이 함유된 레드머드를 혼입한 초고성능콘크리트의 배합에 관한 연구 (A Study on the Mixing of Ultra High Performance Concrete with Red Mud containing Titan dioxide)

  • 서승훈;권시원;오상근;김병일
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.70-71
    • /
    • 2019
  • Interest in indoor air quality is increasing day by day due to various reasons such as industrial development. Because redmud, an industrial subsidiary, contains titanium dioxide, this study evaluated self-consolidation performance with Slump Flow Test, J-Ring Test, and L-Box Test by mixing redmud in a mixture of ultra-high performance concrete, and sought the optimal combination with high flowability. In addition, the UHPC mixing experiment with photocatalyst was conducted, and the photocatalyst was replaced by the weight ratio of cement and the redmud by the weight ratio of fine aggregate and mixed with the concrete mixture.

  • PDF

A Study on the Peak Separation of Acetone and Acrolein Based on High-Performance Liquid Chromatography (HPLC) Method

  • Kim, Shin-Do;Kim, Chang-Hwan;Park, Jin-Su;Lee, Jeong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권9호
    • /
    • pp.2011-2016
    • /
    • 2009
  • To resolve the differentiation problem of acetone and acrolein in the analysis of carbonyls by high-performance liquid chromatography (HPLC), we investigated the optimum analytical conditions for their separation. Carbonyl compounds were collected by 2,4-dinitrophenylhydrazine (DNPH)-coated cartridges. We examined the influence of three experimental variables: temperature (25, 30, 40, 50 and 60 ${^{\circ}C}$), flow rate (1.0 and 1.2 mL/min), and relative mobile phase composition (among acetonitrile, water and tetrahydrofuran). The experimental results revealed the optimum analytical condition of a flow rate of 1.2 mL/min, temperature of 32 ${^{\circ}C}$ and mobile phase composition of acetonitrile: water: tetrahydrofuran = 34 : 52.8 : 13.2. The analysis of indoor air composition indicated that acrolein and acetone comprised 11% and 42% of all aldehydes, respectively.

유동 저항에 따른 원심홴의 선정 (Selection of Centrifugal Fan for Flows with Down-Stream Resistance)

  • 김재원;장동희;안은영
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.44-48
    • /
    • 2006
  • Comprehensive experimental works are carried out for the optimal design of a centrifugal blower adopted in an indoor unit of an air-conditioner. The models for consideration are typical multi-blade turbo blower and limit loaded one, respectively. The main interest lies on the fluid dynamics performance when the blower Is installed in the practical system. The methodologies are an experimental estimations with a wind tunnel for blower performance and PIV measurement for the detail flow information. A centrifugal blower with limit loaded fan shows pronounced performances in terms of the flow rate and static pressure rise and the reason is explained by the precise measurement of the flows between blades using PIV. Consequently, it is found that the blower is proper for the flows with a resistance in down stream such as a heat exchanger.