• Title/Summary/Keyword: Indoor Air Flow

Search Result 270, Processing Time 0.029 seconds

Experimental Study on Indoor Thermal Environment of an Office Building During Cool ing Season (실내 열환경에 관한 실측조사 연구 -냉방기 사무소건물을 중심으로-)

  • Kim, Sung-Wan;Jang, Hai-Jin;Park, Sang-Dong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.3
    • /
    • pp.189-197
    • /
    • 1983
  • In this study, the thermal environment of a certain building was investigated by using of concerned equipments and enquete sheets. The measured items were temperature, humidity, air flow and radiant heat, and thermal responses for the occupants were checked also, which are oriented to be used as basic data for environmental design. The results of this study are as followed. 1. The optimal room temperature was $24\~26.5^{\circ}C$ DBT in cooling season. 2. Under the condition from $50\%\;to\;70\%$ of relative humidity, the difference of relative humidity did not impact upon the feeling temperature. 3. In cooling season, the average clothing factor of occupants was 0.34 clo ; 0.49 clo for men and 0.25 clo for women. 4. The average working factor of occupants was $1.1\~1.3\;Met$ in that cooling season.

  • PDF

A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System (실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구)

  • Koo, Jeong-Hwan;Kim, Seong-Chan;Kim, Jang-Woo;Lee, Ju-Yong;Lee, Jae-Keun;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

Development of mass aerosol particle generator and fabrication of commercial anti-viral air filter (대용량 입자 발생 장치 개발 및 이를 이용한 항바이러스 공조용 공기필터 제조)

  • Park, Dae Hoon;Joe, Yun Haeng;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.151-159
    • /
    • 2016
  • Since airborne viruses have been known to aggravate indoor air quality, studies on development of anti-viral air filter increase recently. In this study, a mass aerosol particle generator for coating a commercial air filter (over $300{\times}300mm^2$) was built, and evaluated by comparing a commercial particle generator. Then, via this device, a commercial air filter was coated with anti-viral material ($SiO_2-Ag$ nanoparticles in this study), so fabrication of commercial anti-viral air filter was performed and the pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. The result showed that the particle generation of the new generator was more than about 8.5 times over which of the commercial one. Consequently, $SiO_2-Ag$ particle coating on a filter does not have significant effects on the filtration efficiency and pressure drop with different areas, and the average anti-viral efficiency of the $SiO_2-Ag$ filter was about 92% when the coating areal density was $1.0{\times}10^{12}particles/m^2$.

Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD (CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측)

  • Son, Jeong-Eun;Yu, Byeong-Ho;Pang, Seung-Ki;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

Pre-study for the improvement of air filtration performance in the air handling unit of subway station (도시철도 지하역사 공기조화기의 미세먼지 저감성능 개선을 위한 사전연구)

  • Kang, Joong-Goo;Shin, Chang-Heon;Bae, Sung-Joon;Kwon, Soon-Bark;Kim, Se-Young;Han, Seok-Yoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.541-545
    • /
    • 2008
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator re used in the air handling unit (AHU) of subway station. However, those systems are faced to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts is malfunctioned due to the high load of particulates and the filter material needs periodic replacement. In this study, we surveyed the particle removal systems in order to develop the new system of particle removing can be adopted in the current AHU of subway station.

  • PDF

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

A study on the Development of Vertical Air Temperature Distribution Model in Atrium (아트리움의 수직온도 분포해석 프로그램의 개발에 관한 연구)

  • Kim, Y.I.;Cho, K.H.;Kim, K.W.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.3-11
    • /
    • 1997
  • Recently the construction of atrium buildings has increased but along with it many problems in thermal environment have arised. since the exterior wall of glass, indoor temperature is greatly influenced by weather conditions and since the space volume is very large, the vertical air temperature is not uniform. So, in this study, a Vertical Temperature Distribution Model was developed to predict the vertical air temperature of an atrium and evaluate the effects of the design parameters on the air temperature distribution of an atrium. To consider the characteristics of the vertical air temperature distribution in an atrium, the Satosh Togari's Macroscopic Model was used basically for the calculation of the vertical air temperature distribution in large space and the solar radiation analysis model and natural ventilation analysis model in atrium. And to calculate the unsteady-state inside wall surface temperature(boundary condition), the finite difference method was used. For the verification of the developed temperature distribution program, numerical evaluation of air flow by the ${\kappa}-{\varepsilon}$ turbulence model and in-situ test was conducted in parallel. The results of this study, the developed temperature distribution program was seen to predict the thermal condition of the atrium very accurately.

  • PDF

An Experimental Study of the Air-side Particulate Fouling of Finned-Tube Heat Exchangers of Air Conditioners by using Accelerated Particle-Loading System (파울링 형성 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 실험적 연구)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱;옥주호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.802-808
    • /
    • 2003
  • The air-side particulate fouling of the HVAC heat exchangers degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. The purpose of this study is to investigate the fouling characteristics using accelerated particle loading system. The fouling characteristics are analyzed as functions of a dust concentration, a face velocity and a wet or dry surface condition. The pressure drop increases with increasing test operation and reaches constant asymptotic level. For the saturated condition due to particle loading, the pressure drop across the slitted finned-tube heat exchangers at the face velocity of 1 m/sec increases up to 57% and the cooling capacity decreases about 2%. The cooling capacities are not affected greatly by the presence of the fouling deposits if the thickness of the fouling deposits can not change substantially the flow pattern through the fins.

A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Winter - Without Heat Loads from Occupancy - (대규모 실내경기장의 동계 온열환경 특성 실측조사 - 인체부하 미고려 조건 -)

  • Choi, Dong-Ho;Jeong, Seong-Jin;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.67-77
    • /
    • 2007
  • The purpose of this study is to provide fundamental heating design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with and without heating the space in winter. Heating loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF