• Title/Summary/Keyword: Indoor Air

Search Result 2,357, Processing Time 0.028 seconds

Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space (주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가)

  • Seok, Ho-Tae;Kim, Dong-Woo;Yang, Jeong-Hoon
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.

Study on Indoor Thermal Environment Controlled by Portable Cooler (실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토)

  • Choi, Dong-Kyun;Song, Doosam;Kim, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

A Simulation Method for Considering the Outdoor Wind-Pressure in Calculation of Indoor Air-Flow in High-Rise Buildings (건물 내 공기유동 해석에 외부 바람이 미치는 영향의 분석)

  • Kim, Dae-Young;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.55-62
    • /
    • 2016
  • The air flows in building caused by thermal buoyancy, known as the stack effect, have a pronounced influence on both the indoor environment (thermal environment, noise, draught and contaminant diffusion) and energy needs in high-rise buildings. Prior studies for airflow in high-rise buildings were focused on the degree of stack effect and countermeasures. The wind pressure was neglected during the calculation of the indoor airflow in high-rise buildings to clarify the effect of thermal buoyancy in previous studies. However, wind is an important driving force of indoor airflows in buildings with the stack effect. In this study, the effect of wind pressure on indoor airflow in high-rise building when the stack effect is dominant in winter was analyzed. In this paper, methods that involved considering the wind pressure in airflow network simulation were analyzed.

Visualization of the Comparison between Airborne Dust Concentration Data of Indoor Rooms on a Building Model (실내 공간별 미세먼지농도 비교 데이터의 시각화)

  • Lee, Sangik;Lee, Jin-Kook
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.55-62
    • /
    • 2015
  • The international concern on the inhalable fine dust is continuing to increase. In addition to the toxic properties of the fine dust itself, it can be more dangerous than other environmental factors since the dust pollution is hard to be detected by human sense. Although the information on outdoor air condition can be acquired easily, the indoor dust concentration is another problem because the indoor air condition is influenced by the architectural environment and human activity. It means occupants may be exposed to indoor dust pollution over a long period without being aware. Therefore the indoor dust concentration should be measured separately and visualized as an intuitive information. By visualizing, the indoor dust concentration in each space can be recognized practically in compare with the degree of pollution in adjacent spaces. Besides the visualization outcome can be used as base data for related research such as an analysis of the relation between indoor dust concentration and architectural environment. Meanwhile, with the development of network and micro sensing devices, it became possible to collect wide range of indoor environment data. In this regards, this paper suggests a system for visualization of indoor dust concentration and demonstrates it on an actual space.

Development of an IAQ Index for Indoor Garden Based IoT Applications for Residents' Health Management (실내거주자 건강 관리를 위한 IoT기반 실내정원용 IAQ지수 개발)

  • Lee, Jeong-Hun;An, Sun-Min;Kwak, Min-Jung;Kim, Kwang Jin;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.421-432
    • /
    • 2018
  • Objectives: In this study, we started to develop an indoor garden integrated IoT solution based on IAQ (indoor air quality) and interconnection with an environmental database for smart management of indoor gardens. The purpose of this study was to develop and apply an integrated solution for customized air purification from an indoor garden through big data analysis using IoT technology. Methods: An IoT-based IAQ monitoring system was established in three households within a new apartment building. Based on real-time and long-term data collected, $PM_{2.5}$, $CO_2$, temperature, and humidity changes were compared to those of indoor garden applications and the analyzed results were indexed. Results As a result of the installation, all three households had no results exceeding the standard for indoor air pollution on average $PM_{2.5}$ and $CO_2$ indices. In the case of indoor garden installation, the IAQ index increased to the "Good" section after the installation, and readings in the "Bad" section shown before the installation disappeared. The comfort index also did not dip into the "Uncomfortable" section, where it had been preinstallation, and significantly lowered the average score from "Uncomfortable for sensitive groups" to "Good". Overall, the IAQ composite index for the generation of installations decreased the "Good" interval, but "Bad" did not appear. Conclusions In this study on developing an integrated solution for IAQ based on IoT indoor gardens, big data was analyzed to determine IAQ and comfort indexes and an IAQ composite index. Through this process, it became understood that it is necessary to monitor IAQ based on IoT.

Particulate Matters($PM_{10}$ and Particle-Bound Polycyclic Aromatic Hydrocarbons(PAHs) in Indoor and Outdoor Air in New and Sick Houses

  • Moon, Kyong-Whan;Byeon, Sang-Hoon;Choi, Dal-Woong;Lee, Jang-Hee;Kim, Young-Whan
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.315-318
    • /
    • 2005
  • $PM_{10}$ and 16 PAHs were measured in indoor and outdoor air of 5 different old houses, new and sick houses, respectively. $PM_{10}$ concentrations measured in indoor of three different kinds of houses ranged from 23 to 43 ${\mu}g/m^3$ and in outdoor ranged in 40-64 ${\mu}g/m^3$. Sum of average concentrations of PAHs in old, new and sick houses indoor air were 3.7 $ng/m^3$, 6.6 $ng/m^3$ and 16.1 $ng/m^3$, respectively, which were lower than those of outdoors. Most of the indoor/outdoor ratio for PAHs in each house were less than 1.0 and significant correlation(p<0.05) between indoor and outdoor samples was observed.

  • PDF

Benzo(a) pyrene Level in Indoor Environment due to the Use of Unvented Heating Facilities (煖房器具를 사용하는 室內空氣중의 벤조(a) 피렌 成分濃度에 관한 硏究)

  • 董宗仁
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.1
    • /
    • pp.65-73
    • /
    • 1987
  • Indoor air pollution problems, in fact, have been neglected due to the unawareness of its seriousness and the lack of accumulated data. Recently, some movement of research and regulations, however, have been made for several indoor air pollutants. In this study, one of the carcinogenic polynuclear aromatic hyrocarbon, Benzo(a) pyrene in indoor airborne particulate, was measured and analyzed to estimate emission strength of BaP from an unvented kerosene heater and to know its level in indoor environment with use of a kerosene heater and a wood-burning fireplace. By the measurement of BaP level in a dark room with air exchange rate of app. 3.0, BaP emission strength of a kerosene heater (11,000Btu/hr) was estimated to be 326.6ng/hr (or 29.7 ng/$10^3$ Btu). With 4-hr operation a day of the kerosene heater in an apartment, the BaP level became 2.97ng/m$^3$ from 0.27ng/m$^3$ of background level. The operation of a wood-burning fireplace app. 2hr a day, on the other hand, increased the BaP level from 0.16ng/m$^3$ of background to 3.53ng/m$^3$. So proper ventilation must be considered seriously when unvented heating facilities are used in indoor environment.

  • PDF

Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows (초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교)

  • Choi, Tae-Hwoan;Jeon, Mi-Sook;Lee, Jung-Hyun;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF