• 제목/요약/키워드: Indoor Air

검색결과 2,362건 처리시간 0.03초

항공기 내 실내공기질에 관한 고찰: 이동의 증가와 건강에 미치는 영향 및 블리드에어의 영향 (Indoor Air Quality in Aircraft: The Impact of Increased Mobility and Health Effects and the Influence of Bleed Air)

  • 함승헌
    • 한국환경보건학회지
    • /
    • 제49권3호
    • /
    • pp.129-133
    • /
    • 2023
  • Background: With the rise in global mobility, aircraft indoor air quality has become a significant public health concern. This study focuses on the health implications of increased travel and bleed air-air drawn from aircraft engines for cabin pressurization and air conditioning. Objectives: This research aims to review the potential health effects related to exposure to aircraft cabin air, particularly the effects of bleed air during fume events. Methods: We conducted a literature review of existing studies on aircraft cabin air quality. We focused on both the immediate and health effects of exposure to cabin air, particularly those related to bleed air contaminants. Results: The review found a possible link between exposure to aircraft cabin air and certain health issues, especially in cabin crew and frequent flyers. There was an increased incidence of respiratory and neurological symptoms related to bleed air exposure. However, the cumulative health effects of frequent air travel remain inconclusive due to limited data. Conclusions: This study highlights the need for improving air quality in aircraft to protect public health. While further research is needed to understand the cumulative effects of frequent air travel, the reduction of exposure to bleed air contaminants should be a priority. These findings underline the need for regulatory changes and technological improvements in aircraft cabin air quality.

보육시설의 $PM_{10}$, $CO_2$ 농도와 보육교사의 실내 공기질 인식에 관한 연구 (A Study on $PM_{10}$, $CO_2$ Concentrations in Child Daycare Centers and Teachers' Awareness of Indoor Air Quality)

  • 이지은;최병선
    • 한국학교보건학회지
    • /
    • 제23권1호
    • /
    • pp.29-40
    • /
    • 2010
  • Purpose: The purposes of this study were: (a) to assess indoor air quality such as $PM_{10}$, $CO_2$ concentrations in child daycare centers, (b) to compare the levels with each standard, and (c) to identify teachers' awareness of indoor air quality in child care centers. Methods: Data were obtained from seventeen child daycare centers and ninety-eight teachers in a district of Seoul, from April 3 to May 12, 2009. Collected data were analyzed by SAS 8.2, and descriptive statistics, $x^2$ test, student t-test, Pearson correlation analysis, and Spearman rank correlation were used. Results: The mean of $PM_{10}$ and $CO_2$ level were $50.3{\mu}g/m^3$ and 792.1ppm. Sixteen child daycare centers (94.2%) met the guidelines of the $PM_{10}$ level, so did thirteen child daycare centers (76.5%) in the $CO_2$ level. $CO_2$ levels were significantly low in child daycare centers using air cleaners than those do not using them (t=-6.03, p<.001). Types of child daycare centers were significantly correlated to the levels of $CO_2$, which public child daycare centers were low in $CO_2$ levels than those of private child daycare centers (t=-2.54, p=.013). There was no significant correlation between teachers' awareness and management attitude of indoor air quality while teachers' awareness of indoor air quality significantly raised the frequency of carpet cleaning. Methods of cleaning routines were significantly correlated with $PM_{10}$, and $CO_2$ levels. Conclusion: The $PM_{10}$ and $CO_2$ concentrations in child daycare centers were satisfactory. Those conditions are affected by general characteristics of child daycare centers and teachers' attitude regarding management of indoor air quality.

겨울철 연소오염원에 의한 도심 고층 아파트의 실내공기오염 (Indoor Air Pollution of a High-rise Apartment Caused by Combustion Sources in Winter)

  • 김종범;이광재;류성희;이재영;우성호;이승복;김경환;윤성택;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제10권3호
    • /
    • pp.119-130
    • /
    • 2014
  • Home is a major living environment of children. In urban area, indoor air at home could be severely influenced by combustion sources such as vehicle exhaust and cooking. In this work, the air quality of a high-rise apartment was investigated by monitoring combustion-related air pollutants at both indoor and outdoor in winter of 2014. From 48-h continuous monitoring data, large amount of $NO_x$ was observed at the balcony of the high-rise apartment during the morning traffic hours. It deteriorated indoor air quality of the apartment. During the cooking activity, high peak episodes of ultrafine particles were seen. It was concluded that effects of vehicle exhaust and cooking activity on the indoor air of the high-rise apartment could be easily checked by $NO_x$ and ultrafine particle indicators, respectively.

교사 내 플랜트 모델 유형별 적용에 따른 공기질 변화 (Changes in Air Quality through the Application of Three Types of Green-Wall Model within Classrooms)

  • 양호형;김형주;방성원;조흔우;이형석;한승원;김광진;김호현
    • 한국환경보건학회지
    • /
    • 제49권6호
    • /
    • pp.295-304
    • /
    • 2023
  • Background: Adolescents are relatively more sensitive than adults to exposure to indoor pollutants. The indoor air quality in classrooms where students spend time together must therefore be managed at a safe level because it can affect the health of students. Objectives: In this study, three types of green-wall models were applied to classrooms where students spend a long time in a limited space, and the resulting effects on reducing PM were evaluated. Methods: In the middle school classrooms which were selected as the experimental subjects, IoT-based indoor air quality monitoring equipment was installed for real-time monitoring. Three types of plant models (passive, active, and active+light) were installed in each classroom to evaluate the effects on improving indoor air quality. Results: The concentration of PM in the classroom is influenced by outdoor air quality, but repeated increases and decreases in concentration were observed due to the influence of students' activities. There was a PM reduction effect by applying the green-wall model. There was a difference in PM reduction efficiency depending on the type of green-wall model, and the reduction efficiency of the active model was higher than the passive model. Conclusions: The active green-wall model can be used as an efficient method of improving indoor air quality. Additionally, more research is needed to increase the efficiency of improving indoor air quality by setting conditions that can stimulate the growth of each type of plant.

Sick House/Building Syndrome in JAPAN -Current Status and Practical Research on Indoor Air Quality-

  • Sekine Yoshika
    • 한국환경보건학회지
    • /
    • 제31권3호
    • /
    • pp.207-214
    • /
    • 2005
  • Many Japanese today are suffering from health disorders related to their living environment, such as allergies and hypersensitivity to chemical substances. The Sick House/Building Syndrome has been a serious problem since 1996, due to low level exposure to hazardous chemicals such as formaldehyde and volatile organic compounds (VOCs) emitted in airtight houses. This paper aims to show current status of the syndrome in Japan and practical researches to promote prevention of, and improvement to indoor air pollution due to chemicals.

실내 공기의 다성분 측정시스템 개발에 관한 연구 (Measurement system of multi-components in indoor air quality)

  • 김보환;이진하;김태진
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.125-130
    • /
    • 2005
  • Six modules composed of individual sensors and circuit systems for oxygen, temperature, humidity, volatile organic compounds, dust, carbon dioxide, in the indoor air quality control were examined to see their individual performances. Experimental results showed that all the six modules were in good linearity with individual concentration variations

에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교 (Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units)

  • 신동호;우창규;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

공동주택의 여름철 수용 쾌적온도 범위와 거주자의 냉방기 사용행위에 관한 연구 (A Study on Acceptable Thermal Comfort Zone and Resident Behavior of Operating Cooling Devices in Apartments)

  • 전정윤;배누리
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.477-486
    • /
    • 2005
  • In this study, indoor thermal environment, resident behavior of operating cooling device, and thermal comfort vote are investigated at the living room of apartment during summertime in Seoul. Based on the results of the investigation, indoor air temperatures that residents turn air conditioners (especially for cooling load in this research) on and off were found out. The relationships between outdoor weather condition and the number of days using air conditioner, and whether operating patterns of the devices were also found out. The acceptable thermal comfort zone is figured out from these results, and this research is expected to contribute to the development of household air conditioner. The results can be summarized as the followings; Residents turned the air conditioner on at $29.76^{\circ}C$ of indoor air temperature, and $28.89^{\circ}C$ of $SET^\ast$. And turned the air conditioner off at $27.31^{\circ}C$ of indoor air temperature, and $23.70^{\circ}C$ $SET^\ast$. Therefore, acceptable thermal comfort zone could be lied between these temperatures. If comfortable indoor thermal environment can be obtained with various architectural passive cooling techniques based on the results, energy consumption of cooling devices will be reduced.

IFC-BIM을 활용한 실내공기질 인증 요구정보 생성 자동화 (Automation of Information Extraction from IFC-BIM for Indoor Air Quality Certification)

  • 홍심희;여창재;유정호
    • 한국건설관리학회논문집
    • /
    • 제18권3호
    • /
    • pp.63-73
    • /
    • 2017
  • 실내에서 보내는 시간이 증가함에 따라, 쾌적한 실내환경에 대한 요구가 증가되고 있다. 또한, 새집증후군과 같은 문제들에 관심이 집중되면서 실내공기질에 관한 요구 역시 증가되고 있다. 정부에서는 이러한 요구에 따라 실내환경을 관리하기 위하여 다양한 정책 및 제도를 제정하였으며, 공공건물에서의 친환경제도 인증을 필수화하였다. 실내공기질과 관련된 인증제도는 크게 3가지로 도면기반으로 인증을 평가하는 건강친화형 주택건설기준과 녹색건축인증 그리고 측정정보 기반으로 인증을 평가하는 실내공기질 인증이 있다. 이중 도면기반으로 인증을 평가는 제도들을 업무의 비중 대비 과도한 업무량이 요구된다. 친환경인증업무를 수행하는 한 회사의 인터뷰 결과 평균 업무비중보다 2배 이상의 소요시간이 필요한 것으로 조사되었다. 이는 2D기반의 작업환경에서 면적에 관한 정보들을 일일이 수작업으로 측정하여 필요이상의 업무를 수행하고 있기 때문으로 분석된다. 따라서 본 연구에서는 3D기반의 BIM모델을 이용한 실내공기질 평가 자동화 프로세스를 제시한다. 국제표준 포맷인 IFC 파일을 이용하여 필요한 면적정보 및 자재정보를 자동으로 추출하고 이를 모델에 적용하여 자동화하는 과정을 제시한다. 본 연구는 인증을 위해 필요한 업무시간을 단축하고 업무효율성을 높이는 것에 기여할 것으로 기대된다.

거주기간 증가에 따른 신축 공동주택의 실내오염도 변화추이 (Tendency of the indoor pollutants along with increased dwelling period at new apartments)

  • 장성기;류정민;서수연;임정연;이우석
    • 분석과학
    • /
    • 제20권6호
    • /
    • pp.453-459
    • /
    • 2007
  • 신축공동주택의 실내공기질에 영향을 미치는 휘발성유기화합물 및 카보닐화합물의 농도와 입주 후 거주기간에 따른 오염도 변화추이를 파악하고자 입주 후 신축 공동주택 120세대를 대상으로 실내공기 오염도를 조사하였다. 신축 공동주택 입주 후 TVOC (Total Volatile Organic Compounds; TVOCs)평균농도는 $688.61{\mu}g/m^3$으로 나타났으며, 포름알데히드, 톨루엔, m, p-자일렌, 아세톤, 에틸벤젠이 $158.56{\mu}g/m^3$, $146.58{\mu}g/m^3$, $69.28{\mu}g/m^3$, $63.80{\mu}g/m^3$, $29.65{\mu}g/m^3$의 순으로 높게 나타났다. 또한, 대부분의 실내오염물질들은 입주 후 거주기간이 증가함에 따라 평균농도가 감소하는 경향을 나타내었으나, d-리모넨의 경우 입주 후 2개월에서 10개월까지 지속적으로 증가하는 것으로 나타났다. 또한, 톨루엔, 에틸벤젠, m, p, o-자일렌 등의 주요오염물질이 전체 VOCs에서 차지하는 비율은 38.8%로 나타났으며, 거주기간에 증가함에 따라 구성비율이 감소하는 것으로 나타났다.