• Title/Summary/Keyword: Indoor Air

Search Result 2,362, Processing Time 0.034 seconds

Practical Algorithms for the Effective Operation of a $CO_2$ Air-conditioner (이산화탄소에어컨의 효율적인 운용을 위한 실용알고리즘)

  • Han, Do-Young;Park, Seung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.435-440
    • /
    • 2009
  • For the effective control of a $CO_2$ air-conditioning system, the system high-side pressure algorithm, the indoor temperature algorithm, and the outdoor fan algorithm were developed. The system high-side pressure algorithm was composed of the setpoint algorithm, the reset algorithm, and the electronic expansion valve control algorithm. The indoor temperature algorithm was composed of the compressor control algorithm and the indoor fan control algorithm. These algorithms were tested by using mathematical models developed from the previous study. Results from the setpoint step change test and the disturbance test showed good control performances. Therefore, algorithms developed in this study may practically used for the control of a $CO_2$ air-conditioning system.

  • PDF

Study on the volatile organic compounds and suspended microorganism in a high-speed train passenger cabin (고속열차 객실의 휘발성유기화합물 및 부유미생물 분석 연구)

  • Cho, Young-Min;Jung, Woo-Sung;Park, Duck-Shin;Kwon, Soon-Bark;Park, Eun-Young;Jung, Mi-Young;Mok, Jin-Yong;Lee, Jong-Beom
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1045-1050
    • /
    • 2008
  • The public interest on the indoor air quality of a high-speed train passenger cabin is drastically increasing due to the sealing of cabin. In this study, the concentration of volatile organic compounds and suspended microorganism in the high-speed train passenger cabin was investigated. There have been many studies on the indoor air quality of the high-speed passenger cabin, but the study on the indoor air quality without boarding of passengers were hardly carried out. As a result, it was very difficult to identify the exact source of air pollutants in the cabin. In this study, the indoor air quality of passenger cabin without any passengers was investigated so that the contribution of passengers as the source of various pollutants could be estimated.

  • PDF

Development of IoT based Real-Time Complex Sensor Board for Managing Air Quality in Buildings

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.75-82
    • /
    • 2018
  • Efforts to reduce damages from micro dust and harmful gases in life have been led by national or local governments, and information on air quality has been provided along with real-time weather forecast through TV and internet. It is not enough to provide information on the individual indoor space consumed. So in this paper, we propose a IoT-based Real-Time Air Quality Sensing Board Corresponding Fine Particle for Air Quality Management in Buildings. Proposed board is easy to install and can be placed in the right place. In the proposed board, the air quality (level of pollution level) in the indoor space (inside the building) is easy and it is possible to recognize the changed indoor air pollution situation and provide countermeasures. According to the advantages of proposed system, it is possible to provide useful information by linking information about the overall indoor space where at least one representative point is located. In this paper, we compare the performance of the proposed board with the existing air quality measurement equipment.

Isolation and Identification of Filamentous Fungi from Indoor Air of a Sogokju Traditional Rice Wine Factory (소곡주 공장의 공기로부터 곰팡이의 분리 및 동정)

  • Park, Ji-Eun;Jeon, Young-Jae;Kim, Ji-Hye;Kim, Seong-Hwan
    • The Korean Journal of Mycology
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • To investigate the mycoflora of indoor air in a Sogokju, traditional rice wine, factory, fungi were sampled and analyzed from the air of several rooms in the factory using an Anderson air sampler and from two kinds of Nuruk. Twelve fungal species belonging to the genera of Aspergillus, Penicillium, Gibberella, Cladosporium, and Talaromyces were isolated. Species belonging to Aspergillus and Penicillium genera were the major species. Seven different species of Penicillium were isolated from each different room of the factory. The Aspergillus species found from indoor air of the factory was also found from Nuruk. Rhizopus sp. was commonly isolated from Nuruk but not from indoor air of the factory. This is first report of fungi present in indoor air of a traditional rice wine factory in Korea.

Seasonal and Locational Concentrations of Particulate Air Pollutants in Indoor Air of Public Facilities in Taegu Area (대구지역 공중위생법 규제대상시설의 실내공기중 입자상 오염물질의 계절별 및 지점별 농도분포 특성)

  • 백성옥;송희봉
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.163-176
    • /
    • 1998
  • In this study, airborne particle samples were obtained to determine the concentrations of particulate air pollutants in indoor and outdoor air of public facilities in Taegu area. Total of 12 public facilities, regulated by the Public Sanitary Law, were selected as sampling sites, which include three underground arcades, one railway and two bus terminals, three general hospitals, and three department stores. In each place, sampling was carried out seasonally during the period of October 1994 to July 1995, and four samples per each site per season were collected both indoors and outdoors simultaneously. After determination of suspended particulate matter (SPM) mass concentrations, the particle samples were divided into two parts for subsequent chemical analysis: one for the analysis of trace elements and the other for water soluble ions. Seasonal levels of SPM appeared to be the highest in spring and the lowest in summer both indoors and outdoors, while locational variations of highest in statioyterminals, and lowest in department stores . SPM concentrations indoors and outdoors did not show any significant differences each other in most places . However, there were significant correlations between indoor and outdoor levels of SPM and other chemical species . These results indicates that indoor SPM levels are likely to be significantly affected by outdoor sources in many places. The most significant source of SPM was estimated to be the resuspension of soil/road dust both indoors and outdoors . The concentrations of toxic heavy metals (Pb, Cd, Cr, Cu) in underground arcades appeared to be very much lower than the established air quality guidelines for underground environments. In addition, it is likely that micro-environmental parameters such as temperature, humidity, and air velocity, play a less significant role than outdoor air quality as a factor affecting the levels of particulate pollutants in indoor environments of public facilities in Taegu area.

  • PDF

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.

HEALTH RISK ASSESSMENT OF HOUSEHOLD EXPOSURE TO INDOOR RADON IN ASSOCIATION WITH THE DWELLING'S AGE

  • Shahrokhi, Amin;Shokraee, Forough;Reza, Ali;Rahimi, Hasn
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • Radon is a naturally occurring radioactive gas and a major indoor contribution of exposure to ionizing radiation in dwellings. $^{222}Rn$ is a health hazard gas what is responsible for thousand lung cancer deaths every year. In this study, indoor radon concentrations present in thirty representative houses in Mahallat city, Iran, were determined in order to estimate lung cancer risk associated with residential radon exposure. Long-term passive method, using CR-39, was used to measure the radon concentration. The results showed an association between the age of the dwellings and the indoor radon concentration that was found, in that the concentration of radon tended to increase as the age of the dwelling also increased. The indoor radon concentrations were calculated to be within the range of $23{\pm}2$ to $350{\pm}26Bq{\cdot}m^{-3}$, with an average of $158Bq{\cdot}m^{-3}$. The annual effective dose from inhaled radon and its decay products was calculated between $0.8{\pm}0.1$ and $12.3{\pm}0.9mSv{\cdot}y^{-1}$, with an average of $5.5mSv{\cdot}y^{-1}$. By taking into consideration the EPA recommendation and ICRP statement, the average annual risk of lung cancer from inhaled radon was calculated as 0.09%, 0.06%, 0.01%, and 0.03% for current smokers (CS), those who had ever smoked (ES), never smokers (NS) and the general population, respectively.

Characterization of Volatile Organic Compounds in New Residential Buildings Before Moving-in

  • Shin, Seung-Ho;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2012
  • This study investigated the characteristics of selected volatile organic compounds(VOCs) in newly-finished residential buildings, before the occupants moved in. This investigation was carried out by measuring the indoor and outdoor concentrations of selected VOCs before the occupants moved in and by utilizing an indoor mass balance model. Among 25 target VOCs, five aromatics(benzene, ethyl benzene, toluene, m,p-xylene, and o-xylene) were detected in all samples of both indoor and outdoor air. Toluene was most abundant VOC in the indoor air of new apartments, with a median value of 168 mg $m^{-3}$. Unlike other VOCs, halogenated compounds would not be significantly emitted from building materials. The indoor air concentrations of all selected VOCs, except for 1,3,5-trimethyl benzene, exhibited significant correlations each other, while for outdoor air concentrations, five aromatics only were significantly correlated between them. The emission rate of toluene was higher for the current study(median value, 76.8 mg $m^{-2}\;h^{-1}$) than for a previous study, while the emission rates of limonene, a-pinene and b-pinene(geometric means of 2.4, 13.8 and 9.6 mg $m^{-2}\;h^{-1}$, respectively) were lower and the emission rates of m,p-xylene and 2-butanone(geometric means of 10.9 and 21.3 mg $m^{-2}\;h^{-1}$, respectively) were similar. Although there were a few exceptions, the emission strengths are likely proportional to indoor temperature, and appear to reversely proportional to air exchange rate.

The Characteristics of Indoor Air Quality Variation in Underground Parking Lots of Apartments located in Northern Gyeonggi Province (경기도 북부지역 아파트의 지하주차장 실내공기질 변동 특성)

  • Park, Hyun-Ku;Jung, Yeon-Hoon;Kim, Byeong-Lok;Kim, Jin-gil;Shin, Hyung-Soon;Lee, Sang-Soo;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.250-258
    • /
    • 2018
  • Objectives: The study examined indoor air quality during daytime and commute times in underground parking lots in five apartments located in northern Gyeonggi province. Methods: This study examined the temporal characteristics of $PM_{10}$, $CO_2$, CO, HCHO and VOCs in the indoor air quality of the underground parking lots in five apartments. Results: $PM_{10}$ concentration in daytime were ranged from 37.4 to $69.9{\mu}g/m^3$ which complied with the indoor air quality maintenance standard ($200{\mu}g/m^3$) and Gyeonggi province ordinance standard ($180{\mu}g/m^3$). However $PM_{10}$ concentrations in commuting time were in range of $447.3{\sim}944.0{\mu}g/m^3$ that exceeded for both criteria. The $CO_2$, CO and HCHO concentrations complied with the standard. The VOCs indicated high tendency in the order of toluene, xylene, ethylbenzene and benzene. This tendency was more apparent in commuting time than daytime. Conclusion: All indoor parking lots of five apartments were equipped with ventilators. However the most apartment residents did not operate blowers to save electricity and the lack of interest for indoor air quality. In order to improve the indoor air quality of underground parking lots in apartment, operating ventilation system during commuting time is recommended.

Characteristics of VOCs and Formaldehyde Emitted from Floorings (바닥재로부터 방출되는 휘발성유기화합물과 폼알데하이드 특성)

  • Park, Hyun-Ju;Jang, Seong-Ki;Seo, Soo-Yun;Lim, Jun-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • Since the seventies and the oil crisis, energy-saving measures have led to a reduction in the ventilation of room. The use of synthetic materials which emit various chemical substances had led to an increase in the concentration of indoor pollutants. "Sick building syndrome (SBS)" and "Sick house syndrome (SHS)" are worldwide problems. Also, the number of complaints about indoor air pollution caused by VOCs (Volatile organic compound) and HCHO (Formaldehyde) has increased. It is important that evaluating and understanding emission of indoor air pollutant from building materials. The object of this study was to evaluate emission test method for flooring such as wood based flooring, carpet tile, rubber tile, PVC sheet and tile, and to determine emission of TVOC and form-aldehyde. The quantity of TVOC and carbonyl compounds emission were sampled and measured by Tenax TA and gas chromatography/mass spectrometry (GC/MSD), 2,4-DNPH cartrige with ozone scrubber and high performance liquid from flooring. The TVOC concentration emitted from carpet tile was ($7.419\;mg/m^2 h$) the highest among 5 groups of test materials. In wood based flooring and PVC tile, the emitted concentration of toluene was high. And the dodecane emission was highest in carpet. The concentration of TVOC decreased by an increase in emission test period. After 7 days, the concentration of TVOC from floorings were about 50% below of the concentration at the first day. TVOC emission from wood based flooring, carpet tile, rubber tile, PVC sheet and tile were decreased in 28 days and remained steady after about 15 days. The concentration of formaldehyde emission from floorings showed extremely low.