• 제목/요약/키워드: Indoor Air

검색결과 2,352건 처리시간 0.038초

염소살균과 오존-염소살균 수도수의 사용과 관련한 가정 트리할로메탄 노출 비교평가 (Comparison of Household Trihalomethanes (THMs) Exposure Associated with Use of Municipal Tap Water Treated with Chlorine or Ozone-Chlorine)

  • 조완근;권기동;동종인;정용
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.627-635
    • /
    • 2004
  • Evaluated were household THMs exposure associated with the use of municipal tap water treated with chlorine and with ozone-chlorine. The current study measured the THMs concentrations in the tap water and indoor and outdoor air in the two types of household, along with an estimation of THMs exposure from water ingestion, showering, and the inhalation of indoor air. Chloroform was the most abundant THMs in all three media, yet no bromoform was detected in any sample. Contrary to previous findings, the fall water THMs concentrations exhibited no significant difference between the chlorine and ozone-chlorine treated water. However, the spring median chloroform concentration in the tap water treated with chlorine (17.6 ppb) was 1.3 times higher than that in the tap water treated with ozone-chlorine (13.4 ppb). It is suggested that the effects of the water parameters should be considered when evaluating the advantage of ozone-chlorine disinfection for THMs formation over chlorine disinfection. The indoor air THMs concentration trend was also consistent with the water concentration trend, yet the outdoor air THMs concentrations did not differ significantly between the two types of household. The indoor to outdoor air concentration ratios were comparable with previous studies. The THMs exposure estimates from water ingestion, showering, and the inhalation of indoor air suggested that, for the residents living in the surveyed households, their exposure to THMs in the home was mostly associated with their household water use, rather than the indoor air. The THMs exposure estimates from tap water ingestion were similar to those from showering.

저전력 무선센서 네트워크를 이용한 빌딩 내 환경공조 시스템 (Indoor Air-Conditioning System in building Using Lower Power Wireless Sensor Network)

  • 이승철;정완영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.397-400
    • /
    • 2007
  • 본 연구에서는 소형, 저전력 센서와 센서 인터페이스를 구현하여 빌딩내의 실내 공조시스템과 함께 연동하고자 하였다. 빌딩 내 공조시스템은 저비용인 저전력 무선센서 노드간의 네트워크를 형성하여 각 룸마다 오염농도를 분석하여 룸의 오염 상태를 확인 한 후 실내 공조시스템에 있는 팬을 자동으로 조절해서 최적의 환경을 조성할 수 있게 하였다. 또한 GUI 인터페이스를 통해 각 룸의 있는 센서노드의 배터리 상태를 확인할 수 있는 것은 물론 모니터링이 필요한 가스의 농도와 온도 등을 확인 할 수도 있었다. 본 논문에서는 IEEE 802.15.4와 Zigbee를 지원하는 근거리 통신망을 갖는 저전력 무선센서 노드를 이용하여 무선센서 네트워크를 형성하기 위해 Ad-hoc 기능을 갖는 Simple forwarding routing을 구현하였다. 그리고 가스센서의 전력소모를 줄이기 위해서 전기화학적으로 환원 또는 산화하여 외부회로에 흐르는 전류를 측정하는 저전력 전기화학식 가스센서를 사용하였으며, 가스센서 인터페이스를 저전력으로 동작하도록 설계하였다.

  • PDF

고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화 (A study on the effect on indoor air quality by ventilation system operation in buses)

  • 안선민;이정섭;심인근;김호현
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.

청정환기장치 최적제어를 위한 IoT 기반 실시간 공기질 모니터링 플랫폼 구현 (IoT Based Real-Time Indoor Air Quality Monitoring Platform for a Ventilation System)

  • 수던 프라사드 우프레티;김유신
    • 인터넷정보학회논문지
    • /
    • 제21권6호
    • /
    • pp.95-104
    • /
    • 2020
  • 본 연구는 사물인터넷(IoT) 센서를 이용해 실내공기질에 주요한 영향을 미치는 미세먼지, 초미세먼지, 이산화탄소, 유기화학물과 온도, 습도 데이터를 실시간으로 수집/분석할 수 있는 실시간 실내공기질 모니터링 서비스를 클라우드 플랫폼으로 구현하였다. 이를 실내공기 정화시설인 청정환기장치와 연동하여 실시간 실내공기질 상태에 따라 환기장치 최적관리할 수 있도록 하였다. 본 플랫폼은 청정환기장치 내외부에 장착된 실내공기질 측정 센서로부터 실시간으로 데이터를 수집하는 IoT 데이터 수집부, 수집된 데이터를 클라우드 환경에서 가공/처리/적재하는 클라우드 데이터 처리부, 적재된 빅데이터를 분석하고 공기질 현황을 웹과 모바일에 시각화하여 보여주는 데이터 분석 서비스부로 구성된다. 그리고 이러한 플랫폼의 가동과 효과를 검증하기 위해 공기질에 민감한 영유아의 교육 생활환경인 국공립 어린이집 교실을 대상으로 실증을 실시하였다. 모든 분석 결과는 웹과 모바일에서 실시간으로 시각화 서비스될 수 있도록 실증 구현하였고, 환기장치의 실내공기질 개선효과는 실내공기질 측정 센서들의 측정값을 통계적으로 검증하여 공기질 개선에 기여하고 있음을 확인하였다.

혼합 공조 시스템의 EER(A) 평가 (Evaluation of energy efficiency ratio in the mixed air conditioner system)

  • 김병순;이승홍
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.542-548
    • /
    • 1999
  • Instead of testing split air conditioners, an empirically based calculation procedure may be used to estimate the Energy Efficiency Ratio at ARI A test conditions. Typically, the system involving the indoor unit well sold and the given outdoor unit is called the matched system. All other systems involving a given outdoor unit and other indoor units are called the mixed systems. To estimate the EER(A) for the mixed systems, EER(A) for the matched system must be known, Generally, the EER(A) for the matched system is known. This procedure relies on independent measurements and calculations made on an outdoor unit in conjunction with a matched indoor and a mixed indoor coil. A heat pump simulation model was used to quantify the effects of individual system components on the system performance. The procedure is applicable to all air-conditioning units having rated cooling capacities less than 19,000W and charged with refrigerant 22.

  • PDF

외기 미세먼지와 탑승객수에 따른 객실 PM10 농도변화 연구 (Study on PM10 levels by the concentration of outdoor aerosols and the number of passengers in railway cabin)

  • 박은영;박덕신;권순박;조영민;김세영;정미영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1816-1820
    • /
    • 2008
  • Indoor air quality in public transportation such as railway, subway and bus is hard to control because of spatial restrict and variation of passenger's number. On January 2007, The Ministry of Environment announced "the guideline of indoor air quality in public transportation" for the concentration managements of particulate matter and carbon dioxide. In this study, we measured the PM10 concentration inside the Mugunghwa-ho passenger cabin and outdoor air and counted passengers. By the statistical analysis using SigmaPlot 2001 and SPSS 13.0, we found that indoor PM10 concentration is significantly affected by outdoor air. It is suggested that the air quality of inflow to the passenger cabin for air exchange must be controlled to support the indoor environment comfortably.

  • PDF

광합성 세균 희석 비율에 따른 시멘트 경화체의 응결 특성 (Setting time properties of cement matrix according to photosynthetic bacterial dilution ratio)

  • 편수정;김대연;임정준;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2018
  • In recent years, harmful substances and fine dust in the air are caused by respiratory and cardiovascular diseases through various mechanisms when they are introduced into the human body through respiration, thereby exacerbating human health and causing cancer by prolonged exposure do. In order to prevent such fine dust from being introduced into the room and to improve indoor air quality, improvement of air quality has attracted attention. Among indoor air pollutants, fine dust and CO2 are pollutants that are directly affected by indoor number and activity. The purpose of this study is to evaluate the basic performance of cement matrix using photosynthetic bacteria as a basic study of fine dust and CO2 adsorption type matrix to suppress indoor air pollution and improve air quality.

  • PDF

식물에 의한 계절별 실내공기오염물질 저감효과에 관한 연구 (A Study on Indoor Air Pollutants Reduction Effect by Plants per Season)

  • 손정은;김용식;손장열
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 2008
  • This study aims at examining the reduction of indoor air contaminants by plants placed in an indoor space. The effect of reducing the concentration of air contaminants by three species of plants was studied in a full-scale mock-up model. Field measurements were performed using Aglaonema brevispathum, Pachira aquatica and Ficus benjamiana which were verified as air-purifying plants by NASA. Their positions and amount were controlled. Two conditions for the amount of plants(10%, 5%) and positions(sun-shine, scatter) were used in two separate rooms whose dimensions are identical. The concentration of Volatile Organic Compounds(VOCs) was monitored three hours after the plants were placed and three days after the plants were placed. The variations of concentration of Benzene, Toluene, Etylbenzene, Xylene, Stylene and Formaldehyde, which are all known as the major elements of Volatile Organic Compounds were monitored. The more plants were used, the more a reduction of indoor air contaminants occurred. The effect of reducing the concentration of air contaminants increased when the amount of plants increased.

일부지역 치과위생사의 치과진료실 실내공기질에 대한 만족도 및 자각증상 비교 (The satisfaction and subjective symptom level by indoor air quality in dental parlor in Capital and Jeon-nam area)

  • 최미숙
    • 한국치위생학회지
    • /
    • 제11권3호
    • /
    • pp.405-417
    • /
    • 2011
  • Objectives : A precedent research has documented that indoor air pollution is closely associated with increased the risk of symptom and decreased in job satisfaction. This study was conducted in an effort to assess the relationship of indoor air quality to self-perceived symptom and satisfied with working environment. Methods : This research is based on self-filling survey which 393 dental hygienists who work in seoul and Jeon-nam area participated on October 2010 through January 2011. This survey was compared and analyzed about the level of satisfaction and subjective symptom by the indoor air quality that dental office's working environment. Results : The result of satisfaction degree of hospital working environment was pretty low about office air. Most people mentioned that they were sore and dull all over the back, shoulder, and neck. Also, they were drowsy and exhausted in work place. Conclusions : In conclusion, it is need to improve their quality of life and mental health by developing proper air conditioning system and using one in their work place.

창원지역 신축학교의 실내공기질 현장평가 연구 (A Study on the Field Evaluation about the Indoor Air Quality of Schools Newly Built in Changwon)

  • 유종훈;강은혜;손영환;하석용;최정민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1244-1249
    • /
    • 2006
  • Because students are spending more time in their classroom for learning and study, indoor air quality problems in school classrooms are very important. when the classroom is built for the first time, namely newly built school, the selection of inside finishing material is directly connected with indoor air quality problems especially with HCHO and TVOC. But until now, there is no plenty of study about this. Moreover, there are some concerns about the desks and chairs which are used in classroom will affect the air quality. but almost no study is being made at all Therefore, this study focuses on the field survey and analysis of classroom indoor air quality in newly built schools in Changwon. In this study filed surveys and analysis are conducted as follows. 1) The effect of the material difference in general classroom. 2) The effect of the material and loading ratio difference in special classroom. 3) The effect of the desks and chairs in general classroom.

  • PDF