• Title/Summary/Keyword: Indoor/outdoor ratio

Search Result 109, Processing Time 0.022 seconds

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Weatherability of Epoxy Cement Mortars without Hardener (경화제를 첨가하지 않은 에폭시 시멘트 모르타르의 내후성)

  • Jo, Young-Kug
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.801-809
    • /
    • 2006
  • Epoxy resin has widely been used as adhesives and corrosion-resistant paints in the construction industry for many years, since it has desirable properties such as high adhesion and chemical resistance. Until now, in the production of conventional epoxy cement mortars, the use of any hardener has been considered indispensable for the hardening of the epoxy resin. However we have noticed the fact that even without any hardener, the hardening process of the epoxy resin can proceed by the action of hydroxides in cement mortars. As a result the disadvantages of the two-component mixing of the epoxy resin and hardener have been overcome. The purpose of this study is to evaluate the mechanical properties and durability of epoxy cement mortar without a hardener exposed at indoor and outdoor for one year. The epoxy cement mortars without and with a hardener were prepared with various polymer-cement ratios, and tested for weight change, flexural and compressive strengths, water absorption, carbonation depth and pore size distribution. Especially, the basic properties of the epoxy cement mortars without hardener are discussed in comparison with ones with the hardener. From the test results, it is concluded thai the epoxy cement mortars without a hardener exposed at indoor and outdoor for one year have higher strength and better durability than ones with the hardener within the polymer-cement ratios of 10 to 20%.

Analysis and Exposure Assessment of Factors That Affect the Concentration of Ambient PM2.5 in Seoul Based on Population Movement (인구 유동에 따른 서울시 대기 중 초미세먼지 농도 변화 요인 분석 및 노출평가)

  • Jaemin Woo;Jihun Shin;Gihong Min;Dongjun Kim;Kyunghwa Sung;Mansu Cho;Byunglyul Woo;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.1
    • /
    • pp.6-15
    • /
    • 2024
  • Background: People's activities have been restricted due to the COVID-19 pandemic. These changes in activity patterns may lead to a decrease in fine particulate matter (PM2.5) concentrations. Additionally, the level of population exposure to PM2.5 may be changed. Objectives: This study aimed to analyze the impact of population movement and meteorological factors on the distribution of PM2.5 concentrations before and after the outbreak of COVID-19. Methods: The study area was Guro-gu in Seoul. The research period was selected as January to March 2020, a period of significant population movement changes caused by COVID-19. The evaluation of the dynamic population was conducted by calculating the absolute difference in population numbers between consecutive hours and comparing them to determine the daily average. Ambient PM2.5 concentrations were estimated for each grid using ordinary kriging in Python. For the population exposure assessment, the population-weighted average concentration was calculated by determining the indoor to outdoor population for each grid and applying the indoor to outdoor ratio to the ambient PM2.5 concentration. To assess the factors influencing changes in the ambient PM2.5 concentration, a statistical analysis was conducted, incorporating population mobility and meteorological factors. Results: Through statistical analysis, the correlation between ambient PM2.5 concentration and population movement was positive on both weekends and weekdays (r=0.71, r=0.266). The results confirmed that most of the relationships were positive, suggesting that a decrease in human activity can lead to a decrease in PM2.5 concentrations. In addition, when population-weighted concentration averages were calculated and the exposure level of the population group was compared before and after the COVID-19 outbreak, the proportion of people exceeding the air quality standard decreased by approximately 15.5%. Conclusions: Human activities can impact ambient concentrations of PM2.5, potentially altering the levels of PM2.5 exposure in the population.

Studies on Culex pipiens Mosquitoes in Korea 1. Feeding and Resting Behavior of Culex pipiens pallens Coquillett (韓國産 Culex pipiens에 관한 硏究: 1. Culex pipiens pallens Coquillett 의 吸血 및 休息習性 調査)

  • 李漢一
    • The Korean Journal of Zoology
    • /
    • v.13 no.2
    • /
    • pp.51-56
    • /
    • 1970
  • Studies on the feeding and resting behavior of Culex pipiens pallens, a possible vector of Japanese encephalitis in Korea, was carried out at Kobu-Ri, Kobu-Myon, Chongup Kun. Cholla Pukdo in 1967. 1. Indoor and outdoor human biting collections showed that 47.3 per cent Culex pipiens pallens were collected indoors and 52.7 per cent outdoors. 2.Feeding occurred throughout the night from dusk to dawn, with the peak period from 23:00-24:00 hours outside the house and from 24:00-01:00 hours inside. 3. Culex pipiens pallens females preferred man for their blood feeding to domestic animals. The results of human and cow biting collections showed that the feeding ratio between man and cow was 2.1 to 1. As to the feeding preference to the domestic animals, the ratio among cow, pig and horse was 7.3 to 5.1 to 5.4 4. Daytime resting collections showed that large numbers of Culex pipiens pallens females rest inside the house, especially in the bed room and the chicken pen. As temperatures increased, fewer mosquitoes resting indoors and more mosquitoes rest ing outdoors were caught. By means of sweep-net collections at outdoors resting places, a small number of Culex pipiens pallens mosquitoes were caught in such places as grass fields, vegetable fields, barley fields, bean fields, culverts, bomb shelters, and so on. A comparison between number of mosquitoes collected resting during the day in bedrooms and verandahs with resting collections in the same places at night showed that more mosquitoes were present at night. It was observed that the majority of the unfed females rested before feeding at night.

  • PDF

A Study on Object Detection Algorithm for Abandoned and Removed Objects for Real-time Intelligent Surveillance System (실시간 지능형 감시 시스템을 위한 방치, 제거된 객체 검출에 관한 연구)

  • Jeon, Ji-Hye;Park, Jong-Hwa;Jeong, Cheol-Jun;Kang, In-Goo;An, Tae-Ki;Park, Goo-Man
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.24-32
    • /
    • 2010
  • In this paper we proposed an object tracking system that detects the abandoned and removed objects, which is to be used in the intelligent surveillance applications. After the GMM based background subtraction and by using histogram method, the static region is identified to detect abandoned and removed objects. Since the system is implemented on DSP chip, it operates in realtime and is programmable. The input videos used in the experiment contain various indoor and outdoor scenes, and they are categorized into three different complexities; low, midium and high. By 10 times of experiment, we obtained high detection ratio at low and medium complexity sequences. On the high complexity video, successful detection ratio was relatively low because the scene contains crowdedness and repeated occlusion. In the future work, these complicated situation should be solved.

Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology (대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구)

  • Park, Duck Shin;Kwon, Soon Bark;Cho, Young Min;Jang, Seong Ki;Jeon, Jae Sik;Park, Eun Young
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

The Improvement Proposal of Rural Community Centers : by the Case Studies of 30 Centers in Samnangjin-eup, Miryang City (농촌 마을회관의 현황과 개선방안 연구 -밀양시 삼랑진읍을 대상으로-)

  • Kim, Seong-Ho;Lee, Yoo-Jick
    • Journal of Korean Society of Rural Planning
    • /
    • v.18 no.2
    • /
    • pp.57-68
    • /
    • 2012
  • This study is to suggest the improving methods for rural community centers by analysis of 30 community centers in Samnangjin-eup, Miryang city, Gyeongnam. To fulfill this purpose, the facilities, usable condition and management system were examined. The user needs and level of satisfaction were also investigated through the interviews with 858 citizens. The average size of the centers is $96m^2$, and 73% of them are one-story buildings. Women use the community center more frequently than men in ratio of 6:4. 43.4% of interviewees visit the center 1 or 2 times a month, but on the other hand 27.4% of them use the center almost every day. Recess is surely the main purpose, and health care and community meeting are next two reasons. 67.8% and 72.4% of them are not satisfied with the inside and outside of the community center respectively. The interview results demonstrate that the most important issue is the lack of facilities. To improve the community centers in Samnangjin-eup, first of all, various kinds of indoor and outdoor facilities must be equipped. Secondly, considering the center is the core of rural community life, the qualitative improvement in accommodation is also needed as well as facility diversification. The efficiency of space utilization is another issue. A small piece of land or abandoned space must be utilized. Moreover, it is very critical that the users are mostly seniors and elders, so improvements of facilities will be executed in terms of safety and convenience. Finally, administrative and financial support should be made for the people, so as to maintain the the rural community center on their own.

Comparison of VOCs Concentration Characteristic According to Measurement Methods in Exhibition Hall (휘발성유기화합물(VOCs)의 측정방법에 따른 유물 전시관 내 농도 분포 특성 비교)

  • Lim, BoA;Lee, Sun Myung
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.25-44
    • /
    • 2014
  • In this study, measured annual year and seasonal concentrations of VOCs by Active type and Passive type using the measurement and analysis method in the exhibition hall and outdoor. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the annual average concentrations of TVOC in exhibition room($906.5{\mu}g/m^3$) was greater than for most of the study period, more than 1.8 times the standard in the Ministry of Environment. ${\Sigma}VOCs$ concentration of exhibition room by Active type was higher than Passive type. Some VOCs was decreased with the lapse of time a temporary increase tendencies was. The annual average I/O ratio of TVOC was 9.0, ${\Sigma}VOCs$ was confirmed to occur in a large amount inside the exhibition hall ${\Sigma}VOCs$ was studied to 34.0. Correlation coefficient of ${\Sigma}VOCs$ was 0.367. Toluene was 0.567 that the survey was the largest analysis to the relationship between the two methods.

  • PDF

Development of Processing System for Audio-vision System Based on Auditory Input (청각을 이용한 시각 재현 시스템의 개발)

  • Kim, Jung-Hun;Kim, Deok-Kyu;Won, Chul-Ho;Lee, Jong-Min;Lee, Hee-Jung;Lee, Na-Hee;Yoon, Su-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • The audio vision system was developed for visually impaired people and usability was verified. In this study ten normal volunteers were included in the subject group and their mean age was 28.8 years old. Male and female ratio was 7:3. The usability of audio vision system was verified by as follows. First, volunteers learned distance of obstacles and up-down discrimination. After learning of audio vision system, indoor and outdoor walking examination was performed. The test was scored by ability of up-down and lateral discrimination, distance recognition and walking without collision. Each parameter was scored by 1 to 5. The results were 93.5 +- SD(ranges, 86 to 100) of 100. In this study, we could convert visual information to auditory information by audio-vision system and verified possibility of applying to daily life for visually impaired people.

Analysis of Tapered Slot Antenna for UWB with Directivity Characteristic (지향성 특성을 갖는 UWB 용 테이퍼드 슬롯 안테나 분석)

  • Kim, Sun-Woong;Choi, Dong-You
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.691-697
    • /
    • 2016
  • In this paper, we propose the antenna to appropriate for a UWB communication system, and it meets characteristics for location recognition in predetermined range. Proposed tapered slot antenna was designed through the HFSS simulation tool of Ansys. Inc., it was produced by Taconic TRF-45 based on dielectric constant of 4.5, loss tangent 0.0035, thickness 1.62mm. The tapered slot antenna is analyzed the standing wave ratio and reflection coefficient, radiation pattern in the frequency domain. The impedance bandwidth range of the produced tapered slot antenna is from 3.8 ~ 8.9GHz to 5.1GHz, E-plane and H-plane radiation pattern meet directional antenna characteristics for indoor and outdoor location recognition in predetermined range. The antenna gain is 7.4 dBi(6GHz)in the simulation, the result of measurement demonstrated 7.4 dBi(6 GHz) of antenna maximum gain. Proposed tapered slot antenna meets UWB communication system but simulated and measured results were slightly different.