In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.
Background: Exposure to fine particulate matter (PM2.5) and ozone (O3) poses potential health risks. The Indoor-to-Outdoor ratio (I/O ratio) is a valuable tool for understanding indoor air quality and identifying potential indoor sources. Objectives: The objective of this study was to determine I/O ratios of PM2.5 and O3 by different microenvironments and seasons in Korea. Methods: From December 2021 to November 2023, indoor concentrations of PM2.5 and O3 were monitored every hour in 13 microenvironments (residential indoor, office, school, restaurant, pub, café, study café, private educational institute, PC room, billiard room, screen golf center, supermarket, and shopping mall) in Korea. Hourly outdoor concentrations of PM2.5 and O3 were obtained from local air quality monitoring stations, provided by airkorea.or.kr. The hourly I/O ratio was calculated by the indoor and outdoor concentrations. Results: At the pub, billiard room, and PC room, the median PM2.5 I/O ratio exceeded 1 in all seasons, except in spring at the PC room (0.9), suggesting indoor smoking as a potential cause. The median PM2.5 I/O ratio at the restaurant exceeded 1 in winter, autumn, and summer, except for spring (0.9), indicating significant PM2.5 emission sources in the restaurant. The median O3 I/O ratio was below 0.5 in all seasons and microenvironments. Conclusions: This study provided useful data on relationships between indoor and outdoor pollution in various microenvironments by seasons. These I/O ratios could be applied for more accurate exposure assessment to protect health of human.
초등학생들은 학교에서 많은 시간을 보내고 있으며 실내 공기오염에 더 많이 노출된다. 또한 초등학생들은 신체적으로 성장기에 있으며 어른에 비해 단위체중당 호흡량이 많으므로 실내 공기오염에 대한 민감도가 큰 것으로 알려져 있다. 따라서 학교 실내공기질은 초등학생들의 건강을 위한 중요한 요소이다. 본 연구에서는 서울지역 5개 초등학교에서 측정한 실내외 미세먼지 (Particulate matter: PM) 농도를 이용하여 상관분석을 실시하였다. 이를 통해 실외 PM이 실내 PM에 미치는 영향을 평가하였다. 또한 PM ratio, I/O ratio 등과 같은 통계분석을 진행하였다. 그 결과 초등학교의 실내외 PM의 상관성은 PM10보다 PM2.5와 PM1에서 더 유의미하게 나타났다. Indoor/outdoor (I/O) ratio의 경우 PM10에서 SD를 제외한 4개 초등학교에서 모두 1보다 높게 나타났다 (BB: 2.21, NS: 1.67, IS: 1.73, SI: 1.17). 이는 실내 학생의 활동도가 PM10의 농도에 큰 영향을 미친다는 것을 의미한다.
A survey of radon concentrations in both indoor and outdoor atmospheres was carried out using EIRM and Cup Monitor for the period of February 1996 to March 1997. EIRM were used to measure the indoor and outdoor radon concentration at five major cities university. Cup Monitor were also used to measure the indoor radon concentrations at shopping store, office building, apartment, hospital and house in Seoul. The mean indoor and outdoor radon concentrations at the five major cities(Seoul, Daegu, Daejon, Cwangiu and Busan) were 24.1 Bq/m$^3$and 8.62 Bq/m$^3$, respectively. The ratio of indoor to outdoor radon concentrations ranged front 1.7 to 3.9. Inspection of its seasonal distribute pattern indicates the enhancement during winter relative to summer, consistently for both indoor and outdoor air. The results of the survey showed that the concentrations in basements were clearly higher than those in usual living/working places.
Objective: The purpose of this study was to evaluate the indoor to outdoor ratio (I/O ratio) of time activity patterns affecting PM2.5 concentrations in homes in Korea through a simulation. Methods: The time activity patterns of homemakers were analyzed based on the 'Time-Use Survey' data of the National Statistical Office in 2014. From September 30 to October 2, 2019, the experimenter lived in multifamily housing located in Guro-gu, Seoul. The I/O ratio of PM2.5 concentration was measured by installing sensor-based instruments. Results: The average indoor and outdoor PM2.5 concentrations during the three days were 33.1±48.9 and 45.9±25.3 ㎍/㎥, respectively. The average I/O ratio was 0.75±0.60. The indoor concentration tended to increase when PM2.5 source activity such cooking and cleaning was present and outdoor PM2.5 was supplied through ventilation. Conclusions: This study could be used as basic data for estimating indoor PM2.5 concentrations with personal activity pattern and weather conditions using outdoor concentrations.
본 연구는 황벽나무의 물리, 역학적 성질의 특성과 부후성을 조사하였다. 기건밀도는 실내, 외 방치한 목재에서 각각 0.41, $0.43g/cm^3$로 나타났다. 전수축율 시 T/R비는 실내, 외에서 각각 1.40, 1.32로 나타났다. 흡습성은 온도 $40^{\circ}C$ 상대습도 90% 경우 실내, 외에서 각각 16.30, 15.80%로 나타났다. 압축강도는 실내, 외에서 각각 43.81, 40.33 MPa 휨강도는 84.63, 68.80 MPa, 충격강도는 3.43, $4.00J/cm^2$, 경도는 횡단면에서 각각 47.92, 49.20 MPa로 나타났다. 경도는 횡단면에서 각각 47.92, 49.20 MPa로 나타났다. 1년간 실내에 방치한 목재와 실외에 방치한 목재는 부후에 강하고, 또한 T/R비도 낮은 편으로 치수가 안정한 나무로 판단된다.
This study evaluated the effects of the human activity and outdoor air on concentrations of size-selective particulate matters (PM) by conducting a realtime measurement in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. PM concentrations featured repetitive pattern of increasing during break time (including lunch hours) and cleaning time while decreasing during class hours. This trend was more prominent with inhalable PM and PM10 than fine PMs (PM2.5, PM1.0). The indoor/outdoor (I/O) ratio of inhalable PM and PM10 exceeded 1 while that of fine PMs was close to or below 1. The PM2.5 (out)/PM10 (out) ratio stood at 0.59 (${\pm}0.16$) and the PM2.5 (in)/PM10 (in) ratio was 0.29 (${\pm}0.09$), suggesting that occupant activity had a greater effect upon coarse particles (PM10-PM2.5) than upon fine particles (PM2.5, PM1.0). The correlations between the indoor and the outdoor PM concentrations showed a stronger positive correlation for fine particles than that of coarse particles. The linear regression analysis of PM concentrations indoor and outdoor indicated a higher determinant coefficient ($r^2>0.9$), and consistency for fine particles than in case of coarse particles. In conclusion, the results of this study suggest that the indoor coarse particle concentration is more attributed to occupant activity and the indoor fine particle concentration is more influenced by outdoor air pollution.
A pilot study was conducted in order to investigate the concentrations of indoor and outdoor VOCs (Volatile Organic Compounds) at ten homes and four building offices in Seoul during March-April, 1993. The five components of VOCs(Benzene, Toluene, Ethylbenzene, o-Xylene, m/p-Xylene) were collected using charcoal tube and were analysed using Gas Chromatography(GC) with a Flame Ionization Detector(FID). The mean concentations of indoor VOCs were shown as Benzene of 38.9 .mu.g/m$^{3}$. Toluene of 165.0 .mu.g/m$^{3}$, Ethylbenzene of 21.7 .mu.g/m$^{3}$, o-Xylene of 11.6 .mu.g/m$^{3}$ and m/p-Xylene of 29.3 .mu.g/m$^{3}$, but those corresponding that indoor levels of VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs concentrations was 0.99 for Benzene, 1.23 for Toluene, 5.86 for Ethylbenzene, 5.23 for o-Xylene, 2.41 for m/p-Xylene in homes, while 2.02 for Benzene, 1.15 for Toulene, 0.96 for Ethylbenzene, 1.41 for o-Xylene, 1.38 for m/p-Xylene in offices, respectively. The mean concentrations of VOCs in homes were higher than those levels in offices, while the mean concentration of VOCs during active hour of occupants in a day were higher 1-3 times than the levels during non-active hour. Comparing VOCs levels by building's age, the mean concentrations of Benzene, o-Xylene and m/p-Xylene were higher in new building than old building, but the mean concentrations of Toluene and Etylbenzene in new building were lower than old building. The mean concentrations in all components of VOCs in smoking area were higher than non-smoking area. These results suggested that the VOC levels were affected by various indoor characteristics and behavioral activity of occupants.
Instead of testing split air conditioners, an empirically based calculation procedure may be used to estimate the Energy Efficiency Ratio at ARI A test conditions. Typically, the system involving the indoor unit well sold and the given outdoor unit is called the matched system. All other systems involving a given outdoor unit and other indoor units are called the mixed systems. To estimate the EER(A) for the mixed systems, EER(A) for the matched system must be known, Generally, the EER(A) for the matched system is known. This procedure relies on independent measurements and calculations made on an outdoor unit in conjunction with a matched indoor and a mixed indoor coil. A heat pump simulation model was used to quantify the effects of individual system components on the system performance. The procedure is applicable to all air-conditioning units having rated cooling capacities less than 19,000W and charged with refrigerant 22.
A pilot study on indoor air concentrations of nitrogen dioxide $(NO_2)$ was undertaken in the Seoul area, Korea dudring February-April 1986. Indoor and outdoor data on nitrogen dioxide concentrations were obtained for 48 private residences. Personal exposure to $NO_2$ was also investigated. Indoor outdoor ratio of $NO_2$ concentrations was 0.87, while the correlations between the indoor and outdoor levels were less than 0.50 for $NO_2$. Homes with an unvented space heater had average living room $NO_2$ concentrations approximately double those with a vented space heater. Residences with smokers have significantly higher living room $NO_2$ levels than those without smokers.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.