• 제목/요약/키워드: Individualized crown

검색결과 5건 처리시간 0.02초

연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH)

  • 정회열;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

임상가를 위한 특집 1 - 소아청소년의 외상성 치아손상 (Traumatic Injuries to the teeth in children and adolescent)

  • 박재홍
    • 대한치과의사협회지
    • /
    • 제51권8호
    • /
    • pp.442-450
    • /
    • 2013
  • It is well known that the majority of dental injuries occur in children and adolescent. An injury to the teeth can have serious and long-term consequences, leading to their discoloration, malformation, or possible loss. The emotional impact of such an injury can be far reaching. The majority of dental injuries in the primary and permanent dentitions involve the anterior teeth, especially the maxillary central incisors. Concussion, subluxation, and luxation are the commonest injuries in the primary dentition, while uncomplicated crown fractures are commonest in the permanent dentition. If it is decided to preserve a traumatized primary tooth, it should be carefully observed for clinical and radiographic signs of pulpal or periodontal complications. Radiographs are also examined closely to disclose any damage to the permanent successor. The intervals between reexaminations should be individualized depending on the severity of trauma, the expected type of complications and the age of the patient. Most complications are observed within the first year of the trauma. However, the follow-up evaluation of permanent teeth should continue until treatment of all complications is completed, or until a lost or extracted permanent tooth has been adequately replaced. It is important that the dentist and the other members of the dental team are well prepared to meet the many complex and challenging problems in the care of dental emergencies.

하악구치부에서 Bicon 임플란트에 의해 지지되는 고정성 국소의치의 광탄성 응력분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH BICON IMPLANTS ON MANDIBULAR POSTERIOR AREA)

  • 강종운;김난영;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.412-424
    • /
    • 2004
  • Statement of problem: Several prosthetic options are available for the restoration of multiple adjacent implants. A passively fitting prosthesis has been considered a prerequisite for the success and maintenance of osseointegration. Passivity is a particular concern with multiple implants because of documented inaccuracies in the casting and soldering process. One way to avoid this problem is to restore the implants individually, however, the restorations of individual adjacent impants requires careful adjustment of interproximal contacts. Purpose: The purpose of this study was to compare the stress distribution pattern and amount surrounding Bicon implants with individual crowns and splinted restorations. Material and method: A photoelastic model of a human partially edentulous left mandible with 3 Bicon implants($4{\times}11mm$) was fabricated. For non-splinted restorations, individual crowns were fabricated on 3 abutments ($4{\times}0.65mm,\;0^{\circ}$, 2.0 mm post, Bicon Inc., Boston, USA) After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal ($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m)$), and heavy($80{\mu}m$). Splinted 3-unit fixed partial dentures were fabricated and cemented to the model. Changes in stress distribution under simulated non-loaded and loaded conditions(7.5, 15, 30 lb) were analyzed with a circular polaricope. Results: 1. Stresses were distributed around the entire body of fin in Bicon implants. 2. Splinted restorations were useful for distribution of stress around implants especially with higher loads. 3. By increasing the contact tightness between the individually restored three implants, the stress increased in the coronal portion of implants. Conclusions: Ideal adjustment of the contact tightness was important to reduce the stresses around individually restored Bicon implants.

Laser 반사측정법을 이용한 전치부 후방 견인시 치조골 높이와 치근길이 감소에 따른 저항중심의 위치변화에 관한 연구 (A Study about the Change of Locations of the Center of Resistance According to the Decrease of Alveolar Bone Heights and Root Lengths during Anterior Teeth Retraction using the Laser Reflection Technique)

  • 민영규;황충주
    • 대한치과교정학회지
    • /
    • 제29권2호
    • /
    • pp.165-181
    • /
    • 1999
  • 교정치료시 치아와 주위조직의 부작용을 최소로 하면서 최대의 치료결과를 얻기 위해서는 치료역학을 각 환자의 치아 및 주위 해부학적 환경에 맞도록 개인화 시켜야한다. 특히 성인 교정시 문제되기 쉬운 치근흡수 또는 치주질환으로 인한 치조골 손실로 인하여 치관/치근 비율이 변했을 때 치아의 저항중심위치의 변화와 관련된 생역학적 반응의 차이에 주의하여야 한다. 본 연구에서는 정상 치주조직뿐만 아니라 다양한 비정상적 치주 및 치아상태에서 치관/치근 비율이 변하였을 때 일정한 교정력하에서의 치아의 초기이동 양상을 연구하기 위하여, 성인의 인체 건조 두개골 및 하악골상에서 laser 반사측정법 및 lever and pulley force applicator와 photodetector를 이용하여, 상악 6전치군을 대상으로는 치조골높이를 각각의 치아에 대하여 2mm씩 총 8mm까지 감소시켰고, 하악 6전치군을 대상으로는 치근길이를 각각의 치아에 대하여 2mm씩 총6mm까지 감소시키면서, 이렇게 다양하게 정량화된 변수들 하에서 상하악6전치군의 저항중심의 위치변화를 연구한 결과 다음과 같은 결론을 얻었다. 1. 초기상태에서 상악 6전치군의 초기이동시의 저항중심점의 위치는 6전치 전체 평균치아 치근의 치경부(CEJ)로부터 치근첨 방향으로 약 $42.4\%$되는 위치에 있었으며, 각 치아의 치조골의 높이가 감소할수록 저항중심점은 치근첨방향으로 약 $76.7\%$되는 부위까지 이동하였다. 2. 상악 6전치군에서 저항중심점의 6전치 전체 평균 치조정으로부터의 거리는 치조골의 감소와 함께 지속적으로 감소하였으나, 치조골내의 평균 치근의 길이에 대한 비율은 치조골의 감소에 상관없이 약 $33\%$내외에서 비교적 일정하였다. 3. 초기상태에서 하악 6전치군의 초기이동시의 저항중심점의 위치는 6전치 전체 평균치아 치근의 CEJ로부터 치근첨방향으로 약 $43\%$되는 위치에 있었으며, 각 치아의 치근의 길이가 감소할수록 이 비율은 약 $54\%$까지 증가하였다. 그러나 CEJ로부터 저항중심점까지의 거리는 5.3mm전후로부터 3.3mm내외까지 감소하여 치근의 길이가 감소할수록 저항중심점이 CEJ방향으로 이동하였다. 4.치조골 또는 치근흡수시, 각각의 단위 흡수량에 따른 저항중심위치의 변화에 미치는 영향은 초기에는 치조골이 감소 될 때가 더 컸으나 전체 평균 치근길이의 중간부위에서의 영향은 비슷했다.

  • PDF

웹뷰어를 이용한 기공실과 진료실 측 간의 보철물 설계 형태의 공유: 증례 보고 (Web viewer for sharing of prosthesis design between laboratory and clinic: Case report)

  • 장성원;이호진;김소연;이두형
    • 대한치과보철학회지
    • /
    • 제60권3호
    • /
    • pp.276-282
    • /
    • 2022
  • 성공적인 보철 수복물을 제공하기 위해서는 치과의사와 치과기공사 간의 긴밀한 의사소통은 중요한 요소이다. 치과기공사와 의견 교환은 주로 기공의뢰서와 사진촬영의 형태로 이루어져 왔으나 정보 전달이 제한될 수 있다고 보고되었다. 현재는 디지털 기술에 기반을 둔 보철물 제작이 일반화됨에 따라 영상 객체를 웹상에 저장하고 모바일 브라우저를 통해 손쉽게 확인할 수 있게 되었다. 본 논문에서는 CAD 소프트웨어를 이용하여 보철물을 설계하고 웹뷰어를 통해 치과의사와 설계된 보철물을 검토하여 보철물의 설계를 개선한 증례들을 소개한다. 본 프로토콜을 통해 교합면 및 치관 형태, 대합치 치료, 치은측 치간 공극의 크기, 가공치 하방 형태 등을 개선할 수 있었다. 이러한 웹뷰어를 통한 보철물 설계를 3차원적으로 치과의사와 공유하고 토의하여 수정하는 과정은 구강내 조건의 다양성과 개별화된 요구를 반영하는 데 기여하여 기능적이고 심미적인 보철물을 제작하는 데 도움을 줄 수 있다.