• Title/Summary/Keyword: Individual unit

Search Result 791, Processing Time 0.029 seconds

Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption (에너지소비를 고려한 실내공기청정기의 풍량별 입자 청정화능력 분석)

  • Han, Bangwoo;Kang, Ji-Su;Kim, Hak-Joon;Kim, Yong-Jin;Won, Hyosig
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.139-147
    • /
    • 2013
  • The performances of indoor air cleaners including particle cleaning capacity and collection efficiency are usually tested at the condition of the maximum air flow rate of the air cleaners. However, the power consumption of the air cleaners is highly dependent on the air flow rate of the individual air cleaners. Therefore, there seems to be an optimized air flow rate for the air cleaning capacity considering power consumption. In this study, clean air delivery rate(or standard useful area as suggested room size) and power consumption have been investigated for different maximum air flow rates of 15 air cleaners and then compared those for different air flow rate modes of the individual 5 air cleaners selected from the 15 cleaners. For the maximum air flow rate conditions of 15 air cleansers, the power consumption per unit area was less related to the maximum air flow rate. However, for the different air flow rate modes of the selected 5 air cleaners, the lower power consumption per unit area was corresponding to the lower air flow rate mode of the individual air cleaners. When considering the operation time to the desired particle concentrations, there was an optimized one in the medium air flow rate modes for the individual air cleaners. Therefore, not only the maximum air flow rate but also lower air flow rates of individual air cleaners should be considered for estimating air cleaning capacity based on energy consumption per unit area.

A Study on the Application of Low-Rise and High-Density Multiple Dwelling Housing Model in Urban Individual Residential Area - Focused on Ui-dong Public Detached Housing Area - (도시단독주택지 저층고밀형 집합주택 모델의 적용에 관한 연구 - 우이동 국민주택단지를 대상으로 -)

  • Jun, Byung-Kweon
    • Journal of the Korean housing association
    • /
    • v.22 no.3
    • /
    • pp.101-111
    • /
    • 2011
  • This study was conducted to investigate the indiscriminate development occuring as a result of high-density land use per lot in residential areas of Seoul, which mainly consist of detached houses. The primary goals of this study were: (1) to suggest a block unit development method as an alternative architectural method of the current uniform development, in which high-rise and high-density apartments are usually built; and (2) to check the feasibility of the suggested method. Based on the analyses of the existing block composition types of residential areas, the prerequisite planning indices for applying a collective housing model were investigated. Subsequent to applying a collective housing type within each unit block, the collective housing model was analyzed. The results of the analyses showed that indiscriminate development was rampant in detached urban houses areas, and more than 70% of the buildings constructed before the 1980s needed re-development. The feasibility of the models was investigated depending on the models of low-rise and high-density collective housing, which utilize various block arrangements such as the court type, linear type, villa type, and composite type. The results of this study showed that the newly applied low-rise and highdensity multiple dwelling housing model in urban individual residential area significantly contributed to creating a good living environment in terms of both physical and psychological aspects.

A Study on the Homemakers' Housing Notion according to Unit Size in Apartment - focus on 20pyung∼50pyung - (공동주택 평형별 주부들의 주거관에 관한 조사연구 - 20평형대∼50평형대를 중심으로 -)

  • 장경수;김경순
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.116-124
    • /
    • 2003
  • The purpose of this study was provide basic data for homemakers' housing notion according to unit size in apartment. This study was conducted by questionnaires that concerning about middle class homemakers whom they lived in Bundang. The results of this study were as follows; 1) In research on the homemakers' general quality, 20pyung unit size was alike 30pyung unit size and 40pyung unit size was similar to 50pyung unit size. 2) Homemakers' perception according to unit size in apartment was various; (a) 20pyungㆍ30pyung unit size-effective household space for husbands' participation, more sports facilities, parking lot space etc. (b) 40pyungㆍ50pyung unit size-homemakers' individual room, ordering and variable unit plan etc. 3) In research on the homemakers' needs, each of unit size was analogous to storage, common facility, new design and new housing form etc.

A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit (실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

Development of Electronic Identification Unit Using RF (RF를 이용한 전자 개체 인식 장치 개발)

  • 조성인;류관희;안광재;김유용;유윤관
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.459-466
    • /
    • 2002
  • In Korea, a need of automatic dairy farm management system has been increased to lower production cost and to strengthen international competition. However, the present management system was mostly relied on foreign technologies and caused some problems in post management and after-sales services. Therefore, though there is a problem of price and quality at present, domestic technologies of the management system should be developed for the long run. This study was conducted to develop an electronic identification unit for an automatic dairy farm management system. The developed system was consisted of a tag, a reader, a switching circuit, and a personal computer. The tag attachable to each individual cow was developed to transmit individual radio frequency(RF) code into the air with modulation of ASK(amplitude shift keying). And the switching circuit was added to avoid confusion on reception and transmittance. The reader attached to a feeding device was developed to transmit activating signal periodically and to identify code of the individual tag when the tag was approached to the device. The reader was consisted of an active filter, a detecter, a comparator and a microcontroller. The test result was feasible enough to apply it for the automatic farm management system and the identified maximum distance was about 37cm.

Robust Unit Root Tests for a Panel TAR Model

  • Shin, Dong-Wan
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.1
    • /
    • pp.11-23
    • /
    • 2011
  • Robust unit root tests are developed for dynamic panels consisting of TAR processes. The test statistics are all based on diverse combinations of individual t-type tests for significance of TAR coefficients. Limiting null distributions are established. A Monte-Carlo experiment compares the proposed tests. The tests are applied to a panel data set of Canadian unemployment rates which show asymmetric features as well as having outliers.

Development of a Height Adjustment Method of Prefabricated Individual Footing for the Leveling of Unit Modular Structural System (유닛모듈러 건축구조물의 수평 정밀도 확보를 위한 Pre-Fab 독립기초 높이조절 공법 개발)

  • Jun, Young-hun;Kim, Kyoon-Tai;Chae, Myung-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.6
    • /
    • pp.631-639
    • /
    • 2015
  • In the unit modular construction, the unit module prefabricated in a factory with a high level of accuracy does not fit completely onto the ground-joint junction due to the low accuracy of the ground work. This difference in the level of accuracy can cause diverse problems, such as twisting the upper unit modules and loosening the connection between the module and the footing. On this background, the aim of this study is to develop a technique for adjusting the height of the prefabricated individual footing. To accomplish the aim, a height adjustment method using bolts and nuts is proposed, and a shop drawing and the construction sequence are also presented in this study. The structural safety is verified through a structure simulation. In the future, research will be conducted on a mock-up test of the height adjustment method developed in this study, and an analysis of economic feasibility will be performed in order to verify its constructability and usability.

Evaluation of the Combination of Methylprednisolone and Tranilast after Spinal Cord Injury in Rat Models

  • Mbori, Ngwayi James Reeves;Chuan, Xie Yun;Feng, Qiao Xiao;Alizada, Mujahid;Zhan, Jing
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.334-340
    • /
    • 2016
  • Objective : The aim of our study was to evaluate the neuroprotective functions of the combination therapy using methylprednisolone (MP) and tranilast (TR) after spinal cord injury (SCI) in adult rats. Methods : Spinal cord compression injury model was achieved using Yasargil aneurysm clip. Rats were divided into control group, MP group, TR group, and combination therapy group using TR and MP. Rat models were assessed for locomotor functional recovery using Basso, Beattie, and Bresnahan (BBB) score, spinal cord water content and myeloperoxidase (MPO) activity 24 hours post SCI, haematoxylin and eosin staining and glial fibrillary acid protein (GFAP) staining at 7 and 14 days post SCI. Results : The spinal cord water content and MPO activity in the combination therapy group was significantly lower than the control group and the individual therapy groups p<0.05. The combination therapy group had significantly higher BBB scores than control group and individual therapy groups (p<0.05). At one week after SCI, GFAP expression in the combination group was significantly lower than the control group (p<0.05) but there was no significant difference compared to the individual therapy groups (p>0.05). At 2 weeks after SCI there was a slight decrease in GFAP expression compared to the first week but the difference was not statistically significant (p>0.05), GFAP expression between the groups was not statistically significant p>0.05. Conclusion : Combining MP and TR is therapeutically more effective in improving functional recovery, inhibiting inflammation and glial scar formation after acute SCI.

Unit Nonrespondents in a Taiwan Telephone Survey

  • Chen, Kuang-hui
    • Asian Journal for Public Opinion Research
    • /
    • v.3 no.3
    • /
    • pp.111-130
    • /
    • 2016
  • Researchers have been perplexed by the issue of unit nonresponse since the beginning of practicing survey research and have been attentive to the causes that lead to the occurrence of unit nonresponse as well as the impact of unit nonresponse. However, because researchers have little to no information regarding unit nonrespondents, it is unlikely that they are able to examine the differences between participants and nonrespondents to estimate the loss of representativeness in the final sample compared with the target population. Therefore, the lack of information regarding the absentees complicates addressing the unit nonresponse bias in a satisfactory manner. Therefore, the purpose of this study was to determine the demographic characteristics and political attitudes of nonrespondents by relying on information provided by their spouses, which was obtained through a telephone survey conducted in Taiwan. It is found that demographic variables as well as political attitudes are related to the likelihood of an individual becoming a unit nonrespondent in telephone surveys.

Monitor Unit calculation through Excell program (Excell 프로그램을 통한 치료선량(M. U) 계산)

  • Lim, Guang-Chae;Cho, Eun-Ju;Cho, Sun-Hang
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 1999
  • Verifying the treatment value(Monitor Unit) unnecessarily involves too many simple and repetitive calculation processes, that is, individual computation process using the data(PDD value, Scp Factor, SSD Factor, Tray Factor) on the data book. We intend to minimize the time required to check the Monitor Unit through computerized calculation. Using $^{\ast}(multiplication)$, /(division), +(sum), if function, among others, which are present in the Excell program, MS office program, the Monitor Unit was obtainable through A/P value, Scp Factor and PDD value, Wedge Factor. From the verification of the computations of Monitor Unit for 60 patients previously treated, we were able to obtain an error rate of ${\pm}0.028MU$. Computerized calculation of the Monitor Unit could save the burden of Technologist.

  • PDF