• Title/Summary/Keyword: Indirect technique

Search Result 384, Processing Time 0.025 seconds

Simulation Techniques for Mid-Frequency Vibro-Acoustics Virtual Tools For Real Problems

  • Desmet, Wim;Pluymers, Bert;Atak, Onur;Bergen, Bart;Deckers, Elke;Huijssen, Koos;Van Genechten, Bert;Vergote, Karel;Vandepitte, Dirk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.49-49
    • /
    • 2010
  • The most commonly used numerical modelling techniques for acoustics and vibration are based on element based techniques, such as the nite element and boundary element method. Due to the huge computational eorts involved, the use of these deterministic techniques is practically restricted to low-frequency applications. For high-frequency modelling, probabilistic techniques such as SEA are well established. However, there is still a wide mid-frequency range, for which no adequate and mature prediction techniques are available. In this frequency range, the computational eorts of conventional element based techniques become prohibitively large, while the basic assumptions of the probabilistic techniques are not yet valid. In recent years, a vast amount of research has been initiated in a quest for an adequate solution for the current midfrequency problem. One family of research methods focuses on novel deterministic approaches with an enhanced convergence rate and computational eciency compared to the conventional element based methods in order to shift the practical frequency limitation towards the mid-frequency range. Amongst those techniques, a wave based prediction technique using an indirect Tretz approach is being developed at the K.U.Leuven - Noise and Vibration Research group. This paper starts with an outline of the major features of the mid-frequency modelling challenge and provides a short overview of the current research activities in response to this challenge. Next, the basic concepts of the wave based technique and its hybrid coupling with nite element schemes are described. Various validations on two- and threedimensional acoustic, elastic, poro-elastic and vibro-acoustic examples are given to illustrate the potential of the method and its benecial performance as compared to conventional element based methods. A closing part shares some views on the open issues and future research directions.

  • PDF

Comparative Diagnostic Studies on Serologic and Molecular Biological Tests Against Haemorrhagic Fever with Renal Syndrome (신증후출혈열 환자의 혈청학적 및 분자생물학적 진단 검사법 비교)

  • 우영대;문희주;배형준
    • Biomedical Science Letters
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2000
  • The etiologic agents of haemorrhagic fever with renal syndrome (HFRS) in Korea are Hantaan and Seoul virus in the genus Hantavirus, family Bunyaviridae. Antibody titers of sera from HFRS patients against Hantaan virus were measured by immunofluorescent antibody technique (IFAT), enzyme-linked immunosorbent assay (ELISA), high density composite particle agglutination (HDPA) and plaque reduction neutralization test (PRNI). PRNT and nested reverse transcriptase polymerase chain reaction (nested RT-PCR) was used for serotypic differentiation of Hantaviruses against Hantaan and Seoul virus. Eight doubtful HFRS patients showed higher fluorescent, IgG ELISA, agglutination and neutralizing antibody titer by IFAT, ELISA IgG, HDPA and PRNT, respectively Five out of them showed high IgM antibody titer by IgM capture ELISA against Hantaan virus, remarkably. Fifteen HFRS patients showed higher fluorescent antibody titer by IFAT. In PRNT, 12 out of them showed high neutralizing antibody titer against HTNV, 2 against SEOV and 1 against both viruses. In nested RT-PCR using serotype specific-primer, 3 out of them showed positive against HTNV and 1 against SEOV.

  • PDF

3D Inversion of Aeromagnetic Data In an Area of Geumsan (금산지구 항공 자력탐사 자료의 3차원 역산)

  • Ko, Kwang-Beom;You, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.2
    • /
    • pp.49-57
    • /
    • 2014
  • 3D magnetic inversion, based on the assemblage of 2D forward modeling and inversion as a practical technique to reflect the a priori information, was conducted to investigate the spatial distribution features of black-shale related and pyrometamorphic uranium deposit and several lithological units of Ogcheon Super Group in an area of Geumsan. By using the 3D visualization technique with suitable susceptibility interval and horizontal slice map, the spatial distribution of magnetic susceptibility corresponded to the black shale related uranium bearing lithological units, Black Slate member was well coincided with a information of uranium deposit. Also, even though it is indirect indicator for the detetction of uranium deposits interbedded in Gray Hornfels member, spatial susceptibility distribution which shows the south-east magnetic linearment corresponding to the Majeon-ri formation and Dark Gray Slate were matched well. From this investigation, we inferred that maximum depth extension which Black Slate member can be separately recognized with respect to adjacent Dark Gray Slate with strong magnetic susceptibility anomaly is about 150m with reference elevation level of 306m. In addition, Majeon-ri formation located south of Black Slate member revels relatively high magnetic susceptibility range but shows high spatial susceptibility fluctation. And, as an intrusive rocks, Jurassic Biotite Granite shows relatively low magnetic susceptibility characteristics. On the contrary, Cretaceous granite distributed in soutthern part of the study area shows the relatively high susceptibility distribution.

Studies on the Seroimmunodiagnosis of Parasitic Diseases (기생충질환(寄生蟲疾患)의 면역혈청학적(免疫血淸學的) 진단(診斷)에 관한 연구(硏究))

  • Rim, Han-Jong;Lee, Joon-Sang;Joo, Kyoung-Hwan;Eam, Kee-Seon;Chung, Myung-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.13 no.1
    • /
    • pp.41-59
    • /
    • 1988
  • In many of the helminthic infections, diagnosis is accomplished by the demonstration of the eggs or, occasionally the adult worms or their parts. Diagnosis can be made by the identification of larval stage obtained from stool or surgically extracted materials too. However some kinds of parasitic disease can not be diagnosed by above mentioned procedure alone. Brain cysticercosis, ectopic paragonimiasis, Capillaria hepatica infection in liver is a good example. In such a case, immunologic method would be helpful for the decision of physician. In this paper, immunologic tools such as indirect hemagglutination test, indirect fluorescent antibody test, circumoval precipitation test, ELISA, western blot were applied for the diagnosis of Clonorchis sinenisis, Cysticercosis and C. hepatica a infection and their efficacy was evaluated. The results obtained were as follows ; 1) In the diagnosis of clonorchiasis, ELISA revealed sensitiveity of 83.3%, but cross reaction against antibody of Paragonimus westermani and Taenia species were observed. For the identification of cross reaction and species specific band of Ag-Ab reaction, western blot was applied. 59Kd relative molecular weight and 21Kd band were identified as a Clonorchis sinensis specific band. OD values of ELISA performed with sera of 18 months after praziquantel treatment decreased to half level compared to that of before treatment. Negative conversion rate of ELISA after 18 months of treatment was 60%. 2) In the diagnosis of cysticercosis, IFAT disclosed 95.8%(23/24) of sensitivity and reaction was most strongly occurred in inner membrane. ELISA revealed 90.0% (36/40) of sensitivity, but cross reaction was observed in both technique. In western blot, 91, 63 and 21Kd Mw bands were identified as a strongly positive band. Among them 63Kd band showed positive reaction against almost all sera of cysticercosis patient. 3) Circumoval precipitation, ELISA, IFAT, showed 85.0% of sensitivity in the diagnosis of C. hepatica infection in rat. The antigenic localities were inner membrane of sectioned egg antigen on the prectipitates around the mucoid plugs which were induced by circumoval precipitation reaction. Sera from rats infected with 2000eggs were collected periodically to observe the changing patterns of antibody titers by IFAT and ELISA, which showed that high titers were detected at weeks 3 and 5, then gradually declined through weeks 9until to negatively converted at weeks 13.

  • PDF

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

Statistical Analysis of Water Flow and Water Quality Data in the Imjin River Basin for Total Pollutant Load Management (임진강 유역 오염물질 총량관리를 위한 유량-수질 자료의 통계분석)

  • Cho, Yong-Chul;Choi, Hyeon-Mi;Lee, Young Joon;Ryu, Ingu;Lee, Myung-Gu;Gu, Donghoi;Choi, Kyungwan;Yu, Soonju
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.4
    • /
    • pp.353-366
    • /
    • 2018
  • The purpose of this study was assessment the quality of water by using the statistical analysis technique of the Water flow and water quality from January 2012 to December 2016 at the unit basin for total pollutant load management system (TPLMS) in the Imjin River. Water flow and water quality were monitored at an average of 8 day intervals, 11 parameters were used for correlation analysis, principal component analysis (PCA), factor analysis (FA), and cluster analysis (CA). The Hierarchical CA was classified into three according to the change of space, such as natural rivers, urban rivers, point with large influence of point pollution source, it was found that the type of contamination source the similarity of water quality affected the classification of cluster. Using one-way analysis of variance (ANOVA) and post-hoc Analysis, there were statistically significant differences between mean values among the clusters. Correlation analysis showed the correlation coefficient between $COD_{Mn}$ and TOC was 0.951 (p<0.01) and the correlation was statistically significantly higher. According to the result PCA and FA, 3 principal components can explaining 72% of the total variations in water quality characteristics and main factor was EC, $BOD_5$, $COD_{Mn}$, TN, TP and TOC indirect indicators of organic matter and nutrients were influenced. This study presented the regression equation obtained by applying the factor scores to the multiple linear regression analysis and concluded that the management Indirect indicators of organic matter and nutrients is important for water quality management in the Imjin River basin.

Clinical Characeristics of Intracordal Cysts (성대낭종의 임상적 특성)

  • Hong, Ki-Hwan;Park, Jung-Hoon;Kim, Won;Kim, Chang-Hyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.2
    • /
    • pp.164-169
    • /
    • 1999
  • Background and Objectives : The intracordal cysts are more increasingly diagnosed and treated due to advanced laryngeal stroboscopy and laryngeal microsurgical technique. The intracordal cysts are frequently misdiagnosed as vocal polyp or nodule The purpose of this study is to evaluate clinical features of intracordal cysts. Materials and Methods : In the present series, 83 cases of the intracordal cysts treated with laryngeal microsurgery are reported. The intracordal cysts are diagnosed preoperatively with indirect laryngoscopy, laryngeal endoscopy, laryngeal stroboscopy and confirmed with laryngeal microsurgical findings and biopsies. Results : Intracordal cysts are 83 of 1900 patients treated with laryngeal microsurgery(4.4%)-ductal cysts are 56 cases and epidermoid cysts are 27 cases. Intracordal cysts are more frequent in women, forties and the frequent site is an anterior third of the true vocal cord. With the indirect laryngoscopic examination, the ductal cysts are frequently misdiagnosed as vocal polyps or nodules but the epidermoid cysts are relatively easily diagnosed. The etiologic factors of the intracordal cysts are suspected as voice abuse and upper respiratory infection. The degree of postoperative voice satisfaction is similar to that of the vocal polyps. Conclusion : Intracordal cysts are frequently misdiagnosed as polyps or nodules, therefore preoperative stroboscopic findings and laryngeal microsurgical findings is important. An ideal treatment is to enucleate the cysts avoiding rupture of cyst and injury of lamina propria of the vocal cord.

  • PDF

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.

DIMENSIONAL ACCURACY OF EPOXY RESINS AND THEIR COMPATIBILITY WITH IMPRESSION MATERIALS (EPOXY RESIN의 정확도와 인상재와의 친화성에 관한 연구)

  • Chang, Su-Kyoung;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.383-394
    • /
    • 1999
  • The indirect technique for making cast restoration requires that dies be as accurate and durable as possible. Currently, stone is the most commonly used material for die. However, it has some problems such as the weakness in its strength and low abrasion resistance. Recently, epoxy resin die systems have become available. The purpose of this study was to examine two commercially available resin die systems and evaluate some characteristics for their clinical performance. This study evaluated the dimensional accuracy of epoxy resins and their wettability with impression materials. In this study, the first experiment was about dimensional accuracy of different die materials. The master model was made of stainless steel. 10 models were made of two epoxy resins (Die-epoxy, Tri-epoxy) and a die stone (Fujirock) each. Occlusal diameter (Dimension I), occluso-gingival height (Dimension II), and interabutment distance (Dimension III) were measured in each model. Next, the contact angles of die materials with impression materials were observed. The blocks were made of polyether, hydrophilic additional silicone, polysulfide impression materials. By drop-ping the same amount (0.05ml) of Tri-epoxy, Die-epoxy, and die stone on the blocks, 10 samples of each die material were made. After setting of materials, the contact angles were measured. The results of this study were as follows. 1. The expansion of stone die and the shrinkage of resin dies in occlusal diameter were observed, and stone and Tri-epoxy were expanded and Die-epoxy was shrinked in occluso-gingival height. There was little change among materials in interabutment distance (p<0.05). 2. In comparison with the master model Tri-epoxy had the least variation in measurement of the three die systems examined. Die-epoxy was next, and die stone showed the greatest variation. 3. The compatibility of die stone for polyether, hydrophilic additional silicone, polysulfide decreased in order, wherease epoxy materials had the decreased compatibility for polyether and polysulnde, hydrophilic additional silicone in order. It was not statistically different between polyether and polysulfide (p<0.05). 4. The contact angles of Tri-epoxy, Die-epoxy, die stone were getting bigger in order.

  • PDF

Studies on Erythropoietin Bioassay Method (Erythropoietin 검사법(檢査法)에 관(關)한 연구(硏究))

  • Cho, Kyoung-Sam;Ro, Heung-Kyu;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.2
    • /
    • pp.39-46
    • /
    • 1975
  • It is the purpose of this paper to design the most preferable method of erythropoietin bioassay in Korea. Bioassay utilizing polycythemic mice are currently in general use for the indirect determination of erythropoietin. Assay animals are usually prepared either by transfusion or by exposure to reduced oxygen tension in specially constructed chamber. We prepared the polycythemic, mice by the specially constructed hypobaric chamber. We observed weights and hematocrits of the mice in the hypobaric chamber, then hematocrits and 72 hours $^{59}Fe$ red cell upatke ratio of the polycythemic mice induced by hypoxia after removal from the hypobaric chamber. We designed the method of erythropoietin bioassay according to the results obtained by above experiments. Then we measured the 72 hours $^{59}Fe$ red cell uptake ratio of the polycythemic mice with normal saline, normal plasma and anemic plasma according to the method we designed. The results are followed: 1. The hematocrits of the mice in hypobaric chamber increased to 74% in 14 days It is preferable to maintain the pressure of the chamber to 400mmHg for first 4 days then 300mmHg for last 10 days to reduce the death rate and time consuming in hypobaric chamber. 2. After removal from the hypobaric chamber, the 72 hours $^{59}Fe$ red cell uptake ratio decreased rapidly and maintained the lowest level from the fourth day to tenth day. 3. We design the method of erythropoietin bioassay according to the results of above experiment and to the half life of erythropoietin. 4. The Korean product S9Fe is mixture of $^{59}Fe\;and\;^{55}Fe$. And the $^{59}Fe$ red cell uptake ratio in normal mice was far less with Korean product $^{59}Fe$ than with pure $^{59}Fe$ of foreign product. So it is desirable to use pure $^{59}Fe$ in this method of erythropoietin bioassay. 5. Considering the cost, the technique, the time consuming and the sensitivity it is the most preferable method of erythropoietin bioassay in Korea using hypobaric chamber to induce the polycythemia.

  • PDF