PUID개념을 도입한 Elevator 표시기류 개발에 관한 연구 (A Study For Elevator Indicator Design By Product-User Interface Design Concept)

  • 정도성;박윤규
    • 한국디자인학회:학술대회논문집
    • /
    • 한국디자인학회 1999년도 춘계 학술발표대회 논문집
    • /
    • pp.2-3
    • /
    • 1999
  • 근래에 들어 사용자를 중심으로 한 제품개발 전개 활발히 진행되어지고 있다. 사용자 중심의 디자인 중에서도 UI(User-Interface '이하 GUI')분야는 컴퓨터의 발전 속도에 의해 급속히 전파되고 있다. 하지만 디자인분야의 Ul는 GUI(Graphical User-Interface '이하GUI')분야에만 기형적 발전이 이루어지고 있는 것이다. (중략)

  • PDF

엘리베이터 설치 작업용 시스템 비계의 구조 성능 평가 (Structural Performance Evaluation of System Scaffolding for Elevator Installation Work)

  • 황종문;이기열
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.61-68
    • /
    • 2023
  • This study performed a structural performance evaluation of a system scaffolding for elevator installation work developed in previous studies. The structural performance was evaluated via a structural test conducted to apply the working load specified in the design standard. The deflection of the horizontal member and the stress of each member constituting the system scaffolding were measured. Consequently, the structural safety evaluation including structural behavior and required performance was performed using the deflection and stresses measured from the structural test. The structural test and safety evaluation results based on the heavy working load corresponding to the design load indicated that the deflection, which is the performance criterion of the horizontal member, did not exceed the allowable value. Further, each member's stress, which is a safety evaluation indicator, did not exceed the allowable strength for both horizontal and vertical members with bending behavior and fordable bracing with tensile behavior, while also satisfying the required safety factor. In addition, the results confirmed the safety against deformation, partial damage, and destruction owing to excessive and maximum load. Therefore, the system scaffolding developed in this study satisfies both the structural performance and safety required by the design standards; thus, it can be applied to elevator installation work sites.

주거용 아파트 엘리베이터의 미생물 오염도와 영향요인 조사 (Research on Bacterial Contamination Levels in Apartment Tower Elevators)

  • 심원보;서주희;이채원;정명진;김정숙;김형갑;정덕화
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.456-464
    • /
    • 2013
  • Objectives: The aim of this study was to investigate the microbial contamination levels in elevators in apartment buildings and to provide information on such microbial contamination. Methods: A total of 144 samples, including from the exterior buttons, interior buttons, elevator handrails, walls, ventilators and airborne bacteria were collected in the morning and afternoon from July to August 2013 for six different elevators. The samples were used to detect sanitary indicator bacteria (total bacteria, coliform, and Escherichia coli), pathogenic bacteria (E. coli O157, L. monocytogenes, Salmonella spp., B. cereus, S. aureus) and fungi. Results: Contamination levels of total bacteria were 0.3-3.8 and 0.0-2.4 log CFU/100 $cm^2$ in the morning and afternoon, respectively. In the case of coliform bacteria, the levels were 0.0-3.7 log CFU/100 $cm^2$ in the morning and 0.0-0.3 log CFU/100 $cm^2$ in the afternoon. However, E. coli was not detected among all samples. Bacillus cereus, pathogenic bacteria, was only detected in 13 (11%) among 144 samples. E. coli O157, L. monocytogenes, Salmonella spp. and S. aureus were not detected among all samples. Comparing the samples collected in the morning and afternoon, we could confirm that the samples in the afternoon were cleaner. Conclusions: This study indicates that the samples in the afternoon were cleaner because these samples were collected following routine cleaning. Also, the levels of contamination in the elevators were low and the sanitary conditions were comparatively well-managed. Therefore it is deemed necessary for elevators be cleaned regularly to provide good conditions for people using elevators.