• Title/Summary/Keyword: Index Bond

Search Result 175, Processing Time 0.026 seconds

Properties and pozzolanic reaction degree of tuff in cement-based composite

  • Yu, Lehua;Zhou, Shuangxi;Deng, Wenwu
    • Advances in concrete construction
    • /
    • v.3 no.1
    • /
    • pp.71-90
    • /
    • 2015
  • In order to investigate the feasibility and advantage of tuff used as pozzolan in cement-based composite, the representative specimens of tuff were collected, and their chemical compositions, proportion of vitreous phase, mineral species, and rock structure were measured by chemical composition analysis, petrographic analysis, and XRD. Pozzolanic activity strength index of tuff was tested by the ratio of the compression strength of the tuff/cement mortar to that of a control cement mortar. Pozzolanic reaction degree, and the contents of CH and bond water in the tuff/cement paste were determined by selective hydrochloric acid dissolution, and DSC-TG, respectively. The tuffs were demonstrated to be qualified supplementary binding material in cement-based composite according to relevant standards. The tuffs possessed abundant $SiO_2+Al_2O_3$ on chemical composition and plentiful content of amorphous phase on rock texture. The pozzolanic reaction degrees of the tuffs in the tuff/cement pastes were gradually increased with prolongation of curing time. The consistency of CH consumption and pozzolanic reaction degree was revealed. Variation of the pozzolanic reaction degree was enhanced with the bond water content and relationship between them appeared to satisfy an approximating linear law. The fitting linear regression equation can be applied to mutual conversion between pozzolanic reaction degree and bond water content.

The Effect of Surface Treat`ment on Bond Strength of Polycarbonate Bracket (폴리카보네이트 브라켓 부착 시 결합강도 증진을 위한 표면처리 효과)

  • Kim, Seok-Pil;Kim, Nyeon-Kyeong;Lee, Hyun-Jung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • Objective: The purpose of this study was to evaluate whether the bond strength of polycarbonate brackets can be increased through surface treatment. Methods: One hundred polycarbonate brackets (Alice) were bonded to bovine incisors with light-cured adhesive. The bracket bases were treated with one of three methods; sandblasting, plastic conditioner application, and combined treatment with sandblasting and plastic conditioner. The brackets without any suraace treatment served as the control. The shear bond strength was tested with a universal testing machine, and failure pattern was assessed with the adhesive remnant index. Results: The shear bond strength in all experimental groups was higher than that of the control group (p < 0.001). The group treated with plastic conditioner after sandblasting showed statistically higher shear bond strength than the sandblasting only group to (p < 0.05). The group treated with plastic conditioner after sandblasting showed higher shear bond strength than plastic conditioner only group, but the difference was not statistically significant. Conclusion: The above results suggest that the surface treatments of polycarbonate bracket is mandatory to improve bond strength, and the most effective method is an application of plastic conditioner after sandblasting.

Shear bond strength between gold alloy and orthodontic metal bracket using light emitting diode curing light (Light emitting diode를 이용한 광중합 시 금합금과 교정용 금속 브라켓의 전단접착강도)

  • Jung, Min-Ho;Chung, Shin-Hye;Shon, Won-Jun
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • Objective: The need to bond orthodontic brackets onto various alloys has increased because of the increasing demand for adult orthodontic treatment. This study tried to evaluate the shear bond strength between gold alloy and metal bracket using light emitting diode (LED) light curing after metal primer and silicoating surface conditioning. Methods: Half of the type III gold alloy plates were treated with sandblasting with aluminum oxide and metal primer containing 4-META. the other half were treated with silica and silane. Metal brackets were bonded with Transbond XT light curing adhesive on these plates and shear bond strength were evaluated 1 hour, 6 hours, and 24 hours later. The differences of shear bond strength between groups were evaluated with two-way ANOVA. Results: The results showed higher bond strength in the silicoating group and a tendency of bond strength increase over time. Conclusions: When using LED curing lights for metal bracket bonding to alloy surfaces, long curing time and silicoating can produce a reliable bonding strength.

The Theoretical Studies for the (Molecular Connectivity법에 의하여 발암성 Benzenoid 탄화수소의)

  • Ui Rak Kim;Jong Guk Eun;Myung-Jae Lee;Kim Sang Hae
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.153-161
    • /
    • 1987
  • The carcinogenicity of benzenoid hydrocarbons apparently depends strongly on the topological nature of the molecule. The existance of certain regions in the structure which are known propensity of benzenoid hydrocarbons to be carcinogenic. We try to identify the correlation between the number of potentially carcinogenic bay region in each of them and the quantity of Molecular Connectivity Index for 81 benzenoid hydrocarbons. Results indicate an excellent linear correlation between the number of bay region and the quantity of molecular connectivity index except the molecular containing single bond in their structure.

  • PDF

Extended Huckel Calculations of the Effect of Sulfenyl, Sulfinyl and Sulfonyl Groups on the Reactivity of Halides in $S-N2$ Reactions (할라이드의 $S_N2$ 형 반응성에 미치는 술페닐, 술피닐 및 술포닐기의 효과에 대한 확장 Huckel 계산)

  • Ui Rak Kim;Kyu Yong Lee;Sun Ho Bai;Ikchoon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.3-7
    • /
    • 1974
  • Extended Huckel calculations have been carried out to study the effect of sulfenyl, sulfinyl and sulfonyl groups on the reactivity of halides in $S-N2$ reactions. Results indicate that the most reasonable reactivity index is that based on the Frontier electron for the bond formation process.

  • PDF

A Change of Shear Bond Strength of Orthodontic Resin Adhesives under Water Immersion (침수후 시간에 따른 교정용 레진접착제의 전단결합강도 변화)

  • Lee, Je-Jun;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.783-789
    • /
    • 1998
  • The purpose of this study was to evaluate the changes of shear bond strengths and failure patterns in orthodontic resin adhesives according to the water immersion time. Metal brackets were bonded to the specimens involving the premolars with chemical-cured($Concise^{\circledR}$) and light-cured($Transbond^{\circledR}$) adhesives. The shear bond strength was measured on universal testing machine and the failure patterns were assessed with the adhesive remnant index(ARI) after storage in distilled water at $37^{\circ}C$ for 1 day, 1 week and 1, 3, and 6 months, respectively. The results were as follows. 1. The shear bond strengths at the 6 month in both Concise and Transbond were significantly higher than those at the 1 day, 1 week and 1 month(p<0.05). There were positive correlations between shear bond strength and water immersion time in both Concise and Transbond(P<0.01). 2. There were no significant differences in shear bond strength between Concise and Transbond. 3. The brackets were failed primarily at the bracket base-adhesive interface and there was no significant difference in the incidence of ARI scores according to the water immersion time.

  • PDF

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE THICKNESS OF RESIN BASE IN BRACKET BONDING (브라켓 부착시 레진 베이스의 두께에 따른 전단결합강도와 파절양상에 관한 연구)

  • Kim, Jae-Hyuk;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.659-668
    • /
    • 1998
  • The purpose of this study was to evaluate the possibility of the decrease of bond strength due to increased thickness of resin base in indirect bracket bonding technique. Metal brackets were bonded to the resin blocks involving bovine lower incisors and the thickness of resin bases was increased by increments of 0.5 mm from 0.0 mm to 2.0 mm. They were divided into two groups, one group is that the thickness of resin base was increased but the loading point from the tooth surface was maintained constantly, the other group is that the loading point from the tooth surface and the resin base thickness were increased concomitantly. The shear bond strength was tested on universal testing machine and the failure patterns were assessed with the adhesive remnant index(ARI). The results were as follows: 1. When the distance from the tooth surface to the loading point was maintained constantly, shear bond strength was increased significantly according to the decrease of distance from the bracket base to the loading point and the increase of resin base thickness. 2. When the distance from the tooth surface to the loading point and the resin base thickness were increased concomitantly, shear bond strength was decreased according to the increase of resin base thickness but significant differences were ignorable. 3. There were no significant differences in ARI scores according to the change in the thickness of resin base. The results of the present study indicated that shear bond strength was not much affected by the thickness of resin base, whereas was decreased according to the increase of distance from bracket base to the loading point.

  • PDF

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE MATERIAL OF RESIN BASE IN INDIRECT BRACKET BONDING (브라켓 간접부착시 레진 베이스의 재료에 따른 전단결합강도와 파절양상 비교)

  • Jeon, Man-Bae;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.277-284
    • /
    • 1998
  • The purpose of this study was to evaluate the propriety of making use of the light-cured resin base in indirect bracket bonding technique by study of shear bond strength and failure patterns according to the material of resin base. Metal brackets were bonded to the stone models of specimens involving bovine lower incisor with chemical-cured(Excel), light-cured(Light-Bond) and thermal-cured(Therma-Cure) resin. They were transferred to the specimens and bonded using sealant. The shear bond strength was tested on Instron. After bracket removal, the bracket base was examined and assessed with the adhesive remnant index(ARI). The results were as follows : 1. No significant differences in shear bond strength were found among the three groups (P>0.05). 2. No significant differences in ARI score were found among the three groups (P>0.05). The above results suggest that light-cured resin base in addition to chemical-cured and thermal-cured resin bases is useful in the indirect bonding technique.

  • PDF

Effects of Thermal and Mechanical Fatigue Stress on Bond Strength in Bracket Base Configurations (열적, 기계적 피로응력이 교정용 브라켓의 결합강도에 미치는 영향)

  • Kim, Jong-Ghee;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.625-642
    • /
    • 2000
  • The purpose of this study is to evaluate the effects of mechanical and thermal fatigue stress on the shear, tensile and shear-tensile combined bond strengths(SBS, TBS, CBS) in various orthodontic brackets bonded to human premolars with chemically cured adhesive(Ortho-one, Bisco, USA). Five types of commercially available metal brackets with various bracket base configurations of Photoetched base(Tomy, Japan), Non-Etched Foil Mesh base(Dentaurum, Germany), Micro-Etched Foil Mesh base(Ortho Organizers, USA), Chessboard base(Daesung, Korea), and Integral base(3M Unitek, USA) were used. Samples were divided into 3 groups, the first group was acted with shear-tensile combined loads($45^{\circ}$) of 200g for 4 weeks(mechanical fatigue stress), the second group was subjected to the 5,000 thermocycles of 15 second dwell time each in $5^{\circ}C\;and\;55^{\circ}C$ baths(thermal fatigue stress), and the third group was the control. Bond strengths were measured at the crosshead speed of 0.5mm/min. The cross-section of bracket base/adhesive interface and the fracture surface were examined with the stereoscope and the scanning electron microscope. The resin remnant on bracket base surface was assessed by ART(Adhesive Remnant Index). The obtained results were summarized as follows, 1. In static bond strength, Photoetched base bracket showed the maximum bond strength and Integral base bracket showed the minimum bond strength(p<0.05). In all brackets, shear bond strength(SBS) was in the greatest value and shear-tensile combined strength(CBS) was in the least value(p<0.05). 2. After mechanical fatigue test, Photoetched base bracket showed the maximum bond strength and Integral base bracket showed the minimum bond strength(p<0.05). In Photoetched base bracket and Micro-Etched Foil Mesh base bracket, shear bond strength(SBS), tensile bond strength(TBS) and shear-tensile combined strength(CBS) were decreased after mechanical fatigue test(p

  • PDF

The Study of Milling Properties for Optimization of Treatment and Recycling of Converter Slag (제강슬래그 처리 및 재활용의 최적화를 위한 분쇄 특성에 관한 연구)

  • Kuh, Sung-Eun;Hwang, Kyoung-Jin;Kim, Dong-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1139-1148
    • /
    • 2000
  • To treat and recycle a large quantity of converter slag. the milling properties of -14/ +24 mesh-sized slag has been considered. The optimal conditions in milling process were investigated for producing powder-type slag and the required consumption was derived for the economical grinding. The characteristics of milling processes were studied in the variation of the rotational speed, milling time, filling ratio of ball, and size and amount of feed. The grinding efficiency was also examined. The optimal rotational speed in this experimental condition was observed to be the value of 79% of critical speed. The extent of grinding was increased with increasing the grinding time. but the efficiency of milling was decreased with the time. 50% ball filling was shown to have the optimal grinding effect, and less amount and small-sized feed made the milling efficiency high. As the result, using Bond's equation, power required for efficient milling was considered and the highest value was observed in the condition of high grinding time and optimal rotational speed.

  • PDF