• Title/Summary/Keyword: Independent Operation

Search Result 858, Processing Time 0.035 seconds

A study on the Estimation Function of the Operating Cost for an Urban Railway (with a focus on Medium-sized Rapid Transit) (도시철도 운영비용 추정함수개발에 관한 연구 (중간규모 도시철도를 중심으로))

  • Chung, Su Young;Lee, Won Young
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.4
    • /
    • pp.318-330
    • /
    • 2013
  • It is necessary to estimate the operating cost for constructing an urban railway system. The present study was thus carried out to develop an estimation function of the operating cost for a MRT(Medium-sized Rapid Transit) system. We selected seven independent variables that could influence the operating cost: the rolling stocks, the number of trains in operation, the length of the lines, the number of stations, the number of passengers per day, the frequency of train operation, and the number of depots. We performed a multiple regression using Excel. Three types of regression functions were thereupon developed. All of them proved to be appropriate after comparing the results of the estimated cost. It will therefore be possible to use one of these three types, depending on the assumptions of the independent variables.

Development and Testing of Satellite Operation System for Korea Multipurpose Satellite-I

  • Mo, Hee-Sook;Lee, Ho-Jin;Lee, Seong-Pal
    • ETRI Journal
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • The Satellite Operation System (SOS) has been developed for a low earth orbiting remote sensing satellite, Korea Multipurpose Satellite-I, to monitor and control the spacecraft as well as to perform the mission operation. SOS was designed to operate on UNIX in the HP workstations. In the design of SOS, flexibility, reliability, expandability and interoperability were the main objectives. In order to achieve these objectives, a CASE tool, a database management system, consultative committee for space data systems recommendation, and a real-time distributed processing middle-ware have been integrated into the system. A database driven structure was adopted as the baseline architecture for a generic machine-independent, mission specific database. Also a logical address based inter-process communication scheme was introduced for a distributed allocation of the network resources. Specifically, a hotstandby redundancy scheme was highlighted in the design seeking for higher system reliability and uninterrupted service required in a real-time fashion during the satellite passes. Through various tests, SOS had been verified its functional, performance, and inter-face requirements. Design, implementation, and testing of the SOS for KOMPSAT-I is presented in this paper.

  • PDF

A Study on Analysis of Defects cause for Rotor in the High Voltage Induction Motors (고압유도전동기의 회전자 결함요인 분석에 관한 연구)

  • Lee, Eun-Chun;Byun, Doo-gyoon;Chae, Ji-Seog;Byun, Ill-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.655-656
    • /
    • 2015
  • In this paper, diagnosis for 85 high voltage induction motors which have operated for more than 20 years in 18 wide area water supply offices were applied and the results of diagnosis were analysed. Furthermore, main factors that would be affecting rotor defects were selected and correlations between dependent variables which was magnitude for sideband frequency on current during operation and independent variables such as starting characteristic, operating time, number of operation, load factor, maker, rotation speed, capacity were analysed. It was clear that factors including starting characteristic, number of operation, maker, rotation speed caused break by correlation analysis. From this, regression equation was deduced through regression analysis. Based on suggested regression equation, it is applied usefully that we can estimate the condition of rotor without onsite diagnosis and plan the schedule of diagnosis.

  • PDF

Evaluation of the Menus of Free Meal Service Centers for Home-bound Elderly (재가노인들을 위한 무료급식소의 식단 평가)

  • Han, Kyung-Hee;Park, Jung-Sook;Choi, Mee-Sook;Chung, Soon-Dool;Chai, In-Sook
    • Journal of the Korean Society of Food Culture
    • /
    • v.17 no.5
    • /
    • pp.584-593
    • /
    • 2002
  • The purpose of this study was to evaluate the diet quality of the menus delivered by 17 free meal service centers for the low-income home-bound elderly in Chung- cheong buk-Do. Statistical data analysis was compleleted using the SPSS package program for descriptive analysis, T-test, and ANOVA. The meals offered by free meal service centers were not met the 1/3 recommended dietary allowances in calcium and vitamin $B_2$. There were significant differences between dependent variables(nutrient content, nutrient density, nutrient deficiency, NAR, MAR, food group intake patterns) and independent variables (operation type, operation status, operation period, nutritionist, food cost).

Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region (전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.

Shot -term Operation Scheduling Using Fuzzy Theory on Cogeneration Systems Connected with Auxiliary Equipments (각종 보조설비와 연계된 열병합발전시스템에서 퍼지이론을 적용한 단기운전계획수립)

  • Lee, Jong-Beom;Jung, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.553-555
    • /
    • 1995
  • This paper presents the optimal short-term operation scheduling by using on cogeneration systems connected with auxiliary equipments. Simulation is performed in case of the bottomming cycle which generates the demand heat preferentially. Heat storage tank, electricity charger, auxiliary boiler and independent generator are considered as auxiliary equipments connected to cogeneration systems. The results of simulation show the auxiliary equipments can be effeciently operated in case of the bottomming cycle by modeling proposed in this paper. The effectiveness of operation scheduling gained by application of fuzzy theory is evaluated by detailed comparison and investigation of the simulation results.

  • PDF

The Parallel Operation of AC to DC PWM Converters for a High Speed Railway Train (고속전철용 입력 AC/DC PWM 컨버터의 병령운전)

  • Ryu, Hong-Je;U, Myeong-Ho;Kim, Jong-Su;Im, Geun-Hui;Won, Chung-Yeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.4
    • /
    • pp.272-281
    • /
    • 2000
  • This paper deals with the parallel operation of several numbers of PWM converters for a high speed railway train application. Several considerations are made to reduce the transformer interaction which can cause a current control problem in severe case. Also, in this paper, novel control strategy is proposed to achieve a harmonic free primary-side current control under a light load condition using one current sensor independent of the number of converters. In addition, the modified predictive current controller, which is suitable to a digital current controller with a relatively large sampling period, is used. Finally, to verify the system validity, digital control system with TMS320C44 micro-processor and small scale simulator are made and tested.

  • PDF

Evaluation of KOMPSAT-1 Orbit Determination Accuracy

  • Kim, Hae-Dong;Choi, Hae-Jin;Kim, Eun-kyou
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.588-590
    • /
    • 2003
  • For the normal operations, KOMPSAT-1 orbits are determined using GPS navigation solutions data such as position and velocity vectors. Currently, the accuracy of GPS navigation solution data is generally known as on the order of 10~30 m with the removal of S/A. In this paper, an estimate of the current orbit determination accuracy for the KOMPSAT-1 is given. For the evaluation of orbit determination accuracy, the orbit overlap comparison is used since no independent orbits of comparable accuracy are available for comparison. As a result, It is shown that the orbit accuracy is on the order of 5 m RMS with 4 hrs arc overlap for the 30 hr arc.

  • PDF

Development of Multi-Reservoir System Operation Rule Curves for Hydropower Maximization in the Nam Ngum River Basin of Lao PDR (라오스 남능강 유역 다중 저수지 시스템의 최적 수력발전 운영규정 곡선 개발)

  • Lee, Hyun-Jae;Jang, Woong-Chul;Lee, Il-Ju;Lee, Jin-Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.803-814
    • /
    • 2022
  • The Lao government is continuously developing hydro-power dams in addition to the existing eight power plants in the Nam Ngum River basin and is expanding the power capacity of the existing power plants to meet the expected increase in electricity demand. Accordingly, the Lao government has requested an update on the existing reservoir operating rule curve in order to run the power plants efficiently. To this end, this study reviewed the current independent operating system as well as the joint operating system in order to maximize the annual power generation produced by a power plant by using CSUDP, general-purpose dynamic programming (DP) software. The appropriate operating regulation curve forms (URC/LRC, MRC) were extracted from the DP results, and the annual power generations were simulated by inputting them as the basic operating data of the reservoir operation set of the HEC-ResSim program. By synthesizing the amount of the annual power generation simulated, the existing operation regulation curve, the operational performance, and the opinion of the field operator, the optimal reservoir operation regulation curves that maximize the annual power generation of the target power plant were developed. Results revealed that a system operating in conjunction with the reservoir produces about 2.5 % more power generation than an independent reservoir due to the synergistic effect of the connection.

A numerical study on the transient operation of high temperature heat pipe with a switching heat source (열원이 바뀌는 고온용 히트파이프의 천이 과정 동작에 관한 수치적 연구)

  • Park, Jong-Heung;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.68-78
    • /
    • 1997
  • A numerical study on the transient vapor flow and heat transfer is performed to investigate the ideal switching operation of heat source in a high temperature heat pipe. The cylindrical 2-dimensional compressible laminar vapor flow is assumed for the vapor space and the conjugate heat transfer for the heat pipe wall, wick and vapor space is calculated. The different boundary conditions such as constant heat flux, convective or radiative boundary at the outer wall are used respectively to compare the influence of boundary conditions on the transient operation. The transient temperature profile and the internal flow of the entire pipe for the switching operation are described as a result. The results show that the transient time is not significantly affected by the boundary conditions at the outer wall in present study. During the transition, two independent flows are observed temporarily on the right side and left side of the heat pipe. It is also found that the trend of temperature variation in the vapor region is different from the variation in the wick and wall region.