• 제목/요약/키워드: Independent Operation

검색결과 858건 처리시간 0.031초

클러스터 기반의 무선 분산 센서 네트워크에서의 터미널 간 신뢰도 평가 (Computing Reliability Cluster-based in Wireless Distributed Sensor Networks)

  • 이준혁;오영환
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제6권4호
    • /
    • pp.297-306
    • /
    • 2006
  • In this paper, We presented the algorithm for estimating a reliability between nodes in wireless distributed sensor networks (DSN). To estimate the reliability between nodes, we first modeled DSN as probability graph. Links of the graph are always reliable and the probability of node failure is independent. After all possible simple path which can be established between two nodes are examined, we perform sharp operation to remove repetition event between two nodes. Using probability for each variable of the minimized Boolean equation, we present the reliability formula.

  • PDF

Development and High Power RF Test of the Vacuum Feedthrough for KSTAR ICRF Antenna

  • Bae, Young-Dug;Hwang, Churl-Kew;Kwak, Jong-Gu
    • Nuclear Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.211-217
    • /
    • 2002
  • A 1-MW vacuum feedthrough for the KSTAR ICRF antenna is fabricated and high power RF test is performed. It is designed to have two alumina $(Al_2O_3)$ ceramic cylinders and O-ring seal instead of a brazed seal for good mechanical and thermal strength, which is important in long pulse or steady state operation. For cooling of the ceramics, dry air is circulated in a space between the two cylinders and the outer conductor. Independent cooling water channels are installed to cool the inner conductor of the feedthrough. RF high voltage test is performed using two kinds of ceramics with the purities of 99.7% and 97%. Stable operation is possible with the RF voltage of 30 kVp at long pulse of 300 sec without any severe damage.

Micro-Grids Reliability Enhancement Under Different Penetration Levels of Hybrid DG Units

  • Essam, M.;Atwa, Y.M.;El-Saadany, Ehab F.;Conti, Stefania;Rizzo, Santi Agatino
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1407-1418
    • /
    • 2018
  • Novel mechanism of customized adequacy formulation is proposed in order to enhance micro grids system reliability. The mechanism accounts for 2-levles of load curtailment, and is mainly based on probabilistic load profile and hybrid Distributed Generation (DG) units modeling. The two load curtailments are needed in order to ensure adequate technical constraints at steady state condition during islanding mode of operation. The effectiveness of the proposed formulation has been verified using system independent analytical expressions for the evaluation of both reliability and Expected Energy Not Served (EENS) indices. The evaluation has examined the impact of different penetration levels of Hybrid DG Units in case study islands. Results show the enhancement of the overall distribution system reliability and the recommended conditions for successful islanding mode of operation.

분산 독립형 변전소 종합 보호 제어 시스템 개발 (Development of Distributive Independent IDPACS(Integrated Digital Protection And Control System))

  • 고재학;조경래;안복찬;원희광;이권한;조남국;신희승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.919-921
    • /
    • 1996
  • Recently, a growing demands on electricity require a high performance and reliable operation in the area of protection, control and monitoring of power plants and substations which may not provides with conventional systems. This paper describes a novel IDPACS (Integrated Digital Protection And Control System) in which we integrate all protection, control and monitoring function of the substations. The simulation results show that the proposed system provides fast response and reliable operation of power plant with superb performance on protection and control system.

  • PDF

기술기준에 의한 거리계전기 정정시 고려사항 검토 (Considerations Review on Setting of Distance Relay using Technical Standards)

  • 문수철
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1141-1145
    • /
    • 2018
  • Generally, in nuclear plants, distance relay (21R) has adapting to protect and to operate main protective of transmission lines and backup protective of main generator. Operation of 21R was required and based on exactly accurate calculation and criteria. But presently method of 21R setting has applied according to protection devices operation guide of KPX, excepting IEEE and ISA standards, which have a difference review directions, consider parameters and devices, also consideration factors were affected to relay operations by uncertain guides. therefore this paper proposed new protection relay setting method and unvague criteria from IEEE 741 and ANSI/ISA 67.04.01, and reviewed a different results through numerical calculation results for methods and criteria including previous and established 21r setting by IEEE, ANSI/ISA Technical standards.

The Program Development for Real-Time Monitoring And Control of RF Output

  • Shin, Gang-wook;Hong, Sung-Tak;Yang, Jae-Rheen
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.69.6-69
    • /
    • 2001
  • The SSPA makes the power level of EIRP up to 16W, and compensates for temperature to the SSPA´s maximum stability. The up and the down converters are dually conversed like as individual synthesizers for selecting of independent transmit-receive transponder. The function of the up-converter is to convert the 70MHz IF signal modulated in the indoor unit modem into a 14.0 ∼ 14.5 GHz Ku-band up-link signal to be sent to the antenna. The down-converter converts the 12.25 ∼ 12.75 GHz Ku-band down-link signal or a trouble malfunction of SSPA may be a fatal factor to operation of the whole satellite communication network. Therefore, this study developed the remote monitoring and control program to monitor the SSPA´s status before the problem occurs for stable operation of the system. This software ...

  • PDF

Post Production in a Multi-format Environment

  • Pank, R. A.
    • 방송과미디어
    • /
    • 제4권4호
    • /
    • pp.46-51
    • /
    • 1999
  • The introduction of broadcast digital television (DTV) was, at one time, seen as an opportunity to rationalise video formats. The reality is quite different with a rapid divergence as the united States' ATSC offers 18 formats to cover both standard definition (SD) and high definition (HD), and yet more are supported by Europe's DVB. At the same time multi-media is expanding both as an area for source material and for finished work. Post production needs to move away from single-format facilities as requirements for multi-format operation is already increasing. A 'format-independent' solution is described which allows efficient operation with any mix of input formats and able to output any format with high quality. Attention is given to retaining the speed, accuracy and immediacy which is a feature of today's professional facilities -even while handling the greater demands of HD. Another route, using 24 frames-per-second is also examined.

  • PDF

AC 서보모터 제어 프로그램 구조 설계 및 구현 (Structure Design and Implementation of AC Servo Motor Control Program)

  • 김경아;최준영
    • 대한임베디드공학회논문지
    • /
    • 제18권5호
    • /
    • pp.209-215
    • /
    • 2023
  • This study proposes an AC servo motor control program structure and its implementation method to efficiently integrate 13 types of additional compensation algorithms into the basic FOC (field-oriented control) algorithm program. Various compensation algorithms are necessary to enhance the stability and performance of machine tools by compensating for interference from disturbances and vibrations. Each compensation algorithm is implemented as a separate, independent function and called from a switch-case statement in the ISR (interrupt service routine) of the PWM (pulse-width modulation) device. The advantages of this approach include facilitating not only debugging and testing but also reducing the possibility of errors during the program development phase. Thus, it is easy to add and activate each specific compensation algorithm for the program update during the program operation phase. The implemented motor control program was experimented with a single-axis feed shaft testbed driven by a commercial AC servo motor control drive board and a 750 Watts SPMSM (surface-mounted permanent magnet synchronous motor), and the results verified its normal operation and performance improvement.

Preoperative Neutrophil to Lymphocyte Ratio as a Prognostic Factor in Patients with Non-metastatic Renal Cell Carcinoma

  • Wen, Ru-Min;Zhang, Yi-Jing;Ma, Sha;Xu, Ying-Li;Chen, Yan-Su;Li, Hai-Long;Bai, Jin;Zheng, Jun-Nian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권9호
    • /
    • pp.3703-3708
    • /
    • 2015
  • Background: The neutrophil-to-lymphocyte ratio (NLR) is a strong predictor of mortality in patients with colorectal, lung, gastric cancer, pancreatic and metastatic renal cell carcinoma. We here evaluated whether preoperative NLR is an independent prognostic factor for non-metastatic renal cell carcinoma (RCC). Materials and Methods: Data from 327 patients who underwent curative or palliative nephrectomy were evaluated retrospectively. In preoperative blood routine examination, neutrophils and lymphocytes were obtained. The predictive value of NLR for non-metastatic RCC was analyzed. Results: The NLR of 327 patients was $2.72{\pm}2.25$. NLR <1.7 and NLR ${\geq}1.7$ were classified as low and high NLR groups, respectively. Chi-square test showed that the preoperative NLR was significantly correlated with the tumor size (P=0.025), but not with the histological subtype (P=0.095)and the pT stage (P=0.283). Overall survival (OS) and disease-free survival (DFS) were assessed using the Kaplan-Meier method. Effects of NLR on OS (P=0.007) and DFS (P=0.011) were significant. To evaluate the independent prognostic significance of NLR, multivariate COX regression models were applied and identified increased NLR as an independent prognostic factor for OS (P=0.015), and DFS (P=0.019). Conclusions: Regarding patient survival, an increased NLR represented an independent risk factor, which might reflect a higher risk for severe cardiovascular and other comorbidities. An elevated blood NLR may be a biomarker of poor OS and DFS in patients with non-metastatic RCC.

수협중앙회 이사회제도에 대한 수용자 태도 분석 (Analysis of Acceptors′ Attitudes toward the Board of Directors System of the National Federation of Fisheries Cooperatives(NFFC))

  • 정만화
    • 수산경영론집
    • /
    • 제35권2호
    • /
    • pp.1-29
    • /
    • 2004
  • This paper aims to understand the points which the Board of Directors of the National Federation of Fisheries Cooperatives System has proposed, and to find some improvement. This Fisheries Cooperatives previously had a single board system operating two small board rooms which became independent within the two sectors of credit and .provision in addition to the existing board of directors. This is a very unique board of directors system which is not found in cooperatives in our country nor in the business world. This change of the board of directors of the Fisheries Cooperatives is ascribed to the reorganization of the system into a completely independent division system, which operates business separately based on each sector as opposed to the previous multiple cooperatives system. However, a plural board of directors system does contribute to the improvement of managerial efficiency by strengthening the self-control of each independent business section, but deepens conflicts between its internal organizations, and brings about a reverse function which might deteriorate both the controlling power of a systematic organization and the coordinating power between sectors. This paper made an analysis of acceptors' attitudes toward the board of directors of the fisheries cooperatives system by regulating all the staff directly related to the operation of the board of directors of the fisheries cooperatives system as a group of acceptors and by selecting one hundred and fifty persons among the staff as a sample. The inquiry into acceptors' attitudes was made using questionaries, and the data for this investigation was processed and analyzed using a statistical method. The contents of this paper are composed of I. an introduction, II. the findings of the questionary investigation, III. the overall opinion for the improvement of the board of directors system, and IV. a summary and conclusion.

  • PDF