• 제목/요약/키워드: Increased airflow

검색결과 107건 처리시간 0.024초

흙먼지 분리기 용이한 원형베일 세절 조사료의 사이클론 이송장치 개발 (Development of Cyclone Conveying System for Transporting Chopped Round Bale Roughage and Separating Dust)

  • 하유신;권진경;박경규
    • Journal of Biosystems Engineering
    • /
    • 제36권3호
    • /
    • pp.204-210
    • /
    • 2011
  • This study developed the cyclone conveying system using roughage cutter for the round bale reported in the previous papers. Performance tests were conducted whether it can easily separate dust from roughage such as rice straws and it can transport roughages from cutter to TMR mixer. In addition, the airflow patterns in the cyclone conveying system were investigated using CFD code (FLUENT 6.2) for various velocities of dust collection fan. The cyclone conveying system was designed based on dried rice straws with a diameter of 1,340 mm, a cylinder length of 1,220 mm, a cone length of 850 mm and the current velocity of the dust collection fan was 15~20 m/s. It was found that transporting of roughage from cutter to TMR mixer and the separation of dust were satisfactory, and the dust removal rate of rice straws was around 31.9%. CFD analysis showed that, at the blowing fan velocity of 11.6 m/s, the airflow velocity inside the dust collector increased as velocity of the dust collection fan increased, but the airflow patterns inside the dust collector were all much the same.

만성기도폐쇄 환자에서 최대운동부하시 관찰되는 호흡양상 - 기도폐쇄정도와 흡기책임비율변화 사이의 상관관계 - (The Changes of Breathing Pattern Observed During Maximal Exercise Testing in the Patients with Chronic Airflow Obstruction : the Correlation Between the Change of Inspiratory Duty Cycle and the Degree of Airflow Obstruction)

  • 이계영;지영구;김건열
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권3호
    • /
    • pp.574-582
    • /
    • 1997
  • 연구배경 : 정상인에서는 운동부하시 증가되는 환기량의 요구를 초기에는 상시호흡량의 증가로 후기에는 호흡수의 증가로 충족시키며, 호흡수 증가에 따라 유발되는 호흡주기의 감소를 보상하기 위해 흡기책임비율이 50% 이상까지 증가하는 것으로 알려져 있다. 반면 만성기도폐쇄 환자에서는 환기능력의 감소와 생리적 사강 호흡의 증가로 인해 최대운동부하시 얕고 빠른 호흡양상을 보인다고 알려져 있지만 책임비율의 변화에 대해서는 연구가 많지 않고 이와 기도폐쇄정도와의 관련성에 대해서는 보고가 없는 실정이다. 방 법 : 12명의 만성기도폐쇄 환자와 10명의 정상인을 대조로 점진적 최대운동부하검사를 실시하였다. 결과 분석은 안정시에서 최대운동부하시점까지의 시간을 100%로 하여 rest, 20%, 40%, 60%, 80%, max 등% control duration으로 분획한 후 각 시점에서 1분 환기량, 상시호흡량, 호흡수, 생리적 사강비율, 흡기책임비율 등의 지표를 양군 간에 비교하였다. 결 과 : 1분환기량과 상시호흡량의 안정시에서 최대운동시까지의 변화는 양군 간에 유의한 차이가 관찰되었으나 호흡수는 유의한 차이를 나타내지 않았다. 생리적사강 비율은 정상대조군에 비해 만성기도폐쇄군에서 그 감소가 유의하게 낮았다. 흡기책임비율은 정상대조군에서 $38.4{\pm}3.0%$에서 $48.6{\pm}4.5%$로 증가한 반면 만성기도폐쇄군에서는 $40.5{\pm}2.2%$에서 $42.6{\pm}3.5%$로 별 변화가 없어 양군간에 유의한 변화의 차이가 있음을 확인할 수 있었고 이러한 흡기책임비율의 변화는 기도폐쇄정도 (FEV1%)와 유의한 상관관계가 있음을 확인할 수 있었다. (r=0.8151, p<0.05). 결 론 : 이상의 결과에서 만성기도폐쇄 환자는 최대운동부하시 정상에서 관찰되는 흡기책임비율의 증가가 발생하지 않으며 이는 기도폐쇄의 정도와 유의한 상관성을 갖고 있음을 확인할 수 있었다.

  • PDF

수압이 자흡식 마이크로버블 발생장치의 산소 용해율에 미치는 영향 (Effect of Hydraulic Pressure on Bubble Dissolution Rate of Ejector Type Microbubble Generator)

  • 김현식;임지영;박수영;김진한
    • 유기물자원화
    • /
    • 제25권2호
    • /
    • pp.27-31
    • /
    • 2017
  • 본 연구에서는 자흡식 마이크로버블 발생장치를 운전함에 있어서 수심 변화에 의한 수압이 산소 용해율에 미치는 영향에 대하여 평가하였다. 연구결과, 흡입 공기량의 경우 수압이 증가할수록 노즐 토출부에 작용하는 힘의 증가로 감소하는 경향을 나타내었다. 산소전달계수는 수심이 증가할수록 수압 증가에 의한 흡입 공기량 감소와 반응조 용적의 증가로 감소하는 경향을 나타내었으나 수심이 증가할수록 자흡식 마이크로버블 발생장치에서 발생되는 마이크로버블의 체류시간이 증가하여 산소 용해율은 증가하는 경향을 나타내었다. 그러나 자흡식 마이크로버블 발생장치 용량에 대비하여 수심이 과도하게 깊을 경우 낮은 흡입 공기량 및 산소전달계수로 인하여 산소 용해율은 감소할 것으로 판단된다. 따라서 자흡식 마이크로버블 발생장치 운전 시 수압이 중요한 고려사항이 됨을 확인할 수 있었다.

시물레이숀에 의한 상온통풍건조방법(常温通風乾燥方法)의 적정화(適正化)에 관(關)한 연구 -Part II : 최적퇴적(最適堆積)깊이와 최소건조비용(最少乾燥費用) (A Study of Natural Air Drying of Rough Rice Leading to Optimization -Part II - Optimum Grain Depth and Least Cost System-)

  • 정창주;고학균;노상하;한영조
    • Journal of Biosystems Engineering
    • /
    • 제7권1호
    • /
    • pp.42-52
    • /
    • 1982
  • This study was intended to develop a cost function for the natural air in-bin drying: system which could lead to an optimization of the drying system cost. Based on the cost function developed, a series of simulated drying tests were conducted with 10-year weather data (1970~1979) for 7 different regions by applying an appropriate levels of system factors. System performance factors treated in this study were initial moisture content, airflow rate, bin diameter and grain depth. An optimization procedure to find the least cost system was developed as follows: First, the worst year of the past decade was determined in consideration of the dryiang time and maximum dry matter loss. Second, the minimum airflow rate for a fixed bin diameter and grain depth was determined. Third, the optimum grain depth was found for the minimum airflow rate with different initial moisture contents and bin diameters. The results obtained in this study are summarized as follows: 1. The optimization procedure developed in this study was able to reduce the time and efforts significantly. 2. Optimum values of drying parameters including airflow rate, grain depth, and fan size were determined for different initial moisture contents and bin diameters in each region. The results are shown in Tables 3 to 9. 3. Optimum grain depths decreased as the initial moisture content and airflow rate increased. 4. Drying time for the least cost system should be reduced with higher initial moisture content and lower drying potential to prevent grain spoilage. 5. The fixed cost was 65 to 75 percent of the total system cost and the variable cost was 25 to 35 percent. To reduce the fixed cost it is desirable to use a drying bin 2 or 3 times a year.

  • PDF

Analysis of Airflow Pattern in Plant Factory with Different Inlet and Outlet Locations using Computational Fluid Dynamics

  • Lim, Tae-Gyu;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • 제39권4호
    • /
    • pp.310-317
    • /
    • 2014
  • Purpose: This study was conducted to analyze the air flow characteristics in a plant factory with different inlet and outlet locations using computational fluid dynamics (CFD). Methods: In this study, the flow was assumed to be a steady-state, incompressible, and three-dimensional turbulent flow. A realizable k-${\varepsilon}$ turbulent model was applied to show more reasonable results than the standard model. A CFD software was used to perform the numerical simulation. For validation of the simulation model, a prototype plant factory ($5,900mm{\times}2,800mm{\times}2,400mm$) was constructed with two inlets (${\Phi}250mm$) and one outlet ($710mm{\times}290mm$), located on the top side wall. For the simulation model, the average air current speed at the inlet was $5.11m{\cdot}s^{-1}$. Five cases were simulated to predict the airflow pattern in the plant factory with different inlet and outlet locations. Results: The root mean square error of measured and simulated air current speeds was 13%. The error was attributed to the assumptions applied to mathematical modelling and to the magnitude of the air current speed measured at the inlet. However, the measured and predicted airflow distributions of the plant factory exhibited similar patterns. When the inlets were located at the center of the side wall, the average air current speed in the plant factory was increased but the spatial uniformity was lowered. In contrast, if the inlets were located on the ceiling, the average air current speed was lowered but the uniformity was improved. Conclusions: Based on the results of this study, it was concluded that the airflow pattern in the plant factory with multilayer cultivation shelves was greatly affected by the locations of the inlet and the outlet.

Concentration variability of atmospheric radon and gaseous pollutants at background area of Korea between 2017 and 2018

  • Kim, Won-Hyung;Yang, Hyo-Sun;Bu, Jun-Oh;Kang, Chang-Hee;Song, Jung-Min;Chambers, S.
    • 분석과학
    • /
    • 제35권1호
    • /
    • pp.32-40
    • /
    • 2022
  • The concentrations of radon in the atmosphere were measured at the Gosan site of Jeju Island during 2017-2018, in order to investigate the time-series variation characteristics and the dependency of airflow transport pathways. The mean 222Rn concentration was 2,480 mBq m-3, and its monthly concentration in November was 3,262 mBq m-3, more than twice as that in July (1,459 mBq m-3). The diurnal radon concentrations increased throughout the nighttime to the maximum (2,862 mBq m-3) at around 7 a.m., then gradually decreased throughout the daytime by the minimum (1,997 mBq m-3) at around 3 p.m. The seasonal and monthly variations of CO, NO2, O3 showed a roughly similar pattern to that of radon for the same period, as high in winter and low in summer. The cluster back trajectory analysis described that about 60 % of overall airflow pathways was influenced by the airflow from China. The concentrations of radon and gaseous pollutants were relatively high as the airflow was influenced by China continent, but comparatively much lower as influenced by the northern Pacific Ocean.

광산 이직근로자의 만성폐쇄성폐질환 기류제한 중증도와 염증 및 산화스트레스 (Inflammation and Oxidative Stress as related to Airflow Limitation Severity in Retired Miners with Chronic Obstructive Pulmonary Disease)

  • 이종성;신재훈;백진이;정지영;최병순
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.251-258
    • /
    • 2019
  • Objective: Chronic obstructive pulmonary disease(COPD) is characterized by persistent airflow limitations associated with chronic inflammatory response due to noxious particles or gases in the lung. Inflammation and oxidative stress are associated with COPD. The aim of this study was to evaluate the relationship among inflammation, oxidative stress, and airflow limitation severity in retired miners with COPD. Methods: The levels of serum high-sensitivity C-reactive protein(hsCRP) as a biomarker for inflammation, degree of reactive oxygen metabolites(dROMs) and biological antioxidants potential(BAP) in plasma as biomarkers for oxidative stress were measured in 211 male subjects with COPD. Degree of airflow limitation severity as determined by spirometry was divided into three grades grouped according to the classification of the Global Initiatives for Obstructive Lung Disease(GOLD)(1, mild; 2, moderate; $3{\leq}$, severe or more) using a fixed ratio, post- bronchodilator $FEV_1/FVC$ < 0.7. Results: Mean levels of dROMs significantly increased in relation to airflow limitation severity(GOLD 1, 317.8 U.CARR vs. GOLD 2, 320.3 U.CARR vs. GOLD $3{\leq}$, 350.9 U.CARR, p=0.047) and dROMs levels were correlated with serum hsCRP levels(r=0.514, p<0.001). Mean levels of hsCRP were higher in current smokers(non-smoker, 1.47 mg/L vs. smoker, 2.34 mg/L, p=0.006), and tended to increase with degree of airflow limitation severity(p=0.071). Mean levels of BAP were lower in current smokers(non-smoker, $1873{\mu}mol/L$ vs. smoker, $1754{\mu}mol/L$, p=0.006). Conclusions: These results suggest that inflammation and oxidative stress are related to airflow limitation severity in retired miners with COPD, and there was a correlation between inflammation and oxidative stress.

Cellulolytic Enzymes Production Cultivation Using Air Circulation Bioreactor

  • Seo, Jin-Ho;Song, Hyo-Jung;Kim, Seong-Jun
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVII)
    • /
    • pp.232-237
    • /
    • 2005
  • The cellulloytic enzymes, such as FPase and amylase, production by Trichoderma inhamatum KSJ1 using 10L air circulation bioreactor were tried. Physical properties of the employed bioreactor, mixing time, $k_{L}$ a were examined in airflow conditions of enzyme production cultures. Mixing time of distilled water at 0.6, 1.2, 1.8 vvm were 25, 21, 9 sec, respectively, and mandel's medium using rice straw and pulp as carbon sources were 31, 25, 15 sec. Mixing time decreased when airflow rate increased. $k_L$ a of distilled water at 0.6, 1.2, 1.8 vvm were measured -22.52, -29.31, -39.62, respectively, and the mandel's medium were -47.8, -18.5, -21.4. The $k_L$ a values was increased linearly as the air-flow rates increased. However the values in mandel's medium showed different results, especially at 0.6 vvm. Amylase and FPase activity at the 1.2 vvm was 3.39U/mL, 0.72U/mL in 5 days cultivation. and the activities at 0.6 vvm were 2.01U/mL, 0.39U/mL, respectively. The enzyme productivity at 1.2 vvm was higher than at 0.6 vvm, indicating that high oxygen tension is requested for the efficient enzyme production culture of T. inhamatum KSJ1.

  • PDF

Solenoid 전동기의 냉각을 위한 수치해석적 연구 (Numerical Analysis of Heat Transfer Characteristics inside a Solenoid Motor System)

  • 정민채;윤상길;윤동진;서정세
    • 한국기계가공학회지
    • /
    • 제19권4호
    • /
    • pp.99-104
    • /
    • 2020
  • In this study, the temperature distribution and heat transfer characteristics of each component in a solenoid motor system were numerically investigated when heat is generated by the steel pad attached to the solenoid ring of the motor. It was found that the internal airflow was complicated by the inflow velocity of air and the rotation of guide rollers and solenoid rings. Based on the numerical results, the tendency for temperature changes in the steel panel was lower due to the contact of the cooling air in the front in the rotational direction, and the peak temperature was at the front of the center. In particular, it was confirmed that as the air inflow rate was increased, the temperature was reduced due to strong convection. The temperature of the iron plate pad was decreased as the convective heat transfer coefficient was linearly increased with increasing airflow around the solenoid ring. In addition, the temperature of the iron plate panel was rapidly increased with increasing heat generation.

기류제한 환자의 일산화탄소확산능 해석에서 폐용적 보정의 의의 (Importance of Carbon Monoxide Transfer Coefficient (KCO) Interpretation in Patients with Airflow Limitation)

  • 서용우;최원일;이정은;박훈표;고성민;원경숙;금동윤;이미영;전영준
    • Tuberculosis and Respiratory Diseases
    • /
    • 제59권4호
    • /
    • pp.374-379
    • /
    • 2005
  • 배 경 : 폐확산능 ($D_LCO$)과 폐용적을 보정한 확산계수($D_LCO/VA$; KCO)는 폐포용적이 비 정상적인 경우 차이가 생긴다. 그러나, 기류제한으로 비 정상적인 폐포용적을 가지는 환자에서 이러한 차이의 의미는 연구되지 않았다. 본 연구는 기류제한이 있는 환자에서 기류제한의 호전에 따른 폐확산능과 확산계수의 변화를 연구하고자 한다. 방 법 : 기류제한이 있는 환자에서 기저 폐기능과 더불어 폐확산능을 측정하고, 일회호흡 $CH_4$ 희석법으로 폐포용적을 측정하였다. 기저치에 따라서 환자는 다음의 두 군으로 나누었다. 확산계수(예측치에 대한 백분율)와 확산능(예측치에 대한 백분율)의 비가 115%를 넘는 경우를 고차이군으로 하였고, 115% 미만인 경우를 저차이군으로 하였다. 기류제한을 치료 한 후 폐기능검사와 폐확산능을 반복해서 측정하였다. 결 과 : 고차이군과 저차이군의 기저 폐기능은 유의한 차이가 관찰되지 않았다. 두 군 모두 확산계수의 예측치에 대한 백분율은 평균 113%와 100%로 정상범위였다. 치료 후 추적 폐기능에서 $FEV_1$과 FVC는 저차이군에 비해 고차이군에서 증가하였다. 고차이군에서 치료 후 측정한 폐기능은 기저치에 비해 폐확산능과 폐포용적은 증가하였으나 저차이군에서는 유의한 차이는 관찰되지 않았다. 전폐용적과 잔기량은 치료 전후에 양군 모두에서 유의한 차이가 관찰되지 않았다. 결 론 : 기류제한이 있는 환자에서 확산계수는 정상 범위에 있지만 확산능이 감소한 경우 확산능이 감소하지 않은 환자에 비해 가역적인 기류폐색이 클 것으로 예측할 수 있다.