• Title/Summary/Keyword: Inclusion-Degree

Search Result 136, Processing Time 0.023 seconds

Effects of Individual Fatty Acids on Receptor-Mediated Binding, Internalization and Degradation of $[^{125}I]LDL$

  • Choue, Ryo-Won;Cho, Byung-Hee Simon
    • BMB Reports
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 1997
  • The ability of Hep-G2 cells to process $[^{125}I]LDL$ under basal conditions was investigated. The receptor-binding and internalization of $[^{125}I]LDL$ increased with the time of incubation in a saturable manner. After 4 h of incubation, 31.4 ng of $[^{125}I]LDL$ was cell bound. The cells rapidly internalized $[^{125}I]LDL$ via specific, receptor-mediated endocytosis. The amount of internalized $[^{125}I]LDL$ reached a maximun of 96.7 ng at 2 h of incubation and remained constant for the next 2 h. The rate of degradation of internalized $[^{125}I]LDL$ proceeded in a linear manner over the entire 4 h of incubation after an initial lag period. The effects of individial fatty acids (C18:0. C18:1, C18:2. and C18:3), differing in their degree of unsaturation. on the receptor-binding, internalization and degradation of $[^{125}I]LDL$ were also investigated. Inclusion of 1.0 mM of each fatty acid into the culture medium significantly increased $[^{125}I]LDL$ metabolism in Hep-G2 cells. Among the fatty acids tested, stearic acid had the least effect on the receptor-binding activity. There were no significant differences among the unsaturated fatty acids in LDL-receptor binding. The effect of individual fatty acids on the $[^{125}I]LDL$ uptake was similar to that of the receptor-binding. showing a significantly lower effect with stearic acid. The amount of degraded material of internalized $[^{125}I]LDL$ was the lowest with stearic acid when it was compared with unsaturated fatty acids.

  • PDF

Development of the Expert System for Diagnosing Silicone Oil-filled Transformer (실리콘 유입변압기 진단을 위한 전문가시스템 개발)

  • 문종필;김재철;임태훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • In this paper, the diagnostic expert system for silicone oil-filled transformer is developed using dissolved gas analysis(DGA). There are many diagnostic methods for diagnostic oil-immersed transformer. But DGA is used to the proposed expert system since it has been verified that DGA is very efficient diagnostic method for transformer. In addition, it is resonable that fuzzy rule, degree of inclusion and fuzzy measure must be considered to handle the uncertainty nature of gas boundary and rules. The proposed expert system consists of knowledge base module, inference engine module and human-machine interface(HMI) module. The knowledge base module consists of the knowledge using the rule. The inference engine module is used to the fuzzy rule. The history of the transformer gas data is managed by the database. the effect of the proposed expert system is verified by case studies.

Preparation and characterization of PVDF/alkali-treated-PVDF blend membranes

  • Liu, Q.F.;Li, F.Z.;Guo, Y.Q.;Dong, Y.L.;Liu, J.Y.;Shao, H.B.;Fu, Z.M.
    • Membrane and Water Treatment
    • /
    • v.7 no.5
    • /
    • pp.417-431
    • /
    • 2016
  • Poly(vinylidene fluoride) (PVDF) powder was treated with aqueous sodium hydroxide to obtain partially defluorinated fluoropolymers with expected properties such as improving hydrophilicity and fouling resistance. Raman spectrum and FT-IR results confirmed the existence of conjugated carbon double bonds after alkaline treatment. As the concentration increased, the degree of defluorination increased. The morphology and structure of membranes were examined. The permeation performance was investigated. The results showed that membrane's hydrophilicity increased with increase of the percentage of alkaline treated PVDF powder. Moreover, in terms of the water contact angle, it decreased from $92^{\circ}$ to a minimum of $68^{\circ}$; while water up take increased from 128 to 138%. Fluxof pure water and the cleaning efficiency increased with the increase of alkaline treated PVDF powder. The fouling potential also decreased with the increase of the percentage of alkaline treated PVDF powder. The reason that makes blending PVDF show different characteristics because of partial defluorination, which led the formation of conjugated C = C bonds and the inclusion of oxygen functionalities. The polyene structure followed by hydroxide attack to yield hydroxyl and carbonyl groups. Therefore, the hydrophilicity of blending membrane was improved. The SEM and porosity measurements showed that no obvious variations of the pore dimensions and structures for blend membranes were observed. Mechanical tests suggest that the high content of the alkaline treated PVDF result in membranes with less tolerance of tensile stress and higher brittleness. TGA results exhibited that the blend of alkaline treated PVDF did not change membrane thermal stability.

A review on measuring cervical range of motion using an inertial measurement unit (관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰)

  • Yim, Juhyuk;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

A Study on Elementary School Teachers' Emotions in Science Teaching Avoidance (과학 교수를 기피하는 초등학교 교사의 감정 탐색)

  • Jang, Eunjin;Kim, Chan-Jong;Choe, Seung-Urn
    • Journal of Science Education
    • /
    • v.42 no.1
    • /
    • pp.80-93
    • /
    • 2018
  • This study tried to investigate whether it is appropriate to define the emotions of elementary school teachers, who avoid teaching science, as science teaching anxiety through exploring elementary school teachers' emotional expressions and related factors. 10 elementary school teachers who were reluctant to teach science participated in the research, and they presented their thoughts and feelings about teaching science through semi-structured interviews. As a result of analyzing the emotional expressions in the interview, 28 expressions of emotions appeared. Emotional expressions were divided into three types according to the degree of inclusion of factors related to anticipation in related situations. These results show that there are some emotional expressions that cannot be interpreted as the science teaching anxiety. Therefore, we propose to consider science teaching avoidance emotion not as science teaching anxiety but as a mixture of various emotions.

Improved Broiler Chick Performance by Dietary Supplementation of Organic Zinc Sources

  • Jahanian, Rahman;Moghaddam, Hasan Nassiri;Rezaei, Abbas
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.9
    • /
    • pp.1348-1354
    • /
    • 2008
  • Two inorganic (zinc sulfate and zinc oxide) and three organic (zinc acetate, zinc-methionine, and zinc-lysine) zinc sources were evaluated for their effects on the performance and carcass characteristics of broiler chicks. The birds were randomly assigned to one control (non-supplemented) and 15 treatment (supplemented) groups consisting of four replicates of 10 chicks each in a $5{\times}3$ factorial arrangement of treatments (five zinc sources and three supplemental zinc levels). Birds were kept in floor pens in a temperature-controlled room from 1 to 42 d of age and fed a non-supplemented basal diet (control) or the basal diet supplemented with 40, 80 or 120 mg/kg of Zn as mentioned sources. Dietary zinc source had considerable effect on feed intake in all experimental periods. Increasing Zn level from 80 to 120 mg/kg decreased the average feed intake in the growth stage (p<0.01) and also in the entire experimental period (p<0.001). Similarly, the average daily gain during the entire trial period was affected by the type of Zn source (p<0.001) and supplemental level (p<0.01). One degree of freedom contrast comparisons showed that the inclusion of organic zinc sources into the diets caused significant increases in feed intake and body gain when compared with inorganic counterparts. Except in wk 1, dietary supplementation with organic sources improved (p<0.05) feed conversion ratio; FCR values were not affected by dietary Zn source or supplementation level. Breast meat yield increased with supplemental levels of organic Zn sources; however, other carcass parameters were not affected by dietary Zn source. On the other hand, organic versus inorganic zinc supplementation caused a significant increase in liver, breast and carcass weight percentages. The present findings suggest that supplemental levels of organic Zn compounds had beneficial effects on broiler performance, and Zn requirements can be reduced using these feed supplements in poultry rations.

Ore Minerals and the Physicochemical Environments of the Inseong Gold-Silver Deposits, Republic of Korea (인성(仁成) 금(金)·은(銀) 광상(鑛床)에서 산출(産出)되는 광석광물(鑛石鑛物)과, 물리화학적(物理化學的) 생성환경(生成環境))

  • Lee, Hyun Koo;Moon, Hi-soo
    • Economic and Environmental Geology
    • /
    • v.22 no.3
    • /
    • pp.237-252
    • /
    • 1989
  • The Inseong gold-silver mine is located 3Km northwest of Suanbo, Choongcheongbugdo, Republic of Korea. The mine occurs in the shear zone formed by tension fractures within the Hwanggangri Formation of the Ogcheon metamorphic belt. Ore minerals found in the gold-silver bearing hydrothermal quartz vein composed mainly of pyrite, arsenopyrite, sphalerite, galena and minor amount of chalcopyrite, pyrrhotite, stannite, bismuthininte, native bismuth, chalcocite, electrum and tellurian canfieldite(?). The gangue minerals are quartz, calcite, chlorite and rhodochrocite. Wallrock alterations such as chloritization, silicitication, pyritization, carbonitization and sericitization can be observed in or around the quartz vein. According to the paragenetic sequence, quartz vein structure and mineral assemnlages, three different stages of ore formation can be recognized. The physico-chemical environment of ore formation in this deposit shows slight variation from stage to stage, but the condition of main ore deposition can be summarized as follows. Fluid inclusion, S-istope geothermometry and geothermometry based on mineral chemistry by use of arsenopyrite and chlorite show the ore was formed at temperature between 399 and $210^{\circ}C$ from fluids with salinities of 3.3-5.8 wt.% equivalent NaCl. It indicates that pressure during the mineralization is less than 0.6 Kb corresponding to a depth not greater than 1Km. S-isotope data suggests that thermal fluid may have magmatic origin wit some degree of mixing with meteoric water. In coclusion, the Inseong gold-silver deposit was formed at shallow depth and relatively high-temperature possibly with steep geothermal gradient under xenothermal condition.

  • PDF

The Effect of Using Massage Chair with Acupoint and Meridian Muscle Massage Program on Back Pain: A Single Arm Pre-post Comparison Study (경혈 및 경근 안마 프로그램이 적용된 안마의자 사용이 요통에 미치는 영향)

  • Choi, Su-Ji;Kim, Dong-Il
    • Korean Journal of Acupuncture
    • /
    • v.35 no.2
    • /
    • pp.82-90
    • /
    • 2018
  • Objectives : The purpose of this study is to investigate the effect of acupoint and meridian muscle massage given by automatic massage chair. Methods : We recruited 30 patients with back pain who met inclusion criteria. Two weeks were given as a waiting period, and the massage intervention was applied 12 times for 4 weeks. The programmed automatic massage chair was used to provide effective stimulus on acupoints and meridians for 20 minutes. We used Visual analog scale(VAS) and Korean Oswestry Disability Index(KODI) to quantify pain and function. We also recorded patients' all of vital signs and abnormal reactions during the trial to asses to assess safety. Results : Two participants dropped out due to personal reasons and 28 participants completed the clinical trial. We found that the degree of back pain (VAS, KODI) decreased significantly after the trial. As a result, VAS score decreased from $6.44{\pm}0.85$(Visit 2) to $4.59{\pm}1.52$ (Visit 14)(p<0.001), and KODI score was also reduced from $14.79{\pm}5.13$(Visit 14) to $9.04{\pm}4.52$ (Visit 2) (p<0.001). Also, we did not find any adverse effects in this study. Conclusions : We found that the acupoint and meridian muscle massage can effectively decrease back pain. This proves that the massage program designed by Korean medicine can be a good option to patients with back pain. However, further study with controlled design is still needed to verify its effectiveness.

Design and Implementation of Web Directory Engine Using Dynamic Category Hierarchy (동적분류에 의한 주제별 웹 검색엔진의 설계 및 구현)

  • Choi Bum-Ghi;Park Sun;Park Tae-Su;Song Jae-Won;Lee Ju-Hong
    • Journal of Internet Computing and Services
    • /
    • v.7 no.2
    • /
    • pp.71-80
    • /
    • 2006
  • In web search engines, there are two main methods: directory searching and keyword searching. Keyword searching shows high recall rate but tends to come up with too many search results to find which users want to see the pages. Directory searching has also a difficulty to find the pages that users want in case of selecting improper category without knowing the exact category, that is, it shows high precision rates but low recall rates. We designed and implemented a new web search engine to resolve the problems of directory search method. It regards a category as a fuzzy set which contains keywords and calculate the degree of inclusion between categories. The merit of this method is to enhance the recall rate of directory searching by expanding subcategories on the basis of similarity.

  • PDF

Estimating Stature and Weight from Anthropometry for the Elderly Who are Limited in Mobility (신체계측방법에 의한 거동이 제한된 노인들의 신장과 체중추정)

  • 한경희
    • Journal of Nutrition and Health
    • /
    • v.28 no.1
    • /
    • pp.71-83
    • /
    • 1995
  • The purpose of the study was to develop generalized equations for estimating stature and weight for the nonambulatory elderly persons. Height weight recumbent knee height total ann length, midarm, waist and calf circumferences, triceps and subscapular skinfolds were measured from over 60 years old 315 ambulatory elderly. The equations to predict stature and weight were derived from participants in the validation sample and were applied to the participants in the cross-validation to test the accuracy and validity of equations. Stature and weight were significantly and negatively associated with age of women and similar patterns observed in men but associated to a slight degree. Knee height and total arm length were highly correlated with stature but the majority of the variances in stature was accounted for by knee height for both the men and women. In men, waist circumference was the most significantly correlated with weight and am, calf circumferences and so forth. But in women arm circumference was the highest then waist and calf circumference in order. The possible predictor variables to estimate of stature were knee height total arm length and age for both elderly men and women. Predictor variables to estimate of weight were recumbent measures of waist am, calf circumferences and knee height for both sexes. Inclusion of skinfold thickness measurements did not improve the prediction power of estimation for weight. When both equations developed from the present study and Chumlea's study were applied to cross-valida-tions samples, the equations derived from present study showed better accuracy and validity. The presentation of prediction equations using two, three, or four recommended measurements allows the selection of an equation based upon the measurements that are possible to collect on an individual basis.

  • PDF