• Title/Summary/Keyword: Incineration facility

Search Result 67, Processing Time 0.02 seconds

악취물질인 유기산 제거를 위한 DBD 플라즈마 촉매 복합공정의 적용 (Application of DBD Plasma Catalysis Hybrid Process to remove Organic Acids in Odors)

  • 홍은기;서정민;최금찬
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1627-1634
    • /
    • 2014
  • Odor control technology include absorption, adsorption, incineration and biological treatments. But, most of processes have some problems such as secondary organic acids discharge at the final odor treatment facility. In order to solve the problems for effective treatment of organic acids in odor, it is necessary to develop a new type advanced odor control technology. Some of the technology are plasma only process and plasma hybrid process as key process of the advanced technology. In this study, odor removal performance was compared DBD(Dielectric Barrier Discharge)plasma process with PCHP(plasma catalysis hybrid process) by gaseous ammonia, formaldehyde and acetic acid. Plasma only process by acetic acid obtained higher treatment efficiency above 90%, and PCHP reached its efficiency up to 96%. Acetic acid is relatively easy pollutant to control its concentration other than sulfur and nitrogen odor compounds, because it has tendency to react with water quickly. To test of the performance of DBD plasma process by applied voltage, the tests were conducted to find the dependence of experimental conditions of the applied voltage at 13 kV and 15 kV separately. With an applied voltage at 15 kV, the treatment efficiency was achieved to more higher than 13 kV from 83% to 99% on ammonia, formaldehyde and acetic acid. It seems to the odor treatment efficiency depends on the applied voltage, temperature, humidity and chemical bonding of odors.

폐기물소각로의 고온 연소에 따른 문제와 연소실 전열면 변경에 대한 연구 (A Study on the Facility for Domestic Waste Problems of high Temperatured Combustion and the Alteration of heating surface)

  • 김성중
    • 유기물자원화
    • /
    • 제18권3호
    • /
    • pp.60-67
    • /
    • 2010
  • 우리나라의 대형 생활폐기물소각시설의 건설시기를 보면 상당수가 1980년대 후반인 것을 알 수 있다. 대부분의 시설들은 이 시기에 설계되었으며 그 후에 건설된 소각로 역시 변경이나 조정 없이 시설해온 것으로 조사되고 있다. 그러나 소각로에 반입되는 폐기물의 성상은 정부의 폐기물수거 정책에 의해 급격히 변화하고 있다. 이는 생활폐기물의 발열량변화를 조사해 봄으로도 쉽게 알 수 있다. 그 결과 많은 소각시설에서 과열에 의해 내화물과 화격자가 손상되고 있다. 한편 보일러 전열면에 클링커가 생성되어 열전달에 방해를 줌으로 이용열량이 줄어들 뿐만 아니라 연소실의 온도가 상승되는 등 원하지 않는 현상이 연속되고 있다. 이를 개선하기 위해 폐기물저장고에 물을 뿌리거나, 분리수거해 온 음식물류 폐기물을 다시금 혼합하여 혼소하거나 연소실에 물을 분사하는 방법을 동원하고 있다. 이러한 방법은 근본적인 해결책이 되지 않으며, 설계부터 다시 하여 새로 시설하는 것 또한 비용적인 측면에서 효과적이지 못하다. 따라서 본 연구를 통해 위와 같은 문제를 원천적으로 해결 하기위한 방법을 도출해 보았다.

환경기초시설 운영을 위한 ISO14001 기반 u-LCA 시스템 개발 (ISO14001-based u-LCA System Development for Operation of Environmental Facilities)

  • 한광록;이기철;손석원
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.2117-2125
    • /
    • 2009
  • 본 논문은 환경오염방지 및 처리에 관한 설비 등 환경기초시설에서 운영 적정성에 대한 정보화 시스템 즉, 환경기초시설 통합관리 시스템 개발에 관한 것이다. 이것을 개발하여 오염 원인물질의 생성부터 오염방지처리, 소멸에 이르기까지 전 과정(Life Cycle)에 대한 환경성 개선과 효과의 극대화를 이룬다. 이를 위해서 환경에너지시설의 환경경영 국제표준인 ISO14001 기반의 소각시설 정보화 시스템인 환경기초시설의 운영을 위한 유비쿼터스 전과정 평가시스템(u-LCA: Ubiquitous Life Cycle Assessment)을 개발하였다. 개발된 시스템은 현재 고양시 소각장에 적용하여 시범 운영 중이다. 이로 인하여 관리자들은 실시간으로 소각로의 운영 실태를 확인하고 문제점들을 즉시 개선할 수 있다.

배출량 분포에 따른 대구시 일산화탄소 측정망 위치의 적절성 평가 (Assessment of the Locations for Carbon Monoxide Monitoring Stations in Daegu according to Emission Distribution)

  • 김효정;조완근
    • Spatial Information Research
    • /
    • 제20권2호
    • /
    • pp.25-34
    • /
    • 2012
  • 대구지역은 주위가 산으로 둘러싸인 분지형 도시이기 때문에 대기 환경 쾌적성이 타 도시 보다 낮은 편이다. 따라서 본 연구에서는 대구지역 자동대기오염측정소의 위치를 일산화탄소(CO) 배출량 분포에 기초하여 CO를 체계적으로 관리하기위한 적합한 장소에 대해 조사하였다. 이를 위하여 현재 대구지역 CO 관리정책 수립에 기초자료를 제공하는 자동대기측정소의 위치 적절성에 대하여 평가하였다. 대구시 수치지도와 환경부에서 제공하는 CAPSS(대기정책지원시스템 ; Clean Air Policy Support System) 자료를 활용하여 배출량 지도를 작성하였다. 도로, 아파트, 공장, 소각장 4가지로 구분하여 배출량을 입력한 뒤 법정동별 평균 배출량을 산출하였다. CO 배출지역을 고 배출량 지역과 저 배출량 지역 10단계로 구분하고 현재 측정소가 어느 단계에 해당하는지 조사하였다. 결과적으로, 저 배출량 지역 보다는 CO 고 배출량 지역에 해당하는 측정소가 부족한 것으로 나타났다. 특히, 1999년부터 2007년까지 공통적으로 추가 설치가 필요하다고 나온 국우동 외 6곳에 CO 측정망이 설치된다면 보다 다양한 기초 자료의 제공으로 체계적인 CO 관리가 가능할 것으로 판단된다.

함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구 (A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air)

  • 신미수;신나라;장동순
    • 대한환경공학회지
    • /
    • 제35권2호
    • /
    • pp.115-123
    • /
    • 2013
  • 도시폐기물 소각로는 일반적으로 전처리 설비가 필요 없고 대용량에 적합한 스토커타입의 소각로를 많이 사용하고 있다. 그러나 음식물 쓰레기의 직매립 금지 등에 따라 반입폐기물의 가연분이 증가하고 수분함량이 감소되어 폐기물의 발열량이 소각로 설치 초기에 비해 매우 증가하고 있는 실정이다. 이에 소각로 열부하의 증가에 따라 소각량 감소와 가동률 저하 등 소각로 운영에 어려움을 겪고 있다. 본 연구는 D시의 소각로를 대상으로 하여 소각량과 함습공기 양등 중요 변수에 따른 NO 모델을 포함한 난류반응 유동에 대한 일련의 전산해석을 수행하여 기초 자료를 축적하고 그것을 바탕으로 최근 도시 폐기물의 고 발열량화에 따른 문제점 및 해결방안에 대한 연구를 수행하였다. 이에 따라 운전조건 등을 최적화하여 기존의 운전시설의 활용을 극대화 하고자 하였다. 폐기물의 소각량을 저감하지 않고 고발열량화의 문제를 해결할 수 있는 실질적인 방법으로 연소용 공기에 수분의 양을 10%와 20%로 증가시키며 가습공기를 주입하는 방안을 검토하였다. 그 결과 연소공기의 비열증가와 상변화 등에 의하여 최대 화염온도의 감소가 발생하여 전반적인 소각로 내부의 온도가 낮아지는 것으로 나타났으며 그에 따라 NOx 발생량이 실질적으로 감소되는 것으로 나타났다. 특히 가습공기 20%주입시 기존에 설치되어 있는 SNCR 설비의 환원제 주입구 위치가 대부분 SNCR 반응에 적합한 온도 영역으로 나타나서 현재 고발열량 문제로 전혀 가동하지 못하고 있는 SNCR 설비의 재가동을 고려해 볼 수 있을 것으로 판단된다.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

제철소 적용을 위한 저온형 금속지지체 탈질 코팅촉매 최적화 연구 (An Optimization Study on a Low-temperature De-NOx Catalyst Coated on Metallic Monolith for Steel Plant Applications)

  • 이철호;최재형;김명수;서병한;강철희;임동하
    • 청정기술
    • /
    • 제27권4호
    • /
    • pp.332-340
    • /
    • 2021
  • 최근 사업장 질소산화물(NOx) 배출허용기준 강화(2019년 1월 적용)에 따라 다량 배출사업장에서 배출되는 질소산화물을 배출허용기준 이하로 만족하기 위한 노력이 필요하다. 대표적인 질소산화물 저감 방법으로 선택적 촉매 환원법(selective catalytic reduction, SCR)을 주로 사용하고 있으며, 일반적으로 세라믹 허니컴(ceramic honeycomb) 촉매를 사용하고 있다. 본 연구에서는 높은 열적 안정성과 기계적 강도를 가지는 금속지지체 탈질 코팅촉매를 적용하여 제철소에서 배출되는 질소산화물를 저감하기 위한 연구를 수행하였다. 금속지지체 코팅촉매는 최적화된 촉매슬러리(catalyst slurry) 코팅방법을 통해 제조하였고, 내마모 시험과 굽힙 시험을 통해 코팅된 촉매가 균일하고 강건하게 부착되어 있음을 확인하였다. 금속지지체가 가지는 우수한 열전도 특성으로 인해 저온영역(200 ~ 250 ℃)에서 세라믹 허니컴 촉매보다도 우수한 탈질효율을 보였다. 또한 경제적인 촉매 설계를 위해 금속지지체 표면 상에 코팅되는 촉매의 최적 코팅량을 확인하였다. 이러한 연구결과를 바탕으로 제철소 배기가스 모사환경에서 상용급 금속지지체 코팅촉매에 대한 준파일럿 탈질 성능평가를 수행하였고, 저온영역(220 ℃)에서도 배출허용기준치(60 ppm 이하)을 만족하는 우수한 성능을 나타내었다. 따라서 물리화학적 특성이 우수한 금속지지체 코팅촉매가 최소량의 촉매 사용으로도 우수한 탈질 성능을 나타내었으며, 넓은 비표면적을 가지는 고밀도 금속지지체 적용을 통해 배연 탈질 촉매 반응기의 콤팩트화 및 소형화가 가능하였다. 이러한 결과를 바탕으로, 본 연구에서 사용된 금속지지체 코팅촉매는 제철소뿐만 아니라 화력발전, 소각장, 선박, 건설기계 등 다양한 산업 분야에 적용할 수 있는 새로운 형태의 촉매가 될 것이다.