• Title/Summary/Keyword: Incineration facility

Search Result 67, Processing Time 0.024 seconds

Certification and Quality Control of the Official Test Facilities of Dioxins in Korea (국내 다이옥신 측정분석기관 지정 및 정도관리)

  • Jang, Seong-Ki;Kim, Tae-Seung;Lee, Won-Seok;Chung, Young-Hee;Choi, Doug-Il
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.675-682
    • /
    • 2000
  • The concentration of dioxins from flue gases of municipal waste incineration facilities with capacities over 50 tons/day are regulated by the guideline: $0.1ng-TEQ/Nm^3$ for new facilities, and $0.5ng-TEQ/Nm^3$ for existing facilities and it will be strengthened to $0.1ng-TEQ/Nm^3$ until 2003 year. Dioxins from these incineration facilities have to be measured more than 2 times annually by the Official Test Facilities of Dioxins. Seven institutions have been certified so far as the Official Test Facilities of Dioxins. These facilities have to be evaluated by the quality control program provided by National Institute of Environmental Research every year. We reported the results of quality control test performed in 1999. Four institutions certified in 1998 sampled flue gases at stack of M incineration facilitiy and analyzed dioxins by Official Methods of Air Pollution. The isokinetic coefficients, the parameter for evaluation of sampling ability were excellent for all four institutions. They were 100.9%, 102.4%, 102.1% and 99.2%, respectively. The criteria required are as follows; resolution over 10,000, mass calibration within ${\pm}5ppm$, ion abundance ratio within 15%, and the recovery of 50-120%. As results, those institutions also met these parameters of Official Method of Air Pollution.

  • PDF

Understanding and Improvement of Best Available Techniques for Waste Incineration Facility (폐기물 소각시설 최적가용기법 (BAT) 기준서의 이해와 개선방향)

  • Shin, Sujeong;Park, Jae-Hong;Park, Sang-Ah;Lee, DaeGyun;Kim, Dai-Gon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.533-543
    • /
    • 2017
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In order to facilitate the implementation of integrated environmental pollution prevention act with these advantages, the BAT BREF should be published, modified and revised every 5 years considering the level of scientific development. This study reviewed the issues to be considered in applying BAT and the types of BAT and focused on presenting improvements and development direction when revising and supplementing the standards in the future based on these contents. For this purpose, when revising the standards, it will be necessary to reflect on the domestic situation, to expand the TWG(Technical Working Group) of small-scale workplace experts, and to exchange opinions with business places that have similar processes for each waste type through a systematic total inspection. In addition to these methods, by establishing a resident participation system through information disclosure, it is expected to be used as a guideline for environmental management of business places not subject to integrated permission of less than 3 types as well as those subject to integrated permission.

Characteristic of Electric Generation for the Water Flow Rate in Thermoelctric Generator Using Hot Water (온수를 이용한 열전발전기에서 유량변화에 따른 발전 특성)

  • Woo, Byung-Chul;Lee, Hee-Woong;Suh, Chang-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1333-1340
    • /
    • 2002
  • The objective of this study is to develop a thermoelectric generation system which converts unused energy from close-at-hand sources such as garbage incineration heat and industrial exhaust etc. into electricity. This paper presents applicability of a commercially available thermoelectric generator f3r waster heat recovery. The test facility consists of water heater, pump, thermoelectric module and aluminium tubes and hot and cold water is used as heat source and sink fluids. It is shown that the three components of thermoelectric research exist in manufacturing a thermoelectric generator. The first component is fabrication of thermoelectric materials, the second is manufacturing of thermoelectric generator with 32 thermoelectric modules. The last one is characteristic measuring of thermoelectric generator with 32 thermoelectric modules of two types, cooling and power purpose. It was found that the rate of cold and hot water is 25 and 37 liter per minute and the maximum power of thermoelectric generator is 28Watts and its efficiency is 1.04%.

Analysis and estimation of the BTEX using Canister­GC/MS in Seongseo Industrial Complex (Canister와 GC/MS를 이용한 대구성서산업단지의 BTEX의 분석 및 평가)

  • Kim Tae-Sub;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.3
    • /
    • pp.351-358
    • /
    • 2005
  • The research in this paper was carried out to examine the BTEX(Benzene, Toluene, Ethylbenzene, Xylene) concentrations in Seongseo Industrial Complex. These compounds are the major constituents, more than $60\%$ in composition of total VOCs, mainly charging in ambient air. BTEX samples were collected from the 38 sites, 10 for the source points and 18 for the boundary sites, and were analyzed by canister-GC/MS. The mean concentrations of BTEX were 33 ppbv for benzene, 214 ppbv for toluene, 89 ppbv for ethyl benzene, 77 ppbv for xylene. Among the BTEX, toluene had the highest concentration in the source points and boundary sites. In the source points, BTEX concentration of incineration facility for hazardous wastewater appeared highly in the range of 220­350 ppbv. BTEX concentrations in source boundary sites appeared in the order of toluene>ethylbenzene>xylene>benzene. As a result of the correlation analysis, the concentration of the source points was related to those of the boundary sites. Correlation of ethylbenzene and xylene was presented to 0.7991(P<0.0 1),\;0.6329(P<0.05) as the correlation coefficient, respectively.

A numerical study on design parameters of pyrolysis-melting incinerator (열분해 용융 소각로 설계인자 도출을 위한 수치해석적 연구)

  • Shin, Dong-Hoon;Jeon, Byung-Il;Lee, Jin-Ho;Hwang, Jung-Ho;Ryu, Tae-Oo;Park, Dae-Gyu
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.243-250
    • /
    • 2003
  • The present study discuss about numerical methods to analyze design parameters of pyrolysis-melting incineration system. Various numerical methods of different viewpoint are introduced to simulate the performance of the system. Process analysis of the overall system is the beginning procedure of basic design process. Heat and material flow of each element are connected and are influential to each other, hence, an appropriate process modeling should be executed to prevent from unacceptable process design concepts that may results in system failure. Models to simulate performance of each elementary facility generate valuable informations on design and operation parameters, and, derive the basic design concept to be optimized. A pyrolysis model derived from waste bed combustion model is introduced to simulate the mass conversion and heat transfer in the pyrolysis process. CFD(Computational fluid dynamics) is an effective method to optimize the thermal reacting flow in various reactors such as combustor and heat exchanger. Secondary air jets arrangement and the shape of the combustor could be optimized by CFD technology.

  • PDF

A Study of the Sectionalizing for Pipe Deterioration Evaluation in Industrial Facilities (산업시설 배관 노후도 평가를 위한 배관 섹션화 방안 연구)

  • Min, Hyuk-Ki;Kim, Sang-Bum;Kim, Byung-Woo;Kim, Hyoung-Ki;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • In general, no particularly well-established standards have been in place so far, for the method of evaluating the deteriorated level of pipes and ducts of industrial facilities. For that reason, the evaluation depends upon various studies which are based on the analysis of the residual life, thickness thinning, closure rate, and scale thickness that measure a few specific positions of pipes. It also depends upon the expertise in business operation and the specific techniques conducted by the inspection companies and institutions. This research introduces the concept of measuring units per section and the selection method of measurement points per section. Furthermore, specific methodologies were developed to plan and analyze deterioration level of industrial pipes and ducts by engineers and managers using a section map. Consequently, applying the outcomes from this study to the plant equipment of the incineration facility resulted in saving 42% of the repairing and remodeling cost.

Investigation on Economical Feasibility for Energy Business of Waste Water Sludge Discharged in 'A' Industrial Complex (A-산업단지 발생 슬러지의 에너지화를 위한 경제성 검토)

  • Byun, Jung-Joo;Lee, Kang-Soo;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.61-74
    • /
    • 2012
  • Industrial complexes in Korea have been vigorously established by economic development plan and development policy of industry in 1960s. Recently, Korean government has promoted Eco Industrial Park (EIP) project to recycle by-products and wastes in industrial park In this study, we analyzed the physical and chemical properties for the sludges discharged from A industrial complex. And we investigated the economic feasibility and environmental impact of sludge to energy facilities. The analysis results indicated that the petrochemical industry were 92% in sludge production, the highest treatment amount was landfill, followed by incineration and recycling and then ocean disposal. Wastewater sludge and process sludge samples are collected and analyzed to use as basic data on economic feasibility and environmental impact. Weighted average heating value of sludge samples was 3,891kcal/kg. Based on this data, installation and operation costs, operation returns of operating the drying facility are estimated, compared with cogeneration facility. And this study examines how the payback period of each simulation(total 8 case) with the important parameter changes. As a result, it was found that what needs the shortest payback period is 3years with connection of drying facility and cogeneration facility based on the government's financial subsidy system.

A Study on Environmental Impact Assessment Guidelines for Marine Environmentsin Construction Projects of Offshore Waste Disposal Landfills (해상최종처리장 건설사업의 해양환경 환경영향평가 가이드라인 개발 연구)

  • Lee, Haemi;Son, Minho;Kang, Taesoon;Maeng, Junho
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.312-331
    • /
    • 2019
  • An offshore waste disposal facility refers to a landfill site for final landfilling of stabilized inorganic solid waste such as land and marine waste incineration materials, and the aim of such a facility is to solve the problem of insufficient waste disposal space on land and create and develop environmentally friendly marine spaces. The purpose of this study is to prepare guidelines for the construction of offshore waste disposal facilities, which reflect the need and importance of paying sufficient heed to environmental considerations from the initial stage of the project, in order to investigate, predict, and assess how such guidelines will affect the marine environment in relation to the construction of offshore waste disposal facilities, with the goal of minimizing the impact on and damage to the environment. For the purpose of this research, guidelines focusing on the construction of offshore waste disposal facilities were derived through an analysis of domestic cases and similar foreign cases and an assessment of their level of compliance with existing EIA guidelines through the operation of a discussion forum. In order to review the EIA report on similar cases in Korea, 17 EIA documents (2005~2016) for dredged soil dumping areas and ash ponds of thermal power plants were analyzed to investigate the status of marine organisms, marine physics, marine water quality, and marine sediment and to understand what types of problems can occur and what improvement measures can be taken. The purpose of these guidelines were to minimize damage to the marine environment by promoting EIA protocols in accordance with scientific and systematic procedures, to reduce the consultation period related to projects, to resolve social conflicts, and to reduce economic costs.

Farm Animal Mortality Management Practices in Sunchon-si (순천시의 폐사가축 처리실태에 관한 연구)

  • Hong, Ji-Hyung
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • Disposal methods of managing carcass in Korea livestock production systems include burying, digesting, rendering, carcass dumping to manure pile, dead animal disposer and mini-incinerator. Burying was usually the most practical method of carcass disposal in our livestock farms. Burying, carcass dumping to manure pile, dead animal disposer and mini-incinerator may have environmental regulatory and economic liabilities when used as a means of carcass disposal. In many cases in this survey, these disposal methods offer a poor choice for the producer due to individual site conditions, geology, cost, air emissions, rendering plants. A survey questionnaire that addressed the issues to livestock producers was prepared. The questionnaire addressed two main topics as follows: 1) types of livestock and generation amounts of carcass 2) Number of breeding animals and disposal methods of livestock mortality. A total of 36 livestock producers were interviewed. The results of obtained in this survey were summarized as follows: The number of breeding poultry, swine, beef cow and dairy cow was 251,000, 2,600, 142 and 92 heads per year and the generation amounts of annually carcass was 0.46, 15.32, 0.36, 1.36 tons per year of each poultry, swine, beef cow and dairy cow farms, respectively. The disposal methods of carcass were burying (42%), carcass dumping to manure pile (36%), rendering (8%), incineration (6%), digesting (6%), carcass disposer (2%), respectively. These results can be used as basic information to establish the standard of carcass composting facility.

Comparison of the CO2 Emissions Estimations among Four Tier Methods for the Facilities from Different Industrial Sectors in Korea (국내 산업 부문에 대한 온실가스 배출량 산정 방법 결과 비교)

  • Kim, Hee Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.195-209
    • /
    • 2012
  • There are four differentiated levels to quantify the amount of greenhouse gas emissions from a facility, which are Tier 1 to 4 based on the IPCC guidelines. In this study, the emission estimates from all tier levels were calculated to compare their total $CO_2$ emission results among themselves for seven facilities, including three sectors of electricity generation, municipal solid waste incineration, and cement manufacturing for three months between February and May 2011. Generally the measured $CO_2$ emissions by Tier 4 were higher than the calculated $CO_2$ emissions by Tier 3, which had been also observed for the power plants in the USA. It was found out that to obtain more reliable estimation for Tier 3, accurate analysis of the composition of the fuel used should be carried out. It was suggested that further refinement on the administrative guidelines be made to make it more robust.