• 제목/요약/키워드: Inception voltage

검색결과 104건 처리시간 0.03초

Evaluation of Winding Insulation of IGBT PWM Inverter-Fed Low-Voltage Induction Motors

  • Park Doh-Young;Hwang Don-Ha;Kim Yong-Joo;Kang Do-Hyun;Lee Young-Hoon;Kim Dong-Hee;Lee In-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.470-474
    • /
    • 2001
  • IGBT inverters have switching rise times of 0.2-2 $\mu$ sec, and have been believed to cause insulation stresses and premature motor failures. Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted many concerns due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 19 low-voltage induction motors are presented. Different types of insulation techniques are applied to 19 motors. The insulation characteristics are analyzed with partial discharge, discharge inception voltage, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed, and the corresponding breakdown voltages are obtained.

  • PDF

침 전극 기울기에 따른 초고압 절연체 XLPE의 부분방전 패턴해석 (Analysis of Partial Discharge Pattern according to Needle Electrode Slope in XLPE for Ultra High Voltage insulators)

  • 안병철;김탁용;이강원;이덕진;신종렬;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.162-163
    • /
    • 2006
  • XLPE is used to insulator for Ultra High Voltage power cable. It is easy to processing also has a good insulating property. The study for diagnosis of lifetime and improvement is proceeding continuously. In this paper, it is investigated partial discharge distribution according to slope of needle electrode 0, 20, $40^{\circ}$. Applied voltage is 0.5 [kV/s] by step form for inception voltage. As the result of study, we conformed that increase of slope led to reduce of discharge number and total discharge quantity.

  • PDF

고압 회전기 On-line 부분방전 측정용 Ceramic Coupler 특성 (Characteristics of Ceramic Coupler for On-line Partial Discharge Measurement in High Voltage Rotating Machines)

  • 강동식;윤대희;김용주;이홍식;윤영호;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.204-212
    • /
    • 2002
  • In order to improve the reliability of high voltage rotating machines, it is necessary to understand the breakdown mechanism of stator windings. Especially partial discharge(PD) inception and growth are important in stator winding insulation. Recently, many research on the diagnosis of stator winding insulation for large rotating machines have been developed since the 1970s. Capacitive couplers have been the most widely used sensor for on-line partial discharge detection in rotating machines. This paper deals with the electrical on-line monitor characteristics of ceramic coupler(CC) which has been developed to continuously measure the PD activity in operating high voltage motor stator windings on site. We investigated the electrical characteristics(PD quantity, breakdown voltage and frequency response) to develop CC. This paper presents frequency characteristics and laboratory test result to compare conventional 80([F] epoxy-mica coupler(EMC) and 105[pF] CC for PD measurement with 6.6㎸ model stator windings.

3상 농형 유도전동기 회전자 바의 고장진단에 관한 연구 (A Study on The Diagnosis of Broken Rotor Bars in Three Phase Squirrel-Case Induction Motor)

  • 김근웅;권중록;이갑재;김완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.635-637
    • /
    • 2001
  • The faults of the squirrel cage induction motor is grew increasingly complex as the faults resulting in the shorting of a stator winding and the broken rotor bar or cracked rotor end ring, bearing faults, and so on. The users of electrical machines initially relied on simple protections such as over-current, over-voltage, earth-fault, etc. to ensure safe and reliable operation. but this method cause heavy financial losses and the threat of safety therefore it has now become very important to diagnose faults at there very inception. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA) and the opening terminal voltage signal analysis.

  • PDF

금속증착 폴리프로필렌 필름의 마진에 따른 기중 연면방전 특성 (The Flashover Characteristics by the Margins on Metalized Polypropylene Films in Air)

  • 류성식;김영찬;정용기;정종욱;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2386-2388
    • /
    • 1999
  • This paper describes the surface discharge characteristics which can be used as data to determine the optimumal length in margin which plays an important role in improving the energy density and the life-time of high voltage capacitors. In this experiment, the margin of metalized polypropylene films(MPPFs) is varied in length in order to measure and analyze flashover voltages and partial discharge inception voltages (PDIVS). As a result, the flashover voltage and the PDIV are increased with margin and tracking was observed.

  • PDF

전기수력학적 미립화에서 액적 형성에 영향을 미치는 인자에 관한 실험적 연구 (A Study on Influence Factors on Drop Formation in Electrohydrodynamic Atomization)

  • 성기안;이창식
    • 한국분무공학회지
    • /
    • 제8권2호
    • /
    • pp.24-30
    • /
    • 2003
  • An experimental study was performed to investigate the influence factors of drop formation in electrohydrodynamic atomization. The mode of electrohydrodynamic atomization depended on the various factors such as the flow rate of the liquid, the inner diameter of the nozzle, the distance between the nozzle tip and the ground electrode, the shape of the ground electrode. and the applied high voltage. This work was performed to investigate the experimental analysis for the flow pattern visualization of droplets, and the relationship between voltage application and the behavior of liquid atomization. Uniform drops of different sizes can be obtained at the inception of the spindle mode by charging the flow rate and the electric field. The drop size also decreased when the flow rate was raised for the spindle mode. The whipping motion occurred beyond 7kV and before the corona started to take effect.

  • PDF

고분자 절연재료내의 Tree성장과 유전손 특성에 미치는 초음파의 영향 (The Effect of Ultrasonic Wave on the Characteristics of Tree Growth and Dielectric Loss in Polymer Insulation Material)

  • 전춘생;김원식;김상현;박원규
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1242-1251
    • /
    • 1991
  • This paper is to investigate the tree growth phenomena and the characteristics of $\varepsilon$' and tan$\delta$ for the effect of ultrasonic wave on polymer insulation material. The conclusions are as follows. 1) As the pressure amplitude of ultrasonic wave is larger and its irradiated time is longer, tree inception voltage and its breakdown voltage in specimen are smaller, and tree growing is faster. 2) As the irradiated quantity of ultrasonic wave is more increased, the value of tan$\delta$ is larger, but the value of $\varepsilon$' is almost constant. 3) The effect by the pressure amplitude of ultrasonic wave is greater than that by its irradiated time on the insulation characteristics of polymer material.

Experimental Investigation on Dielectric and Thermal Characteristics of Nanosized Alumina Filler Added Polyimide Enamel

  • Sugumaran, C. Pugazhendhi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.978-983
    • /
    • 2014
  • The polymer nano composite possess good priority recently for engineering applications. Especially the electrical insulating materials attract the high performance of nano composites. In this work the ballmill synthesiation process of nano sized Alumina ($Al_2O_3$), the preparation of new nano composite material with an content of enamel and synthesized Alumina as 1wt%, 3wt% and 5wt%. Experimental investigation has been carried out for the prepared nano composites materials with respect to dielectric parameter measurements such as dielectric loss (tan ${\delta}$), dielectric constant (${\varepsilon}$), dielectric strength under various temperature. The partial discharge level also measured for all the samples and the PD inception voltage is also observed and compared. Weight loss of the material has been analyzed through TGA. It has been experimentally proved that 3wt% of Alumina nano filler added enamel has significant improvement in the dielectric and thermal properties.

77K 이하 극저온 상에서의 부분방전 특성 분석 (Analysis of Partial Discharge Characteristics at Cryogenic Temperature below 77K)

  • 이상화;김복렬;신우주;이방욱;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1562-1563
    • /
    • 2011
  • Partial discharge measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. Recently partial discharge diagnostic techniques were also utilized to evaluate the cryogenic dielectric insulation of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used used as the cryogenic and dielectric media for many high temperature superconducting high voltage applications. When a quench in the superconductor occurs, bubbles are generated which can affect the dielectric properties of the liquid nitrogen. So in order to reduce the bubble formation, subcooled nitrogen was also employed for this purpose. In this work, investigation of partial discharge characteristics of subcooled liquid nitrogen were conducted in order to clarify the retardation of partial discharge initiation voltage according to the different subcooling temperature of liquid nitrogen. And also the relation of partial discharge phenomena and the activities of bubbles were analyzed. It was observed that PD inception voltages shows rather different characteristics according to the decrease of subcooling temperature and the activities of bubbles were strongly influenced by temperature of the subcooled liquid nitrogen.

  • PDF

PD Occurrence Characteristics according to Voltage and Time in Solid Insulator

  • Park, Sung-Hee;Shin, Dal-Woo;Lim, Kee-Joe;Park, Young-Guk;Kang, Sung-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권1호
    • /
    • pp.10-14
    • /
    • 2003
  • The occurrence of partial discharge (PD) in solid dielectrics is very harmful because it leads to the deterioration of insulation by electrical, chemical, and thermal reactions as a combined action of the discharged ions bombarding the surface and by the action of chemical compounds that are formed by the discharge. Consequently, if any defects are present in the solid insulation system, performance decreases until the system breaks down. Therefore, removing or suppressing the defect is very important. Voids are a typical defect in the solid insulation system and are very harmful because they deteriorate insulation. As a basic step, studying the properties of PD in voids is important because an accurate knowledge of these properties is required to estimate the deterioration of voids. In this paper, the correlation between the size of voids and internal PD is discussed as a function of the time of the applied voltage and its magnitude. Magnitude, repetition rate, average discharge power, and average discharge current of PD in specimens with large voids were found to be larger than the others in this experiment. The smaller specimens had voids when the magnitude and number of PDs were reduced.