• 제목/요약/키워드: Inception voltage

검색결과 104건 처리시간 0.028초

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

고온 초전도 레이블의 절연 특성 (Insulation Characteristics of High Temperature Superconducting Cable)

  • 김해준;김재호;심기덕;김해종;조전욱;성기철;곽동순;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.244-247
    • /
    • 2004
  • The electrical insulating design is important to realize a HTS power cable because the cable is operated under the high voltage environment. For the insulation design of a HTS power cable, it is necessary to investigate the AC, impulse breakdown and partial discharge(PD) inception stress of liquid nitrogen/LPP composite insulation system. Based on these results, the electrical insulation of a HTS power cable is designed and Mini-model cables are manufactured. The manufactured Mini-model cables are evaluated that AC, impulse withstand voltage, breakdown and partial discharge inception stress and analyzed characteristics insulation of HTS cable bending condition according to this paper. From these tests, the AC, impulse withstand voltage test and partial discharge inception stress is satisfied "standard technical specification of KEPCO" in Korea and the breakdown voltage was 120kV.

  • PDF

$SF_6$ 가스 중의 삼중점 절연파괴 예측기술에 관한 연구 (Study on Insulation Prediction of Triple Junction in $SF_6$)

  • 조용성;정진교;이우영
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.989-993
    • /
    • 2009
  • Triple junction which consists of three media(electrode, insulator, and gas) should be considered in designing of high voltage equipments due to the electric field enhancement. In this paper, positive lightning impulse breakdown voltage is predicted based on the streamer theory for simplified insulator models and 72.5kV spacer with varying the triple junction geometry and gas pressure, and the results are compared to the experimental results. The electric field coefficient concept is also applied in order to evaluate the partial discharge inception voltage and the surface flashover voltage from the streamer inception voltage. The application of this method using the constant electric field coefficient of 1.3 and 0.66 is possible for evaluating the triple-junction insulation of the simplified insulator and the 72.5kV spacer respectively. The error rate is under 10%.

불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성 (Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

Dependence of the Partial Discharge Characteristics of Ultra-high Voltage Cable Insulators on the Measuring Temperature

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Hyuk-Jin;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.186-192
    • /
    • 2008
  • Cross linked polyethylene (XLPE) insulators are used as insulation in ultra-high voltage electric power cables. This study investigated the electrical properties of XLPE at different temperatures. The electrical properties of the changing tree phenomenon was examined as a function of temperature applied to the electrical conductors by measuring the partial discharge at $25^{\circ}C$ to $80^{\circ}C$ and applied voltages to the electrodes ranging from 1 kV to 40 kV. The activity of the partial discharge was examined at various temperatures using the K-means distribution. The results revealed the specimen at $80^{\circ}C$ to have the lowest inception voltage and breakdown voltage. In addition, the core of clusters was moved $0^{\circ}$ and $180^{\circ}$ at the positive region and $180^{\circ}$ and $360^{\circ}$ in the negative region in the K-means. The distribution of clusters was concentrated on the inception condition and spread out widely at the breakdown voltage.

인버터 구동형 저압 유동전동기의 절연특성 분석 (Analysis of Insulation Characteristics of Low-Voltage Induction Motors Fed by Pulse-Controlled Inverters)

  • 박도영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2000
  • In this paper the insulation characteristics test results of 25 low-voltage induction motors($3\phi$, 5HP, 380V) are presented. Five different types of insulation techniques are applied to 25 motors. The maximum partial discharge (PD) magnitude ($\textrm{Q}_{m}$) discharge inception voltage (DIV) dissipation factor tip-up ($\Delta$tan$\delta$) and rate of change in AC current($\Delta$I) are measured by PD and AC current tests. Also the insulation breakdown tests by high voltage pulse are performed and the corresponding breakdown voltage are obtained.

  • PDF

친환경 고전압 전력기기 개발을 위한 GN2의 절연특성 분석 (Analysis on the Dielectric Characteristics of Gaseous Nitrogen for Developing Eco-friendly High Voltage Apparatuses)

  • 방승민;이온유;김준일;강종오;이홍석;고태국;강형구
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.356-360
    • /
    • 2014
  • The environmental pollution caused by green-house gases such as $SF_2$ has been becoming the main issue of industrial society. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions [1]. Therefore, a study on the dielectric characteristics of the $GN_2$ is important for designing a eco-friendly high voltage apparatuses. In this paper, to develop an electrically reliable, stable, and eco-friendly high voltage apparatus, the breakdown voltage and partial discharge inception voltage characteristics in $GN_2$ considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. Also, the dielectric characteristics of the $GN_2$ are analyzed by using a Finite Elements Method (FEM) according to various field utilization factors. The results are expected to be applicable to designing the high voltage apparatuses using $GN_2$ as an insulation gas.

NaCl에 의한 PVC 케이블의 부분방전 열화 특성에 관한 연구 (A Study on Partial Discharge Degradation Properties of PVC Cable due to NaCl)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.636-641
    • /
    • 2015
  • In this study, the partial discharge degradation properties for 2-core PVC cable($2cores{\times}1.5mm^2$ cross section, length of 10 cm, 20 cm, 30 cm) following immersion with the salt water that the 2%, 4%, 8% of NaCl is dissolved in 100 g of distilled water for 48 and 96 hours has been measured. The results of this study are as follows. When the degradation time in salt water of 2% NaCl is 48 hours, it found that the number of partial discharge increased as about 40 pps, 50 pps, 90 pps with increasing the length of cable to 10 cm, 20 cm, 30 cm. In case the concentration and degradation time is same, the inception and extinction voltage decreased with increasing the length of cable. When the degradation time in salt water is 96 hours and the length of cable is 20 cm, it found that the number of partial discharge decreased as 3,000 pps, 500 pps, 100 pps with increasing the concentration of NaCl to 2%, 4%, 8%.

실리콘 고무의 부분방전 특성에 관한 연구 (A Study on Properties of Partial Discharge in Silicone Rubber)

  • 이성일;권영천
    • 한국전기전자재료학회논문지
    • /
    • 제24권11호
    • /
    • pp.890-894
    • /
    • 2011
  • In this thesis, the silicone filler with a sample size of 0~75 phr and void size of 2~4.5 mm is prepared in order to diagnose the defect of void which exists in widely used insulation material, silicone rubber. In this silicone rubber sample, electrodes are connected and whilst the voltage changes, applied voltage 7 kV~9 kV is increased constantly over time and discharge quantity, discharge frequency and applied voltage (T-QNV) were measured. The discharge quantity of the applied voltage (VQ) is measured to estimate inception voltage and extinction voltage. In addition, under the condition of maintaining constant applied voltage, discharge quantity and discharge frequency (QN) are measured, and its characteristics are analyzed.

A Study on the Insulation Characteristics for Stator Windings of IGBT PWM Inverter-Fed Induction Motors

  • Hwang, Don-Ha;Kang, Dong-Sik;Kim, Yong-Joo;Lim, Tae-Hoon;Bae Sung-Woo;Kim Dong-Hee;Ro Chae-Gyun
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.159-166
    • /
    • 2003
  • The winding insulation of low-voltage induction motors in adjustable-speed drive system with voltage-fed Inverters is substantially stressed due to the uneven voltage distribution and excessive voltage stress (dv/dt), which result in the premature insulation breakdown In this paper, the detailed insulation test results of 26 low-voltage induction motors are presented. Six different types of insulation techniques are applied to 26 motors. The insulation characteristics are analyzed with partial discharge, discharge inception voltage, AC current, and dissipation factor tests Also, insulation breakdown tests by high voltage pulses are performed, and the corresponding breakdown voltages obtained.