• 제목/요약/키워드: Incandescent electric lamp

검색결과 25건 처리시간 0.058초

백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측 (Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp)

  • 이흥수;김두현
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

220V/100W 백열전구의 온도특성에 따른 화재분석에 관한 연구 (A Study on Fire Analysis According to Temperature Characteristics of an Incandescent Electric Lamp at 220V/100W)

  • 송길목;한운기;김영석;최충석
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.43-49
    • /
    • 2006
  • 본 논문은 조명설비 중 220V/100W 백열전구의 온도특성과 화재분석에 관하여 연구하였다. 백열전구의 발열에 의한 발화가능성을 실험한 결과 정상상태에서는 최고 $161.9^{\circ}C$로 측정되었다. 밀폐된 공간에서 축 열이 되면 약 $538.1^{\circ}C$까지 상승하는 것으로 나타났다. 유리구를 파손하였을 경우 필라멘트는 공기 중에서 용단되었다. 외부 열에 의한 경우 전구 내부의 가스가 약한 부분으로 분출되었다. 따라서 백열전구는 산소의 공급이 원활하면서 폐쇄된 공간에서 화재의 가능성이 높으며, 가연성 물질 등이 주변에 있다면 화재 가능성이 매우 높은 것으로 나타났다. 백열전구의 외형변화, 재료특성의 변화 등을 통해 화재원인을 규명하는 중요한 자료로 이용될 것이 기대된다.

전기조명의 사회기술전환 연구 : 백열램프에서 형광램프로 (A Study on the Socio-Technical Transition in Electric Lighting : from Incandescent Lamp to Fluorescent Lamp)

  • 김재일;이희상
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.8-21
    • /
    • 2015
  • Technology for electric lighting has been evolving from Incandescent Lamp(IL) through Fluorescent Lamp(FL) and currently to Solid State Lighting(SSL) such as LED for more than 130 years of time. However, it took more than 100 years until the transition from IL to FL across overall society. That is because the transition is the Socio-Technical Transition(STT) which involves various social elements. This study investigated and analyzed the theories regarding STT, and applied the Multi-Level Perspective(MLP) theory to the case of electric lighting. A qualitative contents analysis was used with secondary data as research method, and the analyzed result was visualized based on the frame of MLP theory. The STT of electric lighting from IL to FL took place as the order of Technical Niche, Socio-Technical Regime and Landscape. Specifically, in Technical Niche level: Establishing Market Niche, Price-Performance Improvement, Learning Process and Support of Powerful Group took place. In Socio-Technical Regime level: Changes in Social Network, Changes in Technology and Changes in Rules. In Landscape level: Macro-Political Development, Socio-Economic Trends and Macro-Economic Trends took place in consecutive order.

해상용 LED(Light Emitting Diode) 등명기 연구개발 (A Study on the Marine Lattern Development using Light Emitting Diodes)

  • 정학근;정봉만;한수빈;유승원;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.167-170
    • /
    • 2004
  • A high light lantern system using LEDs is composed of power supply, flash controller, and daylight controller and proper case considering work condition. The performance of developed LED lantern is better than that of the existing marine lantern using an incandescent electric lamp and that of foreign products(Vega LED lantern made in New Zealand, Tideland system made in America). The electric consumption of our products is 30% compared with that of existing marine lantern using an incandescent electric lamp, and the luminous Intensity of them is 200% to 400% compared with that of existing marine lantern and foreign LED lantern. In addition, our LED lantern system is easy to repairing something wrong and changing the LED module and other controllers on the sea when they are in accident.

  • PDF

AC/DC 겸용 비상 및 복구등에 관한 연구 (A Study on the emergency and repairing AC/DC combination lamp)

  • 안윤기;최홍규;최준영;이정열
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.19-25
    • /
    • 2009
  • 본 연구는 변전소(사무실) 설비 환경 개선 차원으로 기존 비상등하에서 조도 부족으로 인한 근무자의 오조작 및 복구 시간 지연을 단축하기 위하여 현재 설치된 등기구의 형태를 백열등에서 형광등으로 대체하였으며, AC/DC 겸용 비상등 및 스위치에 관하 연구하였다. 조도 기준 또한 상시등의 5${\sim}$10[%] 가 아닌 한국 산업 조도 기준(KSA)에 따른 원자력 발전소 조도 기준 및 안전 조명에 의한 조도 기준을 참고로 정확한 변전소 각 실별 조도 기준을 책정하였고 그에 따른 변전소 내선 전기 설계를 표준화하였다. 또한 배터리 용량 산정 기준과 중요도에 따른 각 실별 등기구 설치 수량을 표준화하여 조도 부족으로 인한 2차 사고나 광역 정전 사고로 인한 대형 사고를 방지하고자한다.

  • PDF

전동차의 전력품질저하에 따른 광플리커 현상에 관한 연구 (Study of Light Flickering according to the Degradation of Power Quality in the electric train)

  • 최영하;이강원;김명룡;온전근;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1410-1412
    • /
    • 2004
  • Light flickering is caused by the degradation of power quality in electric train and can be measured by electronic illuminometer. This paper has shown the relations between voltage variations and illumination of lamps which has two kinds of incandescent lamp and 3-wavelength fluorescent lamp.

  • PDF

저압배선계통에서 직렬아크의 검출에 관한 연구 (A Study on the Series Arc Detection in Low-voltage Wiring Systems)

  • 김일권;박대원;최수연;박찬용;김황국;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.182-187
    • /
    • 2008
  • This paper dealt with the detection algorithm of series arcing, which is a cause of electric fires in low-voltage wiring systems. To find the distinguished electrical features of series arc, we simulated series arcing by the arc generator specified in UL1699. An electric heater, an inverter-controlled vacuum cleaner, and a phase-controlled incandescent lamp were used as loads to generate series arcing. A high-pass filter (HPF) with the low cut-off frequency of 3 kHz at -3 dB was fabricated and applied to separate the series arc signal from the AC voltage source. The experiment showed that the high frequency signal generates randomly during series arcing, and the phase-controlled incandescent lamp produces high frequency pulses even in normal state. In this case, the magnitude, the width, and the randomness of high frequency signal should be analyzed to estimate series arcing precisely.

조명등 화재사례 연구(전구 및 형광등 중심으로) (A Case Study on the Lights Fire(Focus on the Electric Bulbs and Fluorescent Lamps))

  • 송태현;이의평
    • 한국화재조사학회논문지
    • /
    • 제11권1호
    • /
    • pp.41-58
    • /
    • 2008
  • 등불의 발견은 인간 생활에 커다란 변화를 가져 왔으며, 그 역사는 매우 오래되었다. 그러나 비약적으로 발전한 것은 1879년 에디슨이 탄소 필라멘트 진공 전구를 발명하여 조명에 사용하면서 시작되었다고 할 수 있다. 조명은 피로를 덜어주고 안전도를 높이며 사람의 활동 능률을 올리고 즐거운 분위기를 만들어 준다. 그러나 부주의나 관리소홀로 인해 소중한 재산과 인명을 앗아가는 화재의 원인이 되기도 한다. 본 연구에서는 조명등의 구조와 원리를 이해하고 일반가정에서 가장 많이 사용되고 있는 백열전구과 형광등을 중심으로 출화가능성과 조사확인사항에 대하여 발화사례를 중심으로 하여 배선과 가연물 접촉에 의한 사례 및 재현실험을 통하여 논문의 신뢰성을 확보하고자 하였다.

  • PDF

효율적 시공을 위한 라이트웨이 조명등기구의 작업지시서 개발 (Development of Light-Way Lighting Appliance of Specifications for Efficient Construction)

  • 최충석;고재완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.18-22
    • /
    • 2009
  • In this paper, we are develop specifications light-way lighting appliance for efficient construction. Analyzed wide application and connection regulation. Also, flickering circuit Presented separation, arrangement, mounting instruction. Incandescent lamp occurs much heat. Therefore, establishment of enough electric light interval is required. Voltage of discharge lamp does by below 300v, and provide so that a person is not can may touched.

  • PDF