• 제목/요약/키워드: In-situ measurements

검색결과 524건 처리시간 0.025초

Development of the Bio-Optical Algorithms to Retrieve the Ocean Environmental Parameters from GOCI

  • Ryu, Joo-Hyung;Moon, Jeong-Eon;P., Shanmugam;Min, Jee-Eun;Ahn, Yu-Hwan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.82-85
    • /
    • 2006
  • The Geostationary Ocean Color Imager (GOCI) will be loaded in Communication, Ocean and Meteorological Satellite (COMS). To efficiently apply the GOCI data in the variety of fields, it is essential to develop the standard algorithm for estimating the concentration of ocean environmental components (, , and ). For developing the empirical algorithm, about 300 water samples and in situ measurements were collected from sea water around the Korean peninsula from 1998 to 2006. Two kinds of chlorophyll algorithms are developed by using statistical regression and fluorescence technique considering the bio-optical properties in Case-II waters. The single band algorithm for is derived by relationship between Rrs (555) and in situ concentration. The CDOM is estimated by absorption coefficient and ratio of Rrs(412)/Rrs(555). These standard algorithms will be programmed as a module of GOCI Data Processing System (GDPS) until 2008.

  • PDF

Surface Characterization of Carbon Fibers as Anode Materials for Li Secondary Batteries

  • Takamura, Tsutomu;Awano, Hidekazu;Ura, Tetsuya;Ikezawa, Yasunari
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.583-590
    • /
    • 1995
  • Pitch-based mesophase carbon fibers prepared at different temperatures were heat-treated at temperatures lower than those of the preparation and the electrochemical Li doping/undoping characteristics were evaluated in relation to the data of IR, mass, etc. Presence of surface hydroxyls were confirmed by FTIR for lower temperature sample which showed poor anode characteristics. Upon oxidative heating, removal of surface hydroxyls took place, resulting in a remarkable improvement of the electrode characteristics. At the same time, surface roughening took place, which was confirmed by SEM and double layer capacity measurements. In situ mass spectra obesrved during the heat-treatments showed gas evolution of $H_2O$, CO, $CO_2$, $C_2H_4$, and/or $H_2$ depending on the conditions. These data together with those of weight loss and conductivity provided us a valuable information in regard to the evaluation of the electrochemical characteristics.

  • PDF

폐광산의 토양오염영역 및 폐기된 광미의 탐지 (Geophysical Applications on the Soil-contamination Mapping and Detection of Buried Mine Tailings in the Abandoned Mine Area)

  • 이상규;황세호;이태섭
    • 자원환경지질
    • /
    • 제30권4호
    • /
    • pp.371-377
    • /
    • 1997
  • This paper presents the geophysical applications to the environmenml problem in an abandoned mine area. We would like to focus our attention on the mapping of the soil contamination and the detection of the buried mine tailings. For mapping the soil contamination. measurements of both in-situ magnetic susceptibility (k) and terrain conductivity were carried out. In-situ magnetic susceptibilities of the contaminated soil due to the acid mine drainage show higher values than those of the uncontaminated area. However. those data do not show the correlation with the degree of the soil contamination observed on the surface. The least-squares fitted formula obtained with the measured insitu magnetic susceptibilities is $k=4.8207{\times}W^{0.6332}$, where W is the $Fe^{+2}$ weight percentage. This weight gives most effect to magnetic susceptibility of the soil. Lateral variations of the soil contamination in the shallow subsurface can be detected by the electrical conductivity distributions from EM induction survey. TDIP (Time Domain Induced Polarization) and EM induction surveys were conducted to detect the buried mine tailings. From the results of TDIP, the spatial zone, which shows high chargeability-low resistivity, is interpreted as the buried mine tailings. Therefore, it is concluded that it is possible to discriminate the spatial zone from the uncontaminated ground.

  • PDF

공내재하시험기를 이용한 미소변형 전단탄성계수 측정 (Measurement of Small-Strain Shear Modulus Using Pressuremeter Test)

  • 김동수;박재영;이원택
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.109-120
    • /
    • 1997
  • 공용하중 상태에서 지반이 경험하는 변형률 크기는 0.1~1% 미만임이 밝혀지고 있다. 변형특성을 보다 엄밀히 평가하기 위하여는 미소변형률 영역에서의 신뢰성 있는 변형측정이 가능한 현장시험기기의 개발이 필요하다. 본 연구의 목적은 공내째하시험기(PMT)를 사용하여 지반의 미소변형률 전단탄성계수를 측정하는 것이다. 공내재하시험에서 시추공 설치에 따른 주위 지반의 교란효과를 제거하기 위하여 초기 하중재하단계가 아닌 역재하-재재하 단계에서 PMT 주위지 반의 응력상태 및 변형률 크기를 고려하여 미소변형률 잔단탄성계수를 결정하였다. 실내 토조에서 성형한 모래시료와 화강풍화토 현장지반에서 시험을 수행하였으며,시험결과로부터 본 연구 에서 사용한 PMT시험은 변형률 크기 10-2%~0.5% 범위에서 신뢰성 있는 전단탄성계수 측정이 가능하였다. 또한 변형률 크기를 고려하여 다른 실내외시험에서 결정된 전단탄성계수와 비교 하면 서로 잘일치하는 결과를 얻을 수 있었다.

  • PDF

4D full-field measurements over the entire loading history: Evaluation of different temporal interpolations

  • Ana Vrgoc;Viktor Kosin;Clement Jailin;Benjamin Smaniotto;Zvonimir Tomicevic;Francois Hild
    • Coupled systems mechanics
    • /
    • 제12권6호
    • /
    • pp.503-517
    • /
    • 2023
  • Standard Digital Volume Correlation (DVC) approaches are based on pattern matching between two reconstructed volumes acquired at different stages. Such frameworks are limited by the number of scans (due to acquisition duration), and time-dependent phenomena can generally not be captured. Projection-based Digital Volume Correlation (P-DVC) measures displacement fields from series of 2D radiographs acquired at different angles and loadings, thus resulting in richer temporal sampling (compared to standard DVC). The sought displacement field is decomposed over a basis of separated variables, namely, temporal and spatial modes. This study utilizes an alternative route in which spatial modes are con-structed via scan-wise DVC, and thus only the temporal amplitudes are sought via P-DVC. This meth-od is applied to a glass fiber mat reinforced polymer specimen containing a machined notch, subjected to in-situ cyclic tension, and imaged via X-Ray Computed Tomography. Different temporal interpolations are exploited. It is shown that utilizing only one DVC displacement field (as spatial mode) was sufficient to properly capture the complex kinematics up to specimen failure.

Plastic scintillator beta ray scanner for in-situ discrimination of beta ray and gamma ray radioactivity in soil

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1259-1265
    • /
    • 2020
  • A beta ray scanner was proposed for in-situ discrimination of beta and gamma ray radioactivity. This scanner is based on the principle that gamma and beta rays experience different changes in detection efficiency in scintillators with different geometries, especially with regard to the scintillator thickness. The ratios of the counting rates of gamma rays (Rgamma), beta rays (Rbeta), and sample measurements (Rtotal) in a thick scintillator to those in a thin one are reported. The parameter Xthick, which represents the counting rate contributed by beta rays to the total counting rate in the thick scintillator, was derived as a function of those ratios. The values of Rgamma and Rbeta for 60Co and 90Sr sources were estimated as 3.2 ± 0.057 and 0.99 ± 0.0049, respectively. The estimated beta ray contributions had relative standard deviations of 2.05-4.96%. The estimated range of the beta rays emitted from 90Sr was 19 mm as per the Monte Carlo N-Particle simulation, and this value was experimentally verified. Homogeneous and surface contaminations of 60Co and 90Sr-90Y were simulated for application of the proposed method. The counting rate contributed by the beta rays was derived and found to be proportional to the concentration of 90Sr-90Y contamination.

기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구 (The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment)

  • 김서훈;김종훈;류승환;정학근;송규동
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

공벽변형법에 의한 이방성 암반의 초기응력 측정에 관한 연구 - 횡등방성 암석에 대한 실험실 모형 실험 및 수치해석 (A study on the In-situ Stress Measurement of Anisotropic Rocks by Leeman Method - An Experimental and Numerical Simulation on Transversely Isotropic Rock)

  • 민기복;이정인;최해문
    • 터널과지하공간
    • /
    • 제12권4호
    • /
    • pp.237-247
    • /
    • 2002
  • 암반의 이방성이 초기응력 측정결과에 미치는 영향을 살펴보기 위하여 현지암반의 응력 상태를 실험실에서 이축상태로 재현하여 초기응력 측정을 실시하였다. 이축가압장치는 플랫잭(flat jack)을 이용하여 제작하였으며, 등방성과 이방성 암석, 모르타르 및 인공이방성 암석 등 4 종류의 시료에 대하여 총 18회의 초기응력 측정을 실시하였다. 초기응력 측정 결과 이방성을 고려한 경우가 고려하지 않은 경우에 비해 최고 34%의 차이가 발생함으로써 이방성을 고려한 초기응력 측정이 필요함을 확인하였다. 또한 3차원 유한차분해석 프로그램인 FLAC 3D를 이용하여 오버코어링에 따른 응력개방곡선의 적합성에 대한 분석을 실시하여 실험실 모형실험의 결과가 수치해석에 의한 결과와 유사함을 확인하였다.

항공기 구름 관측에 사용되는 전방산란 관측 기기의 정확도 향상을 위한 구름입자의 광학적 특성 계산 (Calculations of Optical Properties of Cloud Particles to Improve the Accuracy of Forward Scattering Probes for In-Situ Aircraft Cloud Measurements)

  • 엄준식
    • 대기
    • /
    • 제30권1호
    • /
    • pp.75-89
    • /
    • 2020
  • Current in-situ airborne probes that measure the sizes of ice crystals smaller than 50 ㎛ are based on the concept that the measured intensity of light scattered by a particle in the forward and/or backward direction can be converted to particle size. The relationship between particle size and scattered light used in forward scattering probes is based on Mie theory, which assumes the refractive index of particle is known and all particles are spherical. Not only are small crystals not spherical, but also there are a wide variety of non-spherical shapes. Although it is well known that the scattering properties of non-spherical ice crystals differ from those of spherical shapes, the impacts of non-sphericity on derived in-situ particle size distributions are unknown. Thus, precise relationships between the intensity of scattered light and particle size and shape are required, as based on accurate calculations of scattering properties of ice crystals. In this study, single-scattering properties of ice crystals smaller than 50 ㎛ are calculated at a wavelength of 0.55 ㎛ using a numerically exact method (i.e., discrete dipole approximation). For these calculations, hexagonal ice crystals with varying aspect ratios are used to represent the shapes of natural small ice crystals to determine the errors caused by non-spherical ice crystals measured by forward scattering probes. It is shown that the calculated errors in sizing nonspherical ice crystals are at least 13% and 26% in forward (4~12°) and backward (168~176°) directions, respectively, and maximum errors are up to 120% and 132%.

연료전지용 고분자전해질막의 실시간 수소 투과도 측정법 연구 (The Study on In-situ Measurement of Hydrogen Permeability through Polymer Electrolyte Membranes for Fuel Cells)

  • 임윤재;이창현
    • 멤브레인
    • /
    • 제26권2호
    • /
    • pp.141-145
    • /
    • 2016
  • 고분자전해질막은 전극 이외에 전기 화학 연료전지의 성능을 결정하는 중요한 요소이다. 고분자전해질막은 가스나 양성자 등의 작은 분자를 선택적으로 수송해야 한다. 고분자전해질막을 투과한 가스는 급속히 전기 화학적 환원을 발생시켜 음극 촉매의 열화를 유발하기 때문에 수소 장벽으로 작동해야 하며 가능한 한 빨리 양성자를 이동시켜야 한다. 지금까지 고분자전해질막의 수소 기체 투과도를 측정하는데 한정된 방법(예 : Constant volume/variable pressure (Time-lag)법)을 사용했다. 그러나 측정의 대부분은 고분자전해질막은 건조된 진공 하에서 이루어진다. 그렇지 않으면 얻어진 수소 투과도는 측정 오차가 커지는 원인이 되기 쉽다. 이 연구에서는 일반적으로 고분자전해질막으로 사용되는 Nafion212의 수소 가스 투과 특성을 온도와 습도가 동시에 제어되는 in-situ 측정 시스템을 이용하여 평가하였다.