• Title/Summary/Keyword: In-situ diagnosis

Search Result 149, Processing Time 0.031 seconds

Carcinoma in Situ of the Urinary Bladder in Bladder Washing Cytology (방광 상피내암의 뇨 세포학적 소견)

  • Chung, Doo-Hyun;Park, In-Ae;Ham, Eui-Keun
    • The Korean Journal of Cytopathology
    • /
    • v.2 no.1
    • /
    • pp.51-55
    • /
    • 1991
  • The diagnosis of carcinoma in situ of urinary bladder is difficult in that the symptoms and cystoscopic findings are nonspecific. The cytology of urine could be helpful for diagnosis of carcinoma in situ of urinary bladder. We present a case of bladder washing cytology of carcinoma in situ. A 54-year-old man presented with dysuria for 1 year. Cystoscopic findings revealed multifocal reddish trabeculated lesions. The bladder washing cytology revealed rather uniform tumor cells which were singly scattered of forming syncytium in the clean back-ground. The nuclei were round to oval with inconspicious nucleoli. The cystoscopic biopsy revealed typical histologic features of carcinoma in situ of urinary bladder.

  • PDF

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

Retrospective study of porcine epidemic diarrhea in Korea by in situ hybridization (In situ hybridization에 의한 돼지 유행성 설사증의 국내발생 역추적 진단)

  • Park, Nam-yong;Lee, Seok-yun
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.4
    • /
    • pp.809-816
    • /
    • 1997
  • In this presented study, we established a method for diagnosis of porcine epidemic diarrhea(PED) by in situ hybridization(ISH), which made distinct progress in diagnostic pathology. We also carried out the retrospective diagnosis through ISH to assume the exact time of the first outbreak and incidence of PED in Korea. The outbreak of PED in Korea reported in 1992. However, since the end of 1980's, some researches of pig-industry have already suspected the outbreak of PED, not transmissible gastroenteritis(TGE). In this experiment, we performed the ISH using 80 formalin-fixed and paraffin-embedded tissues of porcine intestine which were requests for pathological diagnosis from 63 farms whose primary sign was diarrhea from 1984 to 1991. We prepared biotinylated cDNA probe(492base pairs) for ISH by nick translation method and carried out the ISH, using $Microprobe^{TM}$ capillary action system(Fisher $Biotech^R$). We detected PED virus in intestinal mucosa of 2 cases in 1992, 1 case in 1988, and 1 case in 1987. As a result, we assume that the outbreak of PED in Korea have already started since 1987.

  • PDF

APPLICATION OF MONITORING, DIAGNOSIS, AND PROGNOSIS IN THERMAL PERFORMANCE ANALYSIS FOR NUCLEAR POWER PLANTS

  • Kim, Hyeonmin;Na, Man Gyun;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.737-752
    • /
    • 2014
  • As condition-based maintenance (CBM) has risen as a new trend, there has been an active movement to apply information technology for effective implementation of CBM in power plants. This motivation is widespread in operations and maintenance, including monitoring, diagnosis, prognosis, and decision-making on asset management. Thermal efficiency analysis in nuclear power plants (NPPs) is a longstanding concern being updated with new methodologies in an advanced IT environment. It is also a prominent way to differentiate competitiveness in terms of operations and maintenance costs. Although thermal performance tests implemented using industrial codes and standards can provide officially trustworthy results, they are essentially resource-consuming and maybe even a hind-sighted technique rather than a foresighted one, considering their periodicity. Therefore, if more accurate performance monitoring can be achieved using advanced data analysis techniques, we can expect more optimized operations and maintenance. This paper proposes a framework and describes associated methodologies for in-situ thermal performance analysis, which differs from conventional performance monitoring. The methodologies are effective for monitoring, diagnosis, and prognosis in pursuit of CBM. Our enabling techniques cover the intelligent removal of random and systematic errors, deviation detection between a best condition and a currently measured condition, degradation diagnosis using a structured knowledge base, and prognosis for decision-making about maintenance tasks. We also discuss how our new methods can be incorporated with existing performance tests. We provide guidance and directions for developers and end-users interested in in-situ thermal performance management, particularly in NPPs with large steam turbines.

The Study on In-situ Diagnosis of Chemical Vapor Deposition Processes (화학기상증착 진공공정의 실시간 진단연구)

  • Jeon, Ki-Moon;Shin, Jae-Soo;Lim, Sung-Kyu;Park, Sang-Hyun;Kang, Byoung-Koo;Yune, Jin-Uk;Yun, Ju-Young;Shin, Yong-Hyeon;Kang, Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • The diagnosis studies of the process of chemical vapor deposition were carried out by using in-situ particle monitor (ISPM) and self-plasma optical emission spectroscopy (SPOES). We used the two kinds of equipments such as the silicon plasma enhanced chemical vapor deposition system with silane gas and the borophosphosilicate glass depositon system for monitoring. Using two sensors, we tried to verify the diagnostic and in-situ sensing ability of by-product gases and contaminant particles at the deposition and cleaning steps. The processes were controlled as a function of precess temperature, operating pressure, plasma power, etc. and two sensors were installed at the exhaust line and contiguous with each other. the correlation of data (by-product species and particles) measured by sensors were also investigated.

In situ culture and harvest of aminocytes using covership processing method

  • Cheong, Kyung-Soon;Hwang, Do-Yeong;Lee, Dong-Sook;Cho, Soo-Kyung;Kim, Ki-Chul;Min, Eung-Gi
    • Journal of Genetic Medicine
    • /
    • v.2 no.2
    • /
    • pp.79-81
    • /
    • 1998
  • Genetic amniocenteses were performed in a series of 127 patients as a routine study. Samples from the patients were cultured by in situ method, flask method or both according to the state of amniotic fluid. The overall success rate of culture was 97.6% and no culture failure was observed in the flask method. It took 5 days first of all and 8.15 days average from set-up to harvest and there were 7.2 colonies per dish in in situ method. Therefore, it is suggested that in situ method which decreased the mean culture days and made clonal analyses possible, is a clinically available and even more reliable method in parallel with flask method in prenatal diagnosis.

  • PDF

Plasma Diagnosis by Using Scanning Electron Microscope and Neural Network (신경망과 주사전자현미경을 이용한 플라즈마 진단)

  • Bae, Jung-Gi;Kim, Byung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.96-98
    • /
    • 2006
  • A new ex-situ model to diagnose a plasma processing equipment was presented. The model was constructed by combining wavelet, scanning electron microscope, ex-situ measurement of etching profile, and neural network. The diagnosis technique was applied to a tungsten etching process, conducted in a $SF_6$ helicon plasma. The wavelet was used to characterize detailed variations of plasma-etched surface. The diagnosis model was constructed with the vertical wavelet component. For comparison, a conventional model was built by using the estimated profile data. Compared to the conventional model, the wavelet-based model, demonstrated a much improved diagnosis.

  • PDF

Digoxigenin-labeled in situ Hybridization for Diagnosis of Aujeszky's disease in Pigs (Digoxigenin-labeled in situ Hybridization을 이용한 오제스키병의 진단)

  • Kim, Soon-Bok;Moon, Oun-Kyung;Song, Geun-Suk;Yeo, Sang-Geon
    • Korean Journal of Veterinary Pathology
    • /
    • v.1 no.2
    • /
    • pp.119-124
    • /
    • 1997
  • The objective of this study was to develop digoxigenin (DIG)-labeled in situ hybridization (ISH) test for diagnosis of Aujeszky's Disease(AD) in infected organs. Specific DNA with well conserved gene sequences encoding gp50 antigen in AD virus (ADV) was obtained by Polymerase Chain Reaction (PCR) method. A pair of oligonucleotide primers used in PCR allowed amplification of a 217 bp sequence from the gp50 ADV gene. The DNA was then labeled with DIG by primer labeling method for use as probe in ISH test to detect ADV nucleic acids in various tissue. Positive hybridization was demonstrated by dark pigmentation in nuclei and cytoplasm of ADV infected cells particularly in brain tonsillar crypt epithelium and pulmonary alveolar cells. This result suggests that ISH is a valuable sensitive and rapid diagnostic test for AD.

  • PDF

Diagnosis of canine distemper by in situ hybridization (In situ hybridization에 의한 개 디스템퍼의 진단)

  • Cho, Hyeon;Park, Nam-yong;Kim, Yong-hwan;Cho, Kyoung-oh;Park, Hyung-seon;Park, Young-seok;Lee, Bong-joo;Chung, Chi-young;Im, Hyung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.583-592
    • /
    • 1999
  • We have developed the in situ hybridization(ISH) technique for rapid diagnosis of canine distemper(CD) which is the major infectious disease in dogs. In our experiment, we rapidly detected distribution of the specific canine distemper viral genome without disrupting morphology of tissues or cells. Two oligonucleotide probes for ISH were synthesized chemically and labelled 5' end with nonisotopic biotin by DNA synthesizer. The whole procedures of ISH was completed within 1~2 hours using the Microcapillary action system. On histological study, typical cytoplasmic or intranuclear inclusion bodies were observed in the trachea, bronchiole, brain, and urinary bladder with the presence of prominent red positive signals on ISH, indicating specific CDV genome from the paraffin-embedded tissues of infected 13 cases. The results showed ISH can be used as a rapid and effective diagnostic method for diagnosis of CD.

  • PDF

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.