• 제목/요약/키워드: In-situ Calibration

검색결과 108건 처리시간 0.025초

In Situ Gamma-ray Spectrometry Using an LaBr3(Ce) Scintillation Detector

  • Ji, Young-Yong;Lim, Taehyung;Lee, Wanno
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.85-96
    • /
    • 2018
  • Background: A variety of inorganic scintillators have been developed and improved for use in radiation detection and measurement, and in situ gamma-ray spectrometry in the environment remains an important area in nuclear safety. In order to verify the feasibility of promising scintillators in an actual environment, a performance test is necessary to identify gamma-ray peaks and calculate the radioactivity from their net count rates in peaks. Materials and Methods: Among commercially available scintillators, $LaBr_3(Ce)$ scintillators have so far shown the highest energy resolution when detecting and identifying gamma-rays. However, the intrinsic background of this scintillator type affects efficient application to the environment with a relatively low count rate. An algorithm to subtract the intrinsic background was consequently developed, and the in situ calibration factor at 1 m above ground level was calculated from Monte Carlo simulation in order to determine the radioactivity from the measured net count rate. Results and Discussion: The radioactivity of six natural radionuclides in the environment was evaluated from in situ gamma-ray spectrometry using an $LaBr_3(Ce)$ detector. The results were then compared with those of a portable high purity Ge (HPGe) detector with in situ object counting system (ISOCS) software at the same sites. In addition, the radioactive cesium in the ground of Jeju Island, South Korea, was determined with the same assumption of the source distribution between measurements using two detectors. Conclusion: Good agreement between both detectors was achieved in the in situ gamma-ray spectrometry of natural as well as artificial radionuclides in the ground. This means that an $LaBr_3(Ce)$ detector can produce reliable and stable results of radioactivity in the ground from the measured energy spectrum of incident gamma-rays at 1 m above the ground.

공내재하시험기를 이용한 미소변형 전단탄성계수 측정 (Measurement of Small-Strain Shear Modulus Using Pressuremeter Test)

  • 김동수;박재영;이원택
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.109-120
    • /
    • 1997
  • 공용하중 상태에서 지반이 경험하는 변형률 크기는 0.1~1% 미만임이 밝혀지고 있다. 변형특성을 보다 엄밀히 평가하기 위하여는 미소변형률 영역에서의 신뢰성 있는 변형측정이 가능한 현장시험기기의 개발이 필요하다. 본 연구의 목적은 공내째하시험기(PMT)를 사용하여 지반의 미소변형률 전단탄성계수를 측정하는 것이다. 공내재하시험에서 시추공 설치에 따른 주위 지반의 교란효과를 제거하기 위하여 초기 하중재하단계가 아닌 역재하-재재하 단계에서 PMT 주위지 반의 응력상태 및 변형률 크기를 고려하여 미소변형률 잔단탄성계수를 결정하였다. 실내 토조에서 성형한 모래시료와 화강풍화토 현장지반에서 시험을 수행하였으며,시험결과로부터 본 연구 에서 사용한 PMT시험은 변형률 크기 10-2%~0.5% 범위에서 신뢰성 있는 전단탄성계수 측정이 가능하였다. 또한 변형률 크기를 고려하여 다른 실내외시험에서 결정된 전단탄성계수와 비교 하면 서로 잘일치하는 결과를 얻을 수 있었다.

  • PDF

Calibration Chamber System을 이용한 KICT-type LPT 장비의 거동분석 (Evaluation of KICT-type Large Penetration Test using Calibration Chamber System)

  • 김영석;김영진;이우진;안신환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1359-1364
    • /
    • 2008
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760mm and 150kg, respectively. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. In this study, the performance of KICT-type LPT was evaluated by using a calibration chamber system and pile driving analyzer (PDA)

  • PDF

정지궤도 해색탑재체(GOCI) 자료 검정을 위한 사전연구 (Prelaunch Study of Validation for the Geostationary Ocean Color Imager (GOCI))

  • 유주형;문정언;손영백;조성익;민지은;양찬수;안유환;심재설
    • 대한원격탐사학회지
    • /
    • 제26권2호
    • /
    • pp.251-262
    • /
    • 2010
  • GOCI(Geostationary Ocean Color Imager) 표준자료의 지속적인 품질관리를 위해서는 위성 운용기간 중 궤도상 복사보정, 대기보정 단계를 거쳐야 되며 해수환경 분석 알고리즘에 대한 검보정도 지속적으로 이루어져야 한다. GOCI의 복사, 대기, 해양환경 자료에 대한 검보정은 부이나 고정 플랫폼을 이용한 수온, 염분, 해수 광특성, 형광, 및 탁도 관측과, 주기적으로 해양환경 자료 수집을 통하여 실시한다. 이를 위하여 동중국해에 위치하고 있는 이어도 종합해양과학기지에 설치된 광학 관측 장비와 현장 관측의 복사자료를 상호 비교해 보았으며, GOCI 표준자료의 검정에 앞서 SeaWiFS 복사량과 비교하여 검정하였다. 해수출 광량은 현장관측에서 얻어진 광과 광량과는 약간의 차이를 보였지만, 흡광영역이 매우 잘 일치하고 있으며 스펙트럴 이동은 없는 것으로 판단된다. 이어도 종합해양과학기지의 분광측정기와 SeaWiFS의 전 밴드에서 얻어진 해수출 광량을 비교한 결과 평균 25% 정도의 에러가 발생했지만, 대기보정 밴드를 제외하면 절대오차가 11% 정도로 상당히 낮아진다. 이것은 SeaWiFS 표준 대기보정 방법의 문제점으로 GOCI 검보정 연구에서 고려되어 보완 되어야 할 것으로 판단된다. 이와 더불어 독도 지역의 표준 관측치(Reference Target Site) 구축을 통한 검보정 연구를 위하여, 독도 주변 해수의 광 특성과 해양환경 자료는 2009년 8월과 2009년 10월 2차례에 걸쳐서 현장관측을 실시하였다. 독도 주변 해역의 해양 광 특성은 원격반사도의 스펙트럼형태를 기준으로 Case-1 Water 성향이 강한 해수에서 나타나는 특성과 매우 유사하였다. 식물플랑크톤, 부유물질, 용존유기물의 흡광계수 스펙트럼의 형태들은 대체적으로 각 성분별 흡광 스펙트럼 특성을 잘 보여주었다. 또한 MODIS Aqua로부터 산출된 엽록소 농도와 현장관측을 통한 검증에서 위성자료 값들은 잘 일치한다. 위와 같이 현재 진행되고 있는 GOCI 검보정 연구를 통해서 복사, 대기, 해양환경 알고리즘에 대한 문제점이 도출되었고, 차후 검보정 계획에 반영하여 이 부분들에 대한 개선 및 보완이 이루어질 것으로 판단된다.

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

Rocket Measurement of Ozone Concentration Using KSR-420S

  • Lee, Ki-Young-;Lee, Dong-Hun-;Kim, Jhoon-;Park, Chang-Joon-
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1992년도 한국우주과학회보 제2권1호
    • /
    • pp.18-18
    • /
    • 1993
  • The first sounding rocket in Korea, KSR-4205 has been under the development at Korea Aerospace Research Institute (KARI), and is expected to be launched in 1993 to measure the vertical ozone profile over the Korean Peninsula. The KSR-4205 is expected to provide the first in situ meastulement of ozone concentrations over the Korean Peninsula. An optical ozone detector has been developed at Korea Research Institute of Standards and Science (KRISS), and its calibration has been completed recently. Also, sun-sensor has been developed for measurement of the angle between the sun and the KSR-4205. In this paper, measurement principles of the ozone detector in KSR-4205, its calibration data, ozone measurement procedure and data reduction algoriHun are presented with sample calculations.

  • PDF

공공측량 적용을 위한 비측정용 카메라의 현장자체검정 및 수치 입체 도화 (In-situ Self-calibration of Non-metric Camera and Digital Stereo Plotting for Public Survey)

  • 서상일;이병길
    • 한국측량학회지
    • /
    • 제35권3호
    • /
    • pp.145-154
    • /
    • 2017
  • 최근 건설, 도시계획 등 다양한 분야에서 1/1,000 수치지형도 제작에 대한 수요가 증가하고 있다. 이에 따라 고가의 항공사진측량 장비를 대체하는 저가의 비측정용 카메라 활용이 요청되고 있다. 국내에서도 좁은 대상지역을 비측정용 카메라로 촬영하여 대축척 수치지형도를 제작하기 위한 연구가 지속적으로 수행되고 있다. 그러나 비측정용 카메라 정확도의 한계로 입체사진을 이용한 수치도화는 어려운 상황이다. 본 연구에서는 비측정용 카메라를 공공측량에 활용하기 위해 대축척 수치도화 가능성을 검증하고자 하였다. 이를 위해 비측정용 카메라를 이용하여 수치도화한 성과와 지도제작용 DMC카메라를 이용한 성과의 정확도를 비교분석하였다. 표준부가매개변수 8개를 포함한 현장 자체검정을 수행한 후 1/1,000 축척으로 도화한 결과 RMSE가 평면 ${\pm}0.145m$, 표고 ${\pm}0.153m$로 공공측량 정확도에 적합한 것을 확인하였다.

불포화 토양내에서 가스상 오존 측정을 위한 광섬유센서의 적용

  • 정해룡;최희철
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.111-114
    • /
    • 2003
  • A new monitoring system has been developed for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone was obtained by converting the normalized intensity into ozone concentration. The FOTDP system reflected the ideal transport phenomena of gas phase ozone at various flow rates. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of SOM. However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

  • PDF

현장관측용 분광 광도계의 상대 검교정 시스템 개발 (Development of relative radiometric calibration system for in-situ measurement spectroradiometers)

  • 오은송;안기범;강혁모;조성익;박영제
    • 대한원격탐사학회지
    • /
    • 제30권4호
    • /
    • pp.455-464
    • /
    • 2014
  • 천리안해양관측위성(Geostationary Ocean Color Imager, GOCI)이 2010년 6월에 발사된 이후, 영상 자료의 보정과 검증을 위한 여러 차례의 현장 관측이 한반도 주변에서 수행되었다. 한국해양과학기술원 해양위성센터(Korea Ocean Satellite Center, KOSC)에서는 Analytical Spectral Devices (ASD)사의 분광 광도계 FieldSpec3나 TriOS사의 분광 광도계 RAMSES와 같은 현장관측장비의 특성 변화를 확인하기 위하여 미국국립표준기술원(National Institute of Standards and Technology, NIST)의 표준화 절차를 거친 광원과 표준 분광 광도계를 이용하여 각각의 현장 관측 마다 기기의 성능을 측정하였다. 본 논문에서는 해양위성센터에 구축된 광학 실험실과 현장관측 분광 광도계의 상대적 복사 검교정 방법에 대해서 소개하고 있다. 광학 실험실은 98% 이상의 광원 균질성을 지니는 20인치 적분구(USS-2000S, LabSphere)와 360 nm 부터 1100 nm 까지 1.6 nm 파장 간격으로 측정이 가능한 표준 분광 광도계(MCPD9800, Photal), 그리고 ${\pm}0.1mm$의 편평도를 가지는 광학테이블($3600{\times}1500{\times}800mm^3$)을 기본으로 구성되어 있다. 실험실 내부는 정확한 검교정 실험을 위하여 일정한 온습도를 유지하고 있으며, 동일한 광원에 동일한 위치에서 표준과 현장관측용 분광 광도계를 동시에 측정하는 방법을 기본으로 한다. 해양위성센터가 보유하고 있는 ASD 를 측정한 결과, 현장관측용 분광광도계의 결과가 푸른 가시광 영역에서 미세한 차이가 측정 시 마다 나타나는 것을 확인하였고, 더불어 1년간의 상대 검교정 실험에 따르면 평균적으로 4.41% 정도의 파장별 광특성이 변화하는 것을 확인하였다. 이러한 결과는 측정 정확도를 유지하고, GOCI 자료의 신뢰도를 확보하기 위하여 지속적인 검교정 실험을 수행해야 하는 이유를 보여주고 있다.

물리검층에 의한 파쇄대 인식과 동적 지반정수의 산출 (Application of geophysical well logging to fracture identification and determination of in-situ dynamic elastic constants.)

  • 황세호;이상규
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 1999년도 제2회 학술발표회
    • /
    • pp.156-175
    • /
    • 1999
  • 물리검층은 최근에 토목지반조사분야에 대한 활용성이 증가하고 있다. 이것은 물리 검층이 시추공 내에서 분해능 높은 다양한 원위치 물성정보를 제공할 수 있는 장점이 있기 때문이다. 현재 토목지반조사분야에서 적용되고 있는 것은 주로 암상구분, 파쇄대 인식과 동탄성계수의 산출, 지하수흐름검층 등이다. 이와 관련하여 최근에 활용성이 증가하는 물리검층법에 대한 소개와 지반조사와 관련한 물리검층 사례, 그리고 완전파형음파검층에 의한 탄성파 속도와 암반분류와 관계에 대한 사례를 소개한다.

  • PDF